The NE3941/NE3941E bearing vibration transmitter (speed) can provide dynamic signal output. The installation and debugging of the transmitter are convenient, with excellent frequency response characteristics, high measurement accuracy, good stability, and long service life; And it is equipped with high temperature impact protection, overload protection, reverse connection protection, and lightning protection; Multiple vibration range options are available; Optional wiring options include two wire, three wire, four wire, etc
NE3941/NE3941E Bearing Vibration Transmitter (Speed)Can provide dynamic signal output. The installation and debugging of the transmitter are convenient, with excellent frequency response characteristics, high measurement accuracy, good stability, and long service life; And it is equipped with high temperature impact protection, overload protection, reverse connection protection, and lightning protection; Multiple vibration range options are available; Optional wiring options include two wire, three wire, four wire, etc
Main technical indicators
Frequency range: Low frequency low-end frequency 0.2Hz (-3db)
Displacement: X 0.2Hz-30Hz; Speed: V 0.2Hz -1000Hz
Sensitivity: Speed (5Hz) V: 20mV/mm.s-1 (± 2%)
Displacement X: 8mV/um or 5mV/um (± 2%)
Range: Displacement ± 1.5mm
Linear error: ≤ 5%
Frequency response error: ≤ 5%
Maximum output voltage: 8V
Supply voltage ± 12VShaft vibration transmitterMain functions:
Installation of vibration sensor:
1. The VS type sensor adopts a sealed structure and comes with a protective cover. Except for environments with particularly high temperatures, there is no need to install a protective cover on the outer layer of the sensor in other situations.
2. Installation position: In principle, it is required to be installed in the position where vibration occurs during normal operation. A standard ordinary thread of M10 × 1.5mm with a depth of 10mm should be drilled into the installed tile cover. The sensor should be fixed to the measured point with a double headed screw of M10 × 1.5mm at the bottom of the sensor. During installation, the sensor must be kept horizontal or vertical to ensure its proper functioning.
3. The sensor shielding layer is single ended grounded, and it should be suspended and not connected to any part of the sensor, including the housing, to effectively avoid interference with the sensor.
4. During installation, attention should be paid to the connection of sensor connectors to avoid strong twisting or collision of wires.Directly install it in the original position where the preamplifier was placed
?
The ideal supporting product for computer data acquisition systems.On the basis of this, a backlit LCD screen is added to display the effective value of vibration velocity or peak to peak value of vibration displacement through the LCD screen. It also has a standard 4-20mA current output and can be directly connected to DCS, PLC or other equipment, truly realizing the "sensor ten monitoring instrument" vibration monitoring function. This product is easy to observe on site, has excellent performance, and is relatively affordable compared to vibration monitoring instruments. It is an ideal choice for factory equipment vibration measurement and monitoring.