JY-210WSeries eddy current sensors
Overview of JY-210W seriesEddy current displacement sensorThe basic working system consists of the tested object, probe, extension cable, and preamplifier. The preamplifier generates high-frequency oscillating current that flows into the probe coil through an extension cable. The coil generates an axial magnetic field. When the measured metal body approaches this magnetic field, eddy currents are generated on the surface of the measured metal (the strength of the eddy currents varies with the distance between the probe and the surface of the measured body), thereby causing the coil toQValue changes. When the distance is small, the eddy current effect is strong, and the coilQSmall value; When the distance is large, the eddy current effect is weak, and the coilQThe value is high. In practical applications, the coilQThe change in value is detected and amplified by the preamplifier, and converted into a change in voltage. Realize the mechanical displacement(gap)Convert the value into a voltage value.
1. Technical Specifications:
● power supply-24VDC±10%
● Frequency response:DC~5 kHz
● Resolution:1um
● Probe sensitivity error: ±3%
● Probe linear error: ±1%
● Operating Temperature
Probe operating temperature:-30℃~120℃ (can work normally within this temperature range)
Cable operating temperature:-30℃~120℃ (can work normally within this temperature range)
Operating temperature of preamplifier:-30℃~80℃
● Overall dimensions:80 mm×60mm×30mm
● Installation method: Installation adopts guide rail installation
2. Measuring range:
at room temperature25℃, tested material45#steel,power supply-24V±10%, load10KUnder the condition of Ω, satisfy:
Probe diameter(mm) |
linear range(mm) |
linearity |
sensitivity |
Sensitivity error |
(v / mm) | ||||
F5 |
1 |
±1% |
8 |
2% |
F8 |
2 |
±1% |
8 |
2% |
F11 |
4 |
±1% |
4 |
2% |
F25 |
10 |
±1.5% |
0.8 |
3% |
3Selection instructions:
JY-210Selection guide for series eddy current sensors:
(1) Probe selection instructions:
JY-210T-A□□-B□□-C□□-D□□-E□□-F□□
AProbe diameter |
BProbe without thread length |
CProbe thread length |
DProbe thread specification |
Ecable length |
FMetal armor |
||||||
05 |
5mm |
00 |
0mm |
50 |
50mm |
G1 |
M10*1.0 |
10 |
1.0m |
00 |
Unarmored |
08 |
8mm |
05 |
5mm |
30 |
30mm |
G2 |
M14*1.5 |
05 |
0.5m |
01 |
Armored |
Fill in according to actual size |
Fill in according to actual size |
Fill in according to actual size |
G3 |
M30*2.0 |
90 |
9m |
|||||
TT |
Special Orders |
TT |
Special order |
TT |
Special order |
TT |
Special order |
TT |
Special order |
||
(2) Extension cable selection instructions:
JY-210Y-A□□-B□□
Acable length |
BMetal armor |
||
40 |
4m |
00 |
Unarmored |
45 |
4.5m |
01 |
Armored |
80 |
8.0m |
||
85 |
8.5m |
||
TT |
Special order |
||
(3) Selection instructions for preamplifier
JY-210Q-A□□-B□□-C□□-D□□
ADiameter range |
Boutput characteristics |
Cpower supply |
DTotal length of cable |
||||
02 |
2mm |
V0 |
-2~-18V |
P1 |
-24V |
M1 |
5msystem |
10 |
1mm |
I0 |
4~20mA |
P2 |
24V |
M9 |
9msystem |
04 |
4mm |
V1 |
1~5V |
TT |
Special order |
TT |
Special order |
08 |
8mm |
V2 |
1~10V |
||||
10 |
10mm |
V3 |
0~5V |
||||
TT |
Special order |
TT |
Special order |
||||