The NMHC flame ionization detector (FID) hydrocarbon analyzer can achieve continuous high-precision detection. Due to its modular design, it can be applied to various non methane total hydrocarbon emission detection fields through different configurations, such as fixed pollution source emission monitoring, environmental monitoring, automobile engine exhaust emission monitoring, catalytic and thermal oxidizer plants, exhaust gas treatment plants, indoor and ambient air detection.
After entering the hydrocarbon analyzer, the high-temperature sample gas is transmitted to the burner, where H2 is supplied. At the same time, filtered and purified combustion air is provided to the burner through an internal generator. Carbon and hydrogen molecules decompose at high temperatures in the flame zone of the burner, producing an ion current. The intensity of the ion current is proportional to the number of carbon atoms in the sample gas. By detecting the ion current, the concentration of total hydrocarbons in the sample gas can be accurately obtained. All parts in contact with the sample gas, such as ion detectors and pipelines, are heated at high temperatures. The detector is specially designed to obtain the current measurement output signal at any measurement range, regardless of the measured concentration. The burner is of the "nozzle" type. Special vacuum type burner design, with the sampling pump located downstream of the burner, avoids the impact of pump membrane contamination on the measured values. At the same time, higher burner operating temperatures can be achieved.
Easy to operate
The hydrocarbon analyzer adopts a modular design for easy maintenance and operation;
200℃
NMHC flame ionization detector temperature 200 ℃;
Automatic ignition
The NMHC flame ionization detector has automatic ignition function;
Auto Close
The hydrocarbon analyzer has an automatic shut-off function for hydrogen supply;
Fast response speed
The response time of the hydrocarbon analyzer is extremely fast, with a T90 of less than 1 second;
|
High temperature detector, with a detection module temperature of up to 300 ℃, used to detect gases containing high molecular weight semi volatile hydrocarbons |
|
RS232 data communication module and data acquisition software |
|
Range automatic switching control module |
|
Temperature and pressure control module |
|
Main sampling pipeline high flow heating sampling pump, used to improve system response time, sampling flow rate 10L/min or 30L/min |
|
Heating sampling pipeline with 2 µ m dust filter at the top, standard gas can be injected into the system from the top of the sampling line to achieve overall calibration and calibration of the system |
|
Maintenance free vacuum jet sampling pump |
|
High purity hydrogen generator |
|
Zero gas generator/high-purity nitrogen generator |
|
Cabinet system integration |