1、 Application scope: Used for carbon and sulfur analysis in ores, soils, raw coal, coke, petrochemicals, and carbon element analysis in water

Product Details

1Application scope:

Used for carbon and sulfur analysis in ores, soils, raw coal, coke, petrochemicals, and carbon element analysis in water. This analyzer is a versatile, reliable, high-precision, and accurate analytical instrument. It can not only measure the total carbon and total sulfur in the sample, but also measure the different forms of carbon and sulfur components present in the sample. If carbon in elemental carbon, organic carbon, and carbonate can be measured separately; Sulfur in elemental sulfur, sulfide sulfur, and sulfate.

IITechnical Specifications

1.Analysis scope: Carbon:0.0001-100%

Sulfur:0.0001-100%

2.Minimum reading carbon:0.00001%Sulfur:0.00001%

3.Instrument accuracy: meets the national standards for analyzing corresponding materials

4.Correction method: single point or multi-point correction

5.Injection method: automatic injection

IIIEquipment configuration and parameters

1.High temperature combustion furnace: output power,4KW

2.Heating temperature:300-1300℃(Adjustable)

3.Electronic balance Mettler weighing range of one ten thousandth0.1mg-100mg

4.Computer Founder's current mainstream configuration in the market

4、 Analysis speed

Single sample analysis is generally used1-3Minutes, maximum for special materials5minute.

5Equipment working conditions:

power supply220V±5%,50Hz±1%,

Single-phase communication; Single phase AC voltage stabilizer5KVA)

Indoor temperature:10-35℃;

Relative humidity: ≤75%

When the device can maintain its working performance for a long time and stably in the above working environment.

6、 Infrared analyzer

1Detection pool: usingdoubleDetection pool(Carbon poolSulfur pool

2The detection part adopts an independent data acquisition system and an independent digital to analog converter; The sampling frequency is12.5time/In seconds.

3Integrated low-power light source chamber, low-power platinum light source, constant temperature chamber, (patent applied, patent number).6)High precision flow controller, narrowband filter and infrared pyroelectric solid light cone sensor, high-precision imported synchronous cutting motor, (patent applied, patent number).1)Pre amplification,continuous work10Ten thousand hours without any malfunctions,sampling frequency12.5time/In seconds,A/DData collection.

4Passive constant current system, free replacement within ten years1-2Next time. (Patent applied for, patent number).4)

5、The flow control system adopts high-precision flow control devices to ensure that the flow is not affected by temperature, pressure, or changes in gas composition in the gas path. The gas path system is designed to be simple and has good airtightness. The cylinder, gas path, solenoid valve, and joints are made of world-renowned brands. Free maintenance10Years or more.