Product Introduction:
The Ex series explosion-proof laser gas analysis system adopts a positive pressure explosion-proof cabinet to isolate flammable substances from ignition sources, achieving explosion-proof purposes. The analysis system is based on the principle of tunable semiconductor laser absorption spectroscopy (TDLAS) technology, which scans and analyzes gas absorption spectral lines of specific wavelengths, and combines advanced technologies such as digital lock-in amplifiers and long path gas chambers to achieve gas concentration measurement. The instrument has the characteristics of high sensitivity, fast response speed, no background gas interference, non-contact measurement, etc., providing a reliable guarantee for real-time and accurate reflection of changes in the measured gas.

Product Features:
1. Spectral multi wavelength scanning without cross interference from background gases
2. Reliable long path detection cell design ensures measurement accuracy
3. Fast response time
4. Non contact measurement, with a service life of 10 years
5. Easy installation and maintenance, low usage cost
Typical applications:
1. Hydrogen sulfide detection in natural gas pipelines
2. Monitoring of hydrogen sulfide in incineration flue gas
3. Process control in chemical engineering
4. Pollution source emission monitoring
5. Monitoring before and after desulfurization
Explosion proof laser flue gas online analysis system pollution source emission monitoring

| performance parameters | |||||
| model | gas | Detection range | resolution | response time | drift |
| LAS-100Ex | NH3 | 0-100ppm | ≤1%FS | ≤10s | ≤±1%FS 7d |
| LAS-200Ex | HCL | 0-100ppm | ≤1%FS | ≤10s | ≤±1%FS 7d |
| LAS-300Ex | HF | 0-100ppm | ≤1%FS | ≤10s | ≤±1%FS 7d |
| LAS-600Ex | H2S | 0-100ppm | ≤1%FS | ≤10s | ≤±1%FS 7d |
| Functional Parameters | |||||
| preheat | 30min | digital output | RS232/485 | analog output | 4-20mA maximum load 900 Ω |
| power supply |
AC100-240V 47-63Hz/1.5kW |
alarm function | Concentration over limit alarm, relay output alarm, laser temperature abnormal alarm |
||
| environmental parameters | |||||
| Measure optical path length | 10-50m | Sample gas temperature | ≤800℃ | Sample gas pressure | Atmospheric pressure ± 5kPa |
| sampling flow | 2-3L/min | ambient temperature | -30-55℃ | environmental stress | 70kPa-120kPa |
| Explosion-proof rating | ExdⅡCT6 | Protection level | IP65 | ||
| Overall dimensions | 650mm×400mm×1800mm | weight | 130kg | ||