Welcome Customer !

Membership

Help

Nanjing Jinnuo Instrument Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Explosion proof orifice flowmeter

NegotiableUpdate on 12/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Explosion proof orifice flowmeter $r $n orifice flowmeter is a high range ratio differential pressure flow device composed of a standard orifice plate and a multi parameter differential pressure transmitter (or differential pressure transmitter, temperature transmitter, and pressure transmitter). It can measure gas, steam, liquid, and induced flow rates and is widely used in process control and measurement in petroleum, chemical, metallurgical, power, heating, water supply and other fields. Jindi orifice flowmeter is a high range ratio differential pressure flow device composed of a standard orifice plate and a multi parameter differential pressure transmitter (or differential pressure transmitter, temperature transmitter, and pressure transmitter), which can measure the flow of gas, steam, liquid, and natural gas.
Product Details

Explosion proof orifice flowmeterIt is a high range ratio differential pressure flow device composed of a standard orifice plate and a multi parameter differential pressure transmitter (or differential pressure transmitter, temperature transmitter, and pressure transmitter), which can measure the flow of gas, steam, liquid, and natural gas.

Product Application:

Widely used in process control and measurement in fields such as petroleum, chemical, metallurgy, electricity, heating, and water supply. Orifice flow meters are widely used in various fields of the national economy, such as coal, chemical, transportation, construction, textile, food, medicine, agriculture, environmental protection, and people's daily lives. They are an important tool for developing industrial and agricultural production, saving energy, improving product quality, enhancing economic efficiency, and management level. They occupy an important position in the national economy. In process automation instruments and devices, flow meters have two main functions: as detection instruments for process automation control systems and as total quantity meters for measuring material quantities.

Debugging method:

1. Connect the signal line and power line
2. Open the inlet and outlet valves, and ensure that the opening of the inlet and outlet valves is consistent
3. Open the stainless steel three valve group balance valve, slowly open the valves at the high and low pressure ends of the orifice plate, and close the stainless steel three valve group balance valve after the fluid passes through the flowmeter.

Scope of application of orifice flowmeter:
1. Nominal diameter: 50mm ≤ DN ≤ 1200mm (exceeding this range is considered a non-standard throttling device)
2. Nominal pressure: PN ≤ 16MPa
3. Aperture ratio: 0.20 ≤ β ≤ 0.75
4. Reynolds number range: 5000 ≤ ReD when 0.20 ≤ β ≤ 0.45
When 0.45 ≤ β ≤ 0.75, 10000 ≤ ReD
5. Accuracy: Level 1

Explosion proof typeorifice plate flowmeterInstallation requirements:
1. During installation, it should be ensured that the center of the orifice plate, flange center, pipeline center, and gasket are concentric, and the eccentricity should not exceed 0.002D/β.
2. The positive and negative pressure directions of the orifice plate, as well as the upstream and downstream pressure tapping flanges, should be consistent with the flow direction of the medium. The orientation of the pressure tapping holes can be determined according to the different media and the installation of the transmitter.
3. When connecting the throttling device to the pipeline, the non perpendicularity between the welding end face and the pipeline axis shall not exceed 1 °. After welding, the internal weld seam should be processed to make it smooth and free of welding bars and slag.
4. Before welding the pressure tapping flange to the pipeline, the pressure tapping hole on the pipeline should be drilled with the same diameter as the pressure tapping hole on the pressure tapping flange. During welding, the pressure tapping hole on the pressure tapping flange should be aligned with the pressure tapping hole on the pipeline.
5. Optional upstream and downstream straight pipe sections.
6. D-D/2 pressure tapping is supplied as a complete set, and flange connection can be directly installed.

Nanjing Jinnuo Instrument Co., Ltd. is a production-oriented economic entity mainly engaged in flow products. After years of effort, the company has been honored with titles such as "User Trusted Unit" and "Jiangsu Province Trademark Enterprise" based on the concepts of "creating value for customers" and "winning the market with integrity". Our company's flow products mainly include: standard orifice plate series, standard nozzle series, Venturi tube series, V-shaped cone flow sensor, wedge-shaped flow sensor, bent pipe flow sensor, Annubar flow sensor and other flow instruments. Welcome new and old customers from home and abroad to come for consultation, inspection, and purchase.