DN150 Vortex Flow MeterThe manufacturer of the production quotation for this flowmeter product model belongs tovortex flow meterClassification, more vortex streets DN150、 Welcome to inquire about the direct sales price quotation of the flow controller. Below is the product information and details of the DN150 vortex flow meter.
DN150 flowmeterLow pressure loss, wide range, high accuracy, and almost unaffected by fluid density, pressure, temperature, viscosity, and other parameters when measuring volumetric flow rate under working conditions. The DN150 vortex flowmeter can be directly used in conjunction with intelligent flow integrators, as well as with computers and distributed systems, to measure flow parameters of different media. This instrument has the characteristics of simple structure, good universality, and high stability Stress type vortex flowmeter can be used for various flow detection and measurement.

1Characteristics of DN150 Vortex Flow Meter:
1. Accurate measurement of gas, liquid, and vapor flow rates over a wide range of flow rates without being affected by fluid physical properties;
2. Not affected by temperature and pressure, and not easily clogged, stuck, or scaled, resistant to high temperatures and pressures;
3. Safe and explosion-proof, suitable for harsh environments;
4. No movable parts, no holes or gaps design, the product is wear-resistant, dirt resistant, does not require mechanical maintenance, and has a long service life;
5. Adopting low-power high-tech and battery powered on-site display flowmeter, it can operate continuously without electricity for more than two years;
6. Integrated design of temperature and pressure compensation;
7. The current output is all electrically isolated, with good common mode interference suppression capability;
8. Simultaneously display the flow value and cumulative flow value, without the need to switch between them;
9. Adopting anti vibration probes to effectively eliminate the influence of external vibrations;
10. Adopting a split type signal converter with a maximum cable length of 100 meters;
11. The range ratio is up to 20:1;
12. The overall structure design of the instrument is reasonable, with a wide dynamic measurement range and low pressure loss;
13. The body is made of stainless steel material, which is suitable for measuring corrosive media;
14. On site LCD display, pulse, 4-20mA output or 485 communication, can be connected to industrial automation systems.
IITechnical parameters of DN150 vortex flowmeter:
Measuring fluids: steam, mixed gases, liquids
Measurement accuracy and repeatability:
Measurement of fluid accuracy and repeatability
Gas (including steam) 1.0 grade 0.33%
Liquid grade 1.5 0.5%
● Measurement range
Measure the lower limit of fluid flow velocity (m/s) and the upper limit of flow velocity (m/s)
Gas (including steam) 7 70
Liquid 0.7 7
●额定压力: 1.6MPa、2.5MPa、6.3MPa
Fluid temperature: -40 ℃~250 ℃ (ordinary type), 100 ℃~350 ℃ (ordinary type)
● Structural type: Integrated flowmeter
● Structural material
Component Name Material
Sensor body made of 304 stainless steel and 316 stainless steel
The body is made of 304 stainless steel and 316 stainless steel
Detection probe 316L
Connecting rod made of 304 stainless steel
Aluminum alloy radiator
High temperature resistant asbestos pad, nitrile rubber pad, graphite pad
● Working power supply
*3.6V lithium battery power supply (local display type)
The second power supply method is 24VDC (or 12VDC)
The second power supply method is 24VDC (or 12VDC) or 3.6V lithium battery dual power supply

IIIInstallation method of DN150 vortex flowmeter:
1. The installation position should be selected as much as possible in a location without pipeline vibration or with low vibration, and the vibration acceleration should not exceed 2g. If the vibration is large, vibration reduction measures need to be taken;
2. There must be sufficient straight pipe sections upstream and downstream of the high-temperature condensate flow meter;
3. The maintenance valve is installed upstream of the sensor, and the flow control valve is installed downstream of the sensor;
4. Try to choose a location that is easy to install and maintain;
5. Choose a location with a dry environment;
6. Sensors can be installed on horizontal or vertical pipelines. But when installed on a vertical pipeline, the medium must flow from bottom to top.
7. Sensors should be installed indoors as much as possible. When installed outdoors, attention should be paid to waterproofing, and cables outside the amplifier should be bent into a U-shape;
8. Sensors should be kept away from electrical noise, such as high-power frequency converters, high-power transformers, motors, and high-power wireless transceivers.

The above is the complete content of the vortex flowmeter DN150 flowmeter product. Welcome to call and inquire about the selection and quotation of the vortex flowmeter DN150 flowmeter.
This article address: Please do not delete when reposting! [DN150 Vortex Flow Meter]