OverviewDifferential pressure flowmeter for high-temperature flue gas of coke oven blast furnace gas
The V-cone flowmeter is a new type of throttling device that combines the advantages of the classic Venturi tube and annular orifice plate. Its theoretical principle is based on the Bernoulli equation of energy conservation and the flow continuity equation in a closed pipeline. Under stable flow conditions, the flow velocity in the pipeline is proportional to the square root of the differential pressure. The V-cone flowmeter has good stability, high accuracy, good repeatability, wide range ratio, low requirements for installation pipe sections, and small pressure loss. It can measure fluids containing particles, low-pressure fluids, high humidity gases, and various dirty fluids.
Scope of applicationDifferential pressure flowmeter for high-temperature flue gas of coke oven blast furnace gas
1. Nominal diameter: 15mm ≤ DN ≤ 1800mm
2. Nominal pressure: PN ≤ 40MPa
3. Reynolds number range: 5 × 10 3 ≤ ReD ≤ 10 7
4. Accuracy level: 0.5 level, 1 level
5. Length of straight pipe section: Front 1-3D, Rear 0-1D
6. Applicable media: various media such as gas, liquid, steam, etc
7. Aperture ratio: β=0.3-0.75
8. Maximum temperature: 540 ℃
9. Repetition accuracy: ± 0.1%
10. Range ratio: 15:1
structural form
The specific external structure is shown in the following figure: