E-mail
945682112@qq.com
-
Phone
15189528755
-
Address
No. 359 Shenhua Avenue, Jinhu County Industrial Park
Jinhu Hengchuan Instrument and Meter Complete Set Factory
945682112@qq.com
15189528755
No. 359 Shenhua Avenue, Jinhu County Industrial Park
1、 Product Introduction:
HC-HLV seriesDelta flowmeterThe full name of the model isHC-HLV-FC-P100C-LP-MT-DH-WXN.
HC-HLV seriesDelta flowmeterIt is a flow sensor designed using differential pressure working principle and plug-in installation method. Its working principle is a special throttling device, and its output is differential pressure. The sensor measures pressure through a probe (or probe), which has two rows of unevenly distributed pressure tapping holes in front and behind the probe (the diameter of the pressure tapping tube is about Φ 20, and the low-pressure aperture of the pressure tapping hole is Φ 8). By averaging the different pressures (flow rates) of the pipeline from top to bottom (left to right) through two rows of pressure holes, a differential pressure is formed, which can be used to calculate the mass flow rate or volume flow rate.
2、 Product scope of application
1. Nominal diameter: 25mm ≤ DN ≤ 6000mm2. Nominal pressure: PN ≤ 25MPa3. Medium temperature: t ≤ 650 ℃4. Accuracy level: 0.5111 level, 1 level, 1.51111 level
3、 Structural form
HC-HLV seriesDelta flowmeterIt is composed of a detection rod and a pressure tap, which crosses the inside of the pipeline perpendicular to the pipeline axis. There are multiple total pressure detection holes on the upstream side of the detection rod, and multiple static pressure detection holes on the downstream side of the detection rod, which are respectively led out by the total pressure conduit and the static pressure conduit. Based on the differential pressure value between the total pressure and static pressure, the flow rate through the pipeline is calculated.theoretical basisHC-HLV seriesDelta flowmeterIt is developed based on the principle of pitot tube speed measurement, which determines the flow rate by multiplying the average flow velocity of the pipeline and the effective cross-sectional area of the pipeline.1. Probe cross-sectional shape: The delta bar is a rhombus like shape, which can make the boundary between high and low areas more distinct.2. The position of the pressure hole on the probe rod: the full pressure hole with high power is located at the front end of the rod, and the static pressure hole is located on both sides of the rod wall;Delta flowmeterThe full pressure hole is also located at the front end of the rod, but the static pressure hole is located at the back end of the rod to measure the back pressure (negative pressure).Therefore, under the same pipe diameter and flow rate conditions, the differential pressure generated by the Delta probe is slightly larger than that of the Weiliba probe, about 20% -40% larger. This isDelta flowmeterSignificant advantages.
4、 Installation method and requirements