E-mail
zgybzj@163.com
-
Phone
13915191836
-
Address
No. 359 Shenhua Avenue, Jinhu County Economic Development Zone, Jiangsu Province
Jiangsu Jinnuo Instrument Co., Ltd
zgybzj@163.com
13915191836
No. 359 Shenhua Avenue, Jinhu County Economic Development Zone, Jiangsu Province
F. M flowmeter FM flowmeterManufacturer Price Phone (WeChat): 1 3 9-1 5 1 9-1 8 3 6
F. The M flowmeter utilizes the principle of low voltage and multi pulse difference, and adopts high-precision and ultra stable dual balanced signal differential transmission to measure the ultrasonic transmission time in the forward and reverse directions, and calculates the flow velocity based on the time difference. When an ultrasonic beam propagates in a liquid, the flow of the liquid will cause a slight change in propagation time, which is proportional to the flow velocity of the liquid. At zero flow rate, the time required for both sensors to emit and receive ultrasonic waves is the same
Features:
The design of the plug-in structure is to solve the problem of thick fouling inside the large-diameter pipe wall, which cannot be solved by general external binding methods when measuring pipelines on site. The plug-in structure should be used.
★ Obvious price advantage, the price is independent of the pipe diameter. When the pipe diameter is greater than 500mm, its cost is a fraction of that of an electromagnetic flowmeter.
★ Save on shipping and installation costs.
★ It can be installed without interruption, and the manufacturer provides specialized drilling equipment to guide installation.
The sensor is not affected by adhesives, oil stains, or emulsions when transmitting and receiving signals.
★ Low voltage excitation has a long service life for sensing components.
★ Can measure bidirectional flow, * small flow velocity ≤ 0.05mm/s
★ Measuring liquids can be conductive or non-conductive media
★ It can achieve wireless function and transmit the data measured on site to the control room through wireless network.
Technical parameters of ultrasonic flowmeter:
★ Flow rate range: 0. 04~32m/s
★ Pipe diameter: φ 100mm~φ 3000mm
★ Pressure range: ≤ 1.6Mpa
★ Instrument accuracy: 1% FS (can reach level 0.5 after calibration)
★ Power supply mode: DC 12V~36V.DC or~220VAC
★ Output mode: 4-20mADC (1.2K Ω) Pulse: (can be set arbitrarily): RS232/485 interface
★ Working temperature: ≤ 120 ℃
★ Protection level: IP65
★ Explosion proof grade: EXd Ⅱ BT4
★ Other functions: It can record the cumulative traffic and working status of the first 64 days, the first 64 months, and the first 5 years. It can also record the time and traffic of the first 64 power outages, and can achieve traffic and automatic or manual replenishment
F. M flowmeter FM flowmeterMeasurement medium:
Measurable conductive and non-conductive homogeneous fluid. Such as: ionized water, seawater, acidic and alkaline liquids, food oil, gasoline, kerosene, diesel, engine oil, alcohol, beer, and other homogeneous liquids that can propagate ultrasonic waves.