Shanghai Quli Automation Technology Co., Ltd.: Siemens CNC system servo motor maintenance is a complex technical service industry. In recent years, servo motors have been used more and more widely, and the use of the market in Chinese Mainland has increased rapidly. The demand for technical services such as spindle motor maintenance has become increasingly urgent. Due to the fact that most of the servo motors used in China are imported products with high technological content, foreign servo motor manufacturers have adopted non-standard encoders or installation methods in order to monopolize the maintenance service market, making spindle motor maintenance more difficult and forming servo motor maintenance as an outstanding technical skill.
Professional maintenance of various brands of servo motors for repair faults: magnet explosion, magnet detachment, stuck rotation, encoder wear, code disk/glass disk wear and tear, motor overheating, motor water ingress, motor abnormal operation, high-speed operation noise, loud noise, brake failure, brake pad wear, low-speed normal high-speed deviation, high-speed normal low-speed deviation, start alarm, start trip, overload, overvoltage, overcurrent, unable to start, weak start, operation shaking, demagnetization, running position, walking deviation, output imbalance, encoder alarm, encoder damage, inaccurate position, alarm when powered on, tripping when powered on, driver server alarm code, burnt coil winding, aviation plug damage, incorrect origin position, encoder debugging/zero adjustment. Replacing bearings, bearing groove wear, rotor fracture, Shaft fracture, gear groove wear, etcCommon troubleshooting methods for Siemens servo motor maintenance
Common troubleshooting methods for Siemens servo motor maintenance
Siemens servo motor maintenanceIt is a common problem encountered in daily life. A servo motor refers to an engine that controls the operation of mechanical components in a servo system, and is an indirect variable speed device that supplements the motor. This motor can achieve very accurate control speed and position accuracy, and can convert voltage signals into torque and speed to drive the controlled object. Compared with single machine asynchronous motors, servo motors have three significant characteristics: high starting torque, wide operating range, and no self rotation phenomenon.
Siemens servo motor maintenanceWhat are the common faults? What is the solution?
1、 Motor overcurrent and overload alarm
Improper installation of the motor and excessive mechanical load can cause overload alarms.
Solution: Install correctly to reduce mechanical load;
2. The motor is flooded with water. The insulation of the motor stator coil to ground is less than 10M Ω, and the power socket is short circuited between phases.
Solution: The insulation resistance of the cleaned and dried stator should be greater than 100M Ω. If it does not meet the requirements, replace the power socket or motor stator as needed;
2、 Motor overheating alarm (430 alarm)
1. Encoder detection error. Solution: Replace the encoder with a new one. Can be completed by users and on-site maintenance engineers;
2. Temperature sensor detection error, temperature sensor damaged. The normal value should be between 55-80k Ω, and the resistance value varies with the ambient temperature. Solution: Send the motor back to the company for repair;
Improper installation of the motor and excessive mechanical load can cause overheating alarms. The solution should be correctly installed to reduce mechanical loads;
4. The brake coil of the motor with brake is short circuited or open circuited. The brake is not opened, causing excessive load on the motor. The reason is due to inaccurate voltage capacity provided to the brake coil. The brake cannot be fully appliedOpen it. Solution: Replace the brake and equip it with an independent power supply. The resistance of the alpha series motor brake coil is about 230 Ω, and the coil voltage is 90V. The resistance of the α i series motor brake coil is 26 Ω, and the coil voltage is 24V.
Alright, the above is the introduction to the maintenance of Siemens servo motors.
Siemens low-voltage AC asynchronous motor 1LG0 series maintenance; Siemens efficiency enhanced 1LA7, 1LG4, 1LG6 series maintenance, Siemens high-power motor 1LA4, 1LLA8, 1PQ8 series maintenance, Siemens 1LA9, 1LG6 series motor maintenance, Siemens increased safety explosion-proof 1MA6, 1MA7 series motor maintenance, Siemens explosion-proof 1MJ6, 1MJ7 series motor maintenance; Siemens tobacco specific 1LA7, column motor maintenance, Siemens servo motor 1FK7, 1FT6, 1PH7 series motor maintenance, Siemens DC motor 1GG5, 1GG6 series motor maintenance, Siemens 1PH series spindle motor maintenance. Common faults of servo motors; Power on alarm, overload, overvoltage, overcurrent, unable to start, unable to start. Operation shaking, demagnetization, displacement, output imbalance, encoder alarm, encoder damage, inaccurate braking position, magnet explosion and stuck rotation, motor overheating, abnormal motor operation, loud noise during high-speed operation, brake failure and other repairs. Professional Siemens servo motor drive maintenance center SIEMENS CNC 611611E drive maintenance, 6SN1145 maintenance, 6SN1146 maintenance, 6SN1118 maintenance, 6SN1123 maintenance, our company's professional maintenance, module explosion, low output voltage, red light on, no display, missing phase, complete accessories, reasonable price.
The 840D system built by the company can test the 1145, 1123, 1146, 1124, and 1118 series accessories used on 810D, 802D, 802C, and 802S systems. Siemens driver 6SN1123, 1124 fault maintenance alarm code: 1. Overcurrent (common 607, 608 alarms) maintenance. 2. Overload repair, 3. Alarm: # 605, # 606, # 607, # 608, contour alarm, # 039 repair. #300500, 300501, 300502, 300503, 300504 4. When the drive cannot be used, it can still be used after a period of shutdown, but the usage time is getting shorter and shorter. It needs to be repaired immediately, otherwise the drive module will burn out