Product details and technical parameters: The device supports 8 RS485/RS232 serial port inputs, 3 network port designs, supports 10M/100M/1000M Ethernet interfaces, memory ≥ 500GB; 8GB memory; 2 USB interfaces; 1 VGA interface; 1 HDMI interface; Dual power supply design
Product Details
Product Details
Technical Specifications:
The device supports 8 RS485/RS232 serial port inputs, 3 network port designs, supports 10M/100M/1000M Ethernet interfaces, memory ≥ 500GB; 8GB memory; 2 USB interfaces; 1 VGA interface; 1 HDMI interface; Dual power supply design.
Support the architecture of distributed collection and centralized monitoring to achieve comprehensive monitoring, data collection, processing, analysis, storage, and display of various subsystem infrastructure. The system has a clear and concise Chinese interface, unified alarm, permission, log, and backup management functions, as well as an alarm notification and report publishing platform, and supports complex event analysis.
The system has multiple alarm output modes, supports interface pop ups, on-site sound and light, etc., and also has functions of data processing, data filtering, data extraction (supporting the extraction of various key data), and data storage;
Log management requirements: System logs should provide user operation logs and event logs, supporting queries based on conditions (including but not limited to space, equipment, type, time, personnel, etc.). System logs cannot be modified or deleted by anyone, and can be saved for up to 6 months or even longer. After storage expires, the original data will be automatically overwritten, and the system will prompt backup. Authorized computer room administrators can back up according to their needs to ensure the authenticity and traceability of data;
The system supports RS232, RS485, I/O, MQ, etc. to ensure the authenticity and traceability of data;
The system supports accessing the monitoring system through configuring SNMP protocol interfaces
The device system adopts B/S architecture, supports WINDOWS/Linux operating system, can be accessed, browsed and operated directly through WEB browser, and supports browsers such as Google and IE;
Implementation function:
Distribution monitoring: meet the real-time monitoring of phase voltage, line voltage, phase current, frequency, power factor, active power, reactive power, branch parameters and status (including but not limited to) of the power supply incoming line of the distribution cabinet;
UPS monitoring: It meets the real-time monitoring of the operating status (including but not limited to) of various components such as rectifiers, inverters, batteries, bypasses, loads, etc. inside the UPS. Once a component fails or parameters exceed the limit, the system will automatically alarm;
Battery monitoring: meet the real-time monitoring of battery cell voltage, cell internal resistance, cell temperature, cell status, total voltage, charging and discharging current and other states and parameters;
Precision air conditioning monitoring: meets the requirements for air conditioning operation status and parameters, including but not limited to return air temperature, return air humidity, compressor operation status, dehumidifier operation status, humidifier operation status, filter screen status, heater operation status, refrigerator operation status, air conditioning water leakage alarm, high temperature and humidity alarm, low temperature and humidity alarm, etc;
The system is capable of providing software interfaces for monitoring distribution cabinets, UPS, battery, precision air conditioning, and environmental monitoring simultaneously.machine