No. 1588 Wangyuan South Road, Fengxian District, Shanghai
The sanitary napkin absorption speed tester consists of a standard testing module, an arc-shaped sample holder, an automatic liquid addition device, and an automatic timer
detailed introduction
(1)Sanitary napkin absorption speed tester product introduction:
The sanitary napkin absorption speed tester consists of a standard testing module, an arc-shaped sample holder, an automatic liquid addition device, and an automatic timer. The specific parameters are as follows:
(1)Standard testing module: Size Wei(76 ±1)mmX(80±1)mm,The quality is(127.0±)2.5g;
(2)Arc shaped specimen holder: length is(230±1)mm,Width is(80±)mm;
(3)Automatic liquid addition device: The amount of liquid added is(5.0±0.1)mL,Discharge speed less than or equal to3s;
(4)Automatic timer:resolution is0.01s.
(2)Test materials: standard synthetic test solution, distilled water or deionized water
(3)Detection principle: The sanitary napkin is adhered to the curved sample seat of the absorption speed test competition. The standard testing module is placed on the absorption area of the sample surface. The automatic liquid addition device adds a certain volume of standard synthetic test solution to the standard testing module. The timer records the time when the sanitary napkin completely absorbs the standard synthetic test solution, indicating its absorption speed.
The supplied components and materials have been inspected and tested to ensure no defects or flaws, and they will function properly when installed and operated correctly on the manufactured instruments. component(Excluding consumable components such as light sources, optical components, friction fabrics, etc)The warranty period starts from the date of shipment6A month.

This warranty replaces any other express or implied warranties. In any case, it is the responsibility and obligation to be liable for any special or indirect damages caused by a violation of this warranty clause.
The responsibility is limited to providing repair or replacement for any defective parts generated during the delivery process on board and at the factory. Damage to components caused by abuse, improper use, accidents, changes, neglect, unauthorized repair or installation will not be covered by warranty. There are reasons for identifying defects and their causeszuiFinal decision-making power.
The right to make changes and improvements to its products is reserved, but there is no obligation to perform improvements and installations on products already produced.
1.4 operating environment
This instrument is used in residential, commercial, and light industrial environments, following standardsBS EN 50081-1andBS EN50082-1
1.5 climate environment
The right to make changes and improvements to its products, but not the obligation to perform improvements and installations on already produced products.
This instrument operates under the following conditions:
altitude<2000m
Operating temperature:13~30℃(56~86℉)Relative humidity25~75%
Storage temperature:10~43℃(50~110℉)Relative humidity20~80%