•Measurement parameters
|
Measurable active, reactive, forward active, reverse active, forward reactive, reverse reactive, four quadrant reactive and other electrical quantities.
|
•Monitored Parameters
|
Can monitor real-time values of voltage and current in each phase, and can monitor real-time parameters such as active power, reactive power, power factor, phase angle, and phase of the three-phase total and A, B, and C phases.
|
|
•Time sharing metering function
|
Time division metering of forward and reverse active power, four quadrant reactive power, and maximum demand. Data storage function: Time division metering of active and reactive electricity, capable of storing 12 months of historical electricity data.
|
•Data storage function
|
Time division metering of active and reactive power, capable of storing historical electricity data for 12 months..
|
|
•Load curve function
|
Capable of recording load curves for 6 types of data; You can freely choose to draw a curve graph from data such as voltage, current, frequency, power and power direction, power factor, total reactive power, four quadrant reactive power, current demand, etc.
|
•display function
|
Wide viewing angle, large screen LCD display, with rich status indication and Chinese character auxiliary prompt information; It can display the monthly electricity consumption data for the past three months.
|
•Anti electricity theft function
|
It has the function of recording events such as opening, voltage loss, current loss, phase failure, current imbalance, power failure, reset, reverse phase sequence, and reverse power being included in the forward power, to prevent users from illegally removing or cutting off voltage and current connections; Monitor the operation status of the electricity meter.
|
|
•Data output and communication functions
|
RS485 communication port and carrier communication interface for meter reading, in conjunction with the meter reading system, can read various electricity data from the meter. And supports DL/T645-2007 multifunctional energy meter communication protocol.
|
•Cost control function
|
Using RS-485 and carrier power line for data communication; Without IC card mount, supports remote communication for opening and closing.
I can remotely control the opening and closing of the electric energy meter and set parameters such as time periods, thereby implementing remote management of users' electricity consumption.
II can achieve automatic deduction and payment functions, as well as functions such as overdue tripping. When the electricity bill of the meter is insufficient, it can be remotely alarmed. When there is no electricity bill, it can be remotely tripped and powered off, making operation and management very convenient.
|