Overview
Introduction: The empty box pressure gauge calibration device adopts high-precision imported resonant pressure sensors to measure atmospheric pressure with high precision and resolution. It uses a 10.4-inch capacitive touch screen and WINDOW system, with strong expandability, and can stack various functions according to different requirements. The high-precision pressure gauge can display information such as atmospheric pressure, altitude, temperature, etc
Product Details
Introduction:
The empty box pressure gauge calibration device adopts high-precision imported resonant pressure sensors to measure atmospheric pressure with high precision and resolution. It uses a 10.4-inch capacitive touch screen and WINDOW system, with strong expandability, and can stack various functions according to different requirements. The high-precision pressure gauge can display information such as atmospheric pressure, altitude, temperature, etc.
Technical parameters:
Measurement range: 0hPa to 1200hPa
Accuracy level: 0.02 level (± 0.2hPa)
Resolution: 0.01hpa
Testing warehouse space: 400 * 400 * 800 (millimeters)
Temperature: 0-35 ° C
Working temperature: -10 ℃ to 40 ℃
Storage temperature: -30 ℃~50 ℃
Power supply: AC220V ± 22V, 2A
USB interface: 1
Page Introduction:


Rising and falling rate: unit hPa/min, can be controlled according to regulatory requirements to increase and decrease the pressure rate
Current altitude: Convert altitude information based on altitude and altitude table
Unit: Switch between different units, default is KPA PA hpa mbr inhg mmHg
Data: Display stored data, collected and stored once every 0.5S by default
Settings: Calibrate sensors and set airport altitude
Curve saving: Save the current curve in the "Image: Folder" on the desktop
Timing function: Record time, click the "Timing" function to start timing, click "Pause" to end timing, and clear the timing function,
Data storage and export:
Click on "Data" to view the data stage and no longer update atmospheric pressure data

Click on "Download List"

Prompt for successful download, now stored as an Excel file in the 'Download' folder on the computer desktop.