Welcome Customer !

Membership

Help

Xi'an Datai Electronics Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

DTD433F | Multi point cluster networking wireless analog signal measurement and control terminal

NegotiableUpdate on 08/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Compliant with MODBUS RTU protocol, supports wireless networking of configuration software, wireless measurement of temperature, pressure, and flow, with a wireless transmission distance of up to 3 kilometers!

Product Details

Product Details

Compliant with MODBUS RTU protocol, supports wireless networking of configuration software, wireless measurement of temperature, pressure, and flow, with a wireless transmission distance of up to 3 kilometers!


Product Overview:

Technical service hotline:

The DTD433F wireless analog terminal is equivalent to a wireless transmitter with 4 analog inputs and 4 analog outputs. It provides 4AI and 4AO, complies with the MODBUS RTU protocol, and has a reliable wireless transmission distance of up to 3 kilometers.
The DTD433F product is suitable for point-to-point and dispersed applications that are not convenient for trench digging and wiring. The DTD433F can not only form wireless measurement and control systems with PLC, DCS, intelligent instruments and other devices, but also achieve configuration of Datai Free Protocol and MODBUS protocol with industrial control products such as configuration software, human-machine interface, touch screen, etc., providing a low-cost solution for medium to short distance wireless communication in the industrial measurement and control field.


Key features:

Technical service hotline:
◆ It can directly replace wired RS485 network, comply with standard MODBUS RTU protocol, and achieve analog wireless measurement and control;

◆ Analog input: 1-8 channel AI input, 0-5V voltage signal or 4-20mA current signal input;

◆ Analog output: 1-8 channel AO output, 4-20mA current signal output;

◆ Anti interference capability: Internally integrated industrial grade high anti-interference EMI unit.


Product Description:

Technical service hotline:

Wireless analog signal 4-20mA, wireless analog acquisition, wireless MODBUS RTU, wireless analog transmitter


Standard product selection:

On site analog quantity from equipment

◆ Control room main control equipment


Main features:
◆ Analog input: 1-8 channel AI input, 0-5V voltage signal or 4-20mA current signal input

◆ Analog output: 1-8 channel AO output, 4-20mA current signal output

◆ Can directly replace wired transmitters to achieve wireless sensor cluster networking

There are three options for effective wireless transmission distance: around 300 meters, 1000 meters, and 3000 meters

◆ Transmission method: fully digital wireless encrypted transmission

◆ DC wide voltage 9~24VDC power supply, with an average operating current of less than 50mA

◆ PVC plastic shell: 115 × 74 × 60mm, E-type guide rail slot installation

◆ Supports standard serial port protocols: Datai Free Serial Port Protocol, MODBUS RTU Protocol

The product is stable and reliable, and has been continuously used on industrial sites for more than ten years.


Customized solution:

Technical service hotline:

◆ 1 master station and 12 slave stations
The main station provides a 485 interface, and each slave station collects 8 switch signals.
◆ Three water level signals are collected from the top of the mountain, and the PLC Rs485 port at the bottom of the mountain outputs a 220V power supply
The main station has one DTD433MEY, and three slave stations each provide one analog signal input to DTD433FEY-T1AI.
◆ The slave station is a bidirectional mixed signal
The DTD433FHC-4022 substation provides 4 analog inputs, 2 switch inputs, and 2 switch output signals.
◆ 1 master station and 5 slave stations, which have both analog and switch signals
3 slave stations DTD433FC - collect analog signals, 2 slave stations DTD433HC - collect switch signals.


Application example:

The DTD433F industrial grade wireless analog terminal can directly replace wired transmitters and supports free serial port protocol and MODBUS RTU protocol; Thoroughly solve the problems of complicated construction and high maintenance costs of wired solutions. Can be directly configured with configuration software PLC、 Touch screen and smart instrument connection, no need for trench wiring, successful applications include:

Wireless DCS monitoring system for rubber factory vulcanization production process;

◆ Directly replace wired transmitters with 4-20mA to achieve wireless communication;

Factory renovation project, adding wireless sensor monitoring points at any time;

Wireless remote monitoring of pipeline pressure, temperature and humidity in industrial settings;

Real time wireless measurement and control of industrial equipment operating parameters.

Technical service hotline:




Typical application users:

Jinan Helishi Automation Engineering Co., Ltd

◆ School of Engineering, Air Force Engineering University

Beijing Tongfang Clean Technology Co., Ltd., one main and two secondary

Taiyuan Donglu Aluminum Industry Co., Ltd., one main and two secondary

Hubei Jinpai Liquor Industry Co., Ltd

Guilin Yanjing Beer

Jiangsu Fuyuda Grain Products Co., Ltd

Jiangsu Zhongre Machinery Equipment Co., Ltd

Jinan Great Wall Instrument Technology Co., Ltd

Suzhou Shuidu Environmental Company, PLC online control of liquid level, pressure and other signals

Jiangsu Tianyi Xinde Environmental Protection Technology Co., Ltd., one owner and multiple followers

Hebei Luanping Huadu Food Co., Ltd

Shaanxi Xianyang Yanchang Xinghua Chemical Plant, 1 main and 3 auxiliary mixed signal monitoring system, 2 kilometers [Click to enter the plan]

◆ Hunan Meijing Environmental Protection Technology, Hydroelectric Power Station Reservoir Liquid Level Transmission Computer Year

◆ Fupaibock Polymer Materials (Changzhou) Co., Ltd., 8 PT100 instrument signals to PC

◆ Houma Sanxin Electrical Cable Co., Ltd., sensors to DCS

◆ Australian power plant, renovation of air preheater leakage gap control system, 3km [Click to enter plan]

Gongyi Beikong Water Co., Ltd. wirelessly transmits simulated signals from multiple dispersed points in the sewage treatment plant to the PLC, 2 kilometers away

Shougang Group Co., Ltd. relocated to the sintering plant of the steel company, with wireless communication between on-site sensors and PCs at a distance of 600 meters

Erdos Sugeli Gas Field Production Command Center, 15 temperature controllers with 485 data and upper computer software wireless communication, 300 meters

Changchun Wenyan Technology Development Co., Ltd., 4-20mA detection signal to touch screen, 500M

Suzhou Andisen Electrical Engineering Co., Ltd., 3 on-site sensor signals to Kingview, 500M


Related products:

■ DTD433H | Multi point cluster networking wireless switch signal measurement and control terminal

■ Master station equipment DTD433M - Industrial grade wireless communication data terminal

Point to point wireless analog signal transmitter


Product information: Please add QQ (1582866104) or WeChat () to request:

Technical service hotline: (same as WeChat)

  1. User Manual for DTD433F Series Wireless Analog MODBUS Measurement and Control Terminal

  2. DTD433F series wireless analog MODBUS measurement and control terminal communication protocol

  3. Siemens S7-200 and MODBUS Wireless Analog Measurement and Control Terminal Routine

  4. Configuration software for Kingview, Power Control, MCGS, and Jiekong and communication routine with DTD433F

  5. Wireless Measurement and Control Scheme for Analog Signal of DTD433F

Solution 1: Application Plan for Connecting Wireless Data Terminals with Wireless Measurement and Control Terminals

The host of this system uses a DTD433M wireless data terminal, which adopts RS485 or RS232 interfaces to connect with computers DCS、PLC、 Touch screen and other controllers can be connected, and MODBUS communication can be achieved through configuration software. The slave uses the DTD433H series switch wireless measurement and control terminal or the DTD433F series analog wireless measurement and control terminal to transmit MODBUS protocol data through wireless communication.

Scheme 2: Wireless MODBUS Communication Scheme between Touch Screen, Configuration Software and DTD433F

In practical systems, touch screens, human-machine interfaces, and monitoring objects are not located together. The central computer is usually placed in the control room, while the fault point or controlled equipment is installed in the on-site workshop, and the distance between the two often ranges from tens of meters to thousands of meters. If wiring is required, trench excavation construction is needed, which is quite troublesome. In this case, wireless communication is more suitable. Because the use of wireless MODBUS protocol does not require complex programming, only simple configuration is needed. To achieve wireless MODBUS communication, specialized wireless data terminals are required, and the matching of setting parameters should also be considered during configuration. The principle of MODBUS wireless communication in Kingview and force control configuration software is shown in the figure.