Factory boundary and ambient air VOCs fully online monitoring system

NegotiableUpdate on 11/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Factory boundary VOCs online monitoring system/main configuration: The equipment for the VOCs online monitoring system in the park includes: a fully online dual cold trap atmospheric VOCs pre concentration host; Gas chromatography with FID detector, FPD detector, or ECD detector paired with chromatographic column; Hydrogen air integrated machine; Software and accessory packages; Data transmission interface

Product Details

Factory VOCs online monitoring system/Main Configuration

The main configuration of the VOCs online monitoring system equipment in the industrial park includes: a fully online dual cold trap atmospheric VOCs pre concentration host; Gas chromatography with FID detector, FPD detector, or ECD detector paired with chromatographic column; Hydrogen air integrated machine; Software and accessory packages; Data transmission interface.

Factory VOCs online monitoring system/feature

  • The collection time can be controlled

    The collection time of VOCs online monitoring equipment in the factory can be controlled within 3-60 minutes, and the time is easy to adjust;

  • No monitoring time blind spot

    The VOCs online monitoring system equipment in the industrial park adopts dual cold trap monitoring, with no blind spots in monitoring time;

  • Monitoring of highly active substances

    The online monitoring system for VOCs in the factory adopts inert pipelines and valve bodies, which are suitable for monitoring highly active substances;

  • FID detector

    If the online monitoring system equipment is connected with a FID detector, it is suitable for monitoring benzene derivatives and PAMS;

  • FPD detector

    Connecting VOCs online monitoring equipment with FPD detectors is suitable for detecting sulfide compounds;

  • ECD detector

    If the VOCs monitoring system equipment is connected with an ECD detector, it is suitable for detecting chlorinated hydrocarbon compounds;

  • Precision electronic pneumatic control

    The factory monitoring system adopts precision electronic gas path control, with stable retention time and easy qualitative analysis;

  • Accurate quantitative results

    The VOCs online monitoring system equipment in the industrial park has accurate quantitative results and high precision;

  • low power consumption

    The VOCs online monitoring system equipment in the factory can be powered by mains electricity, with low power consumption and easy maintenance;

  • Large sampling volume

    The VOCs online monitoring system equipment has a large sampling volume, making it particularly suitable for large-scale concentration of low concentration samples.

Factory VOCs online monitoring system/parameter

performance metrics
Sampling volume of 0.1-6L, adjustable sampling flow rate and time
Detection limit for hydrocarbons: 0.1 ppb-10 ppb (may vary depending on the compound)
Sulfur compound detection limit: better than 0.2 ppb (may vary depending on the compound)
Linear correlation greater than 99%
Repeatability less than 10%

Factory VOCs online monitoring system/application

PAMS monitoring of ozone precursors in the factory and ambient air; Monitoring of C2-C12 alkane compounds, such as benzene derivatives, in the factory and ambient air; Monitoring of odor, foul odor, sulfides, aldehydes, ketones, and ester compounds; Monitoring of toxic and harmful halogenated hydrocarbons; Online monitoring of VOCs emissions at the boundary of enterprise factories and industrial parks.