Design scheme for hydraulic pump station system for billet forming/Focused on non-standard hydraulic equipment for decades, can process and produce according to drawings and samples, industrial equipment hydraulic station, hydraulic cylinder Hydraulic press consultation hotline: Shanghai Ziying Hydraulic Equipment Co., Ltd
Circulating flushing device for hydraulic system
The circulating flushing device generally uses an independent high flow high-pressure flushing device or a system's working pump station for pipeline circulating flushing operations. The output flow rate of an independent high flow high-pressure flushing device is generally above 1000 liters per minute, and should consist of 3-4 high-pressure pumps and 1 low-pressure pump. According to the parameters of the metallurgical hydraulic system, the high-pressure pump (31.5MPa) flow configuration can be configured with 250 liters per minute, 160 liters per minute, 100 liters per minute, 63 liters per minute, and low-pressure pump (2.5MPa) 400-600 liters per minute to meet the needs of different flushing pressure and flow rates.
The output pipeline interface of the circulating flushing device should be able to simultaneously flush one flushing circuit with the output flow of all flushing pumps, or form multiple independent flushing circuits for simultaneous flushing.
The use of the system's own working pump station for pipeline circulation flushing operations has also gained widespread application and recognition. Using a working pump station to flush system pipelines is an efficient and reliable method for achieving flushing quality quickly, and has more advantages. Specifically, it saves valuable time and saves a lot of temporary piping materials. The formal electrical protection of the working pump station itself and the circulation cooling and internal circulation filtration functions in the system can be utilized to make the system flushing effect of the pipeline better and faster.