E-mail
DS13564775333@163.com
-
Phone
13564775333
-
Address
1908 Liuxiang Road, Malu Town, Jiading District, Shanghai
Shanghai Huquan Valve Group Co., Ltd
DS13564775333@163.com
13564775333
1908 Liuxiang Road, Malu Town, Jiading District, Shanghai
一、 j941y-16c dn80Electric regulating flange cast steel globe valvesummary:
Electric flange regulating cast steel globe valveIt has good strength, rigidity, and flow capacity, and is composed of an electric actuator and a flange stop valve. It receives AC380V power pressure or voltage signals to complete the opening and closing actions of rising or falling. Electricity can be used in various pressure, temperature, and medium conditions, widely used in pipelines in environmental protection, petroleum, chemical, and power industries with nominal pressures ranging from PN1.6 to 16MPa and working temperatures ranging from -29 to 550 ℃. It plays a role in cutting off fluids and is suitable for both fully open and fully closed forms.

二、 j941y-16c dn80Electric regulating flange cast steel globe valveProduct Features:
(1) Compact structure, reasonable design, good valve rigidity, smooth channel, and low flow resistance coefficient.
(2) The sealing surface is made of stainless steel and hard alloy, with a long service life.
(3) Using flexible graphite packing, reliable sealing, and easy and flexible operation.
3、 Technical parameters:
1. Power supply: The motor is three-phase AC, 380V (special order 660V or 220V), 50Hz (special order 60Hz); The control line is 220V, 50Hz (special order 60Hz); Remote control is 24VDC.
2. Ordinary and outdoor types are used in places without flammable/explosive and non corrosive media; There are two types of explosion-proof products, dI and dIIBT4. dI is suitable for non mining working faces in coal mines; DIIBT4 is used in factories and is suitable for explosive gas mixtures in IIA and IIB level T1 to T4 environments.
4、 Main component materials and main uses:
Nominal diameter DN (mm) |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
300 |
||||
(10) |
(12) |
(15) |
(20) |
||||||||||||||
Rated flow coefficient Kv |
straight line |
1.8 |
2.8 |
4.4 |
6.9 |
11 |
17.6 |
27.5 |
44 |
69 |
110 |
176 |
275 |
440 |
690 |
1100 |
1760 |
equal percentage |
1.6 |
2.5 |
4.0 |
6.3 |
10 |
16 |
25 |
40 |
63 |
100 |
160 |
250 |
400 |
630 |
1000 |
1600 |
|
Rated travel L (mm) |
10 |
16 |
25 |
40 |
60 |
100 |
|||||||||||
Inherent flow characteristics |
Straight line, equal percentage |
||||||||||||||||
Inherent adjustable ratio R |
50:1 |
||||||||||||||||
Allowable leakage amount |
Hard valve seat: Grade IV, soft valve seat: Grade VI |
||||||||||||||||
Nominal pressure PN (MPa) |
1.6, 4.0, 6.4 |
||||||||||||||||
Working temperature t (℃) |
Room temperature type |
-20-200, -40 to 250, -60 to 250 |
|||||||||||||||
Heat dissipation type |
-40-450, -60-450 |
||||||||||||||||
high-temperature type |
450~560 |
||||||||||||||||
low-temperature type |
-60-100, -100 to -200, -200 to -250 |
||||||||||||||||