The FP-30 test strip photoelectric photometric formaldehyde detector is the only one that uses the national standard method and completes sampling and testing simultaneously on site.
FP-30 formaldehyde detector is a product of Riken Instrument Co., Ltd. in Japan, which has continuously developed advanced products in the fields of industrial disaster prevention and environmental monitoring, and has obtained ISO9001 quality system certification and ISO14001 environmental protection system certification. The winning instrument for Olympic venue testing.
Detection Principle
When gas is blown onto the detection TAB, the paper immersed in the coloring agent combined with the TAB will undergo a chemical reaction and change color. For example, after formaldehyde is attached to paper, the reagent contained in the paper will react with formaldehyde to form a compound, and the color will change from white to yellow. The degree of color change can reflect the amount of reflected light received. The rate of change in the intensity of reflected light can be used as a gas concentration response. By setting the detection line in advance, the concentration of the gas can be determined by the response value of the gas being detected.
Product Features:
1. Simply install the testing pills for easy detection
2. Comes with reliable self diagnostic function
3. Comes with automatic storage function for measurement data (99 sets) and can be downloaded to a PC
4. No preheating time required
5. Automatic backlit display
Technical Indicators:
|
gas detection |
Formaldehyde in the atmosphere |
|
Detection Principle |
Experimental paper photoelectric photometry method |
|
Testing Scope |
0~0.4 ppm(TAB No.008) 0~1.0 ppm(TAB No.009) |
|
Detection Time |
30 minutes (1800 seconds), 15 minutes (900 seconds) |
|
resolution |
0.005 ppm and 0.01 ppm |
|
Detection method |
Detecting TAB method (adding calculated values within time) |
|
Concentration representation method |
LCD (Liquid Crystal Display) |
|
sampling method |
pump-suction type |
|
working environment |
-10~40℃; Below 90% RH (no condensation) |
|
memory function |
Detection points: 99 points (automatically stored upon completion of measurement), with automatic storage function for measurement data (99 sets) and downloadable to PC |
|
Self diagnostic function |
Self check for poor battery voltage, low pump, abnormal system, abnormal temperature, etc. in the light source and light receiving unit |
|
power supply |
4 alkaline dry batteries |
|
Continuous usage time |
About 12 hours (alkaline dry battery without lighting or alarm at 20 ℃) |
|
Overall dimensions |
Approximately 85 (W) × 190 (H) × 40 (D) mm (excluding protruding parts) |
|
weight |
About 500 grams (host) |