E-mail
zw9596@163.com
-
Phone
13062028296
-
Address
39 Parallel North Road, Tengzhou City, Shandong Province (Taoyuan Huayuan Office Building)
Shandong Luchuang Analytical Instrument Co., Ltd
zw9596@163.com
13062028296
39 Parallel North Road, Tengzhou City, Shandong Province (Taoyuan Huayuan Office Building)
Zirconia gas chromatograph is a chromatographic analysis instrument that uses zirconia solid electrolyte primary cells as detectors, specifically designed to analyze the content of trace amounts of hydrogen, oxygen, methane, and carbon monoxide in high-purity inert gases. It has the characteristics of high sensitivity, high selectivity, and simultaneous analysis of multiple components in one injection. It can be equipped with a hydrogen flame ionization detector according to user needs, and can also detect carbon dioxide and total hydrocarbons. It is a very practical instrument for gas production and use units. Main applications: Used for the detection of food grade nitrogen, laboratory testing of high-purity inert gases, and gas quality control in gas production of air separation units. The high sensitivity of the instrument can effectively solve the separation of hydrogen in neon and oxygen in argon.
Performance characteristics
1. Zirconia detector uses highly sensitive zirconia tubes;
2. Adopting non permeable and non diffusive valve components for injection, manual or automatic injection can be selected as needed;
3. The main control circuit adopts advanced microprocessors, large-scale integrated circuits, and advanced surface mount packaging; The integrated main control circuit board design improves the anti-interference and reliability of the instrument;
4. Adopting a 7-inch touch screen LCD display, the use of shortcut keys is more convenient for operation;
5. The whole machine has good air tightness, low baseline noise, high analysis sensitivity, and good reproducibility;
6. The host comes with a four-way valve control system, which facilitates online sampling and automatic analysis of various blowback switches;
7. The flame ionization detector adopts a collection electrode with a cylindrical structure, a quartz nozzle, and electronic automatic ignition.
GC-9870Characteristics of Gas Chromatography Instruments:
1.Switching display technology between Chinese and English,5.7Inch LCD large screen(320*240). up to20A display interface with abundant information and storage capability10Set chromatographic analysis data and can be accessed at any time.
2.Industrial design appearance, novel and elegant, beautiful and practical, reasonable structure, and comfortable operation.
3.Equipped with gas cutoff protection function, it maximizes the protection of chromatographic columns, thermal conductivity cells, electron capture detectors, etc.
4.The eighth order linear program heating function and intelligent dual rear door design truly achieve near room temperature control and precise temperature control
Up to degree±0.1℃ meets the requirements of wide range analysis
5.Complete overheating protection and platinum resistance open circuit and short circuit alarm functions ensure that the instrument is not damaged.
6.Powerful self diagnostic function and Chinese fault prompts enable users to easily know the cause and location of the problem.
7.Adopting advanced technologyFLASHMemory system ensures that data is permanently protected without relying on batteries.
8. Microcomputer controlFIDThe detector has achieved automatic ignition function.
9.The high-precision stable voltage and current mode ensures precise and stable airflow. Multi channel pneumatic control system, expandable to21The road.
10.High performance capillary dedicated vaporization chamber achieves true diversion/Non split injection system.
11.Can be installed simultaneously1-4A detector. Can be doubleFIDOr doubleTCDOr doubleECDOr doubleNPDfunction.TCDEquipped with dual columns for gas replenishment, it can be used for single column, dual column, or capillary column.
12. Can install and run simultaneously1-3Install capillary column and operate simultaneously3A detector.1The instrument is equivalent to3Platform (shared by pillar room). Or doubleFIDDouble hair. twoTCDDouble hair. twoTCDWorking simultaneously without affecting each other, the carrier gases can be independent of each other. Avoiding the tedious process of replacing chromatography columns and detectors.
13.It can realize the series and parallel use of detectors, and perform intelligent automatic conversion through event control.
14.The instrument can be installed with a conversion furnace, thermal desorption apparatus, automatic sampler, automatic headspace sampler, cracking apparatus, and more
Planting injection method. Automatic sampling can be scheduled to achieve automatic online analysis.
15The instrument is particularly suitable for various enterprises, technical supervision bureaus, environmental monitoring, health and epidemic prevention, universities, scientific research and other departments.
Main features and technical parameters

1.Temperature control range: room temperature+5℃--400℃ increment0.1℃ accuracy±0.1℃
TPD8steps heating rate0.1-50℃/min
2.FID: Mt≤2*10-12g/s (HEXADECANE)
Rn≤2*10-14A(0.02mv)
Rd≤1.5*10-13A/30min(0.15mv/0.5h)
Linear range: ≥107
3.TCD: S≧10000mv.ml/mg(N-hexadecane)
Rn≤20uv
Rd≤150uv/30min
Linear range: ≥104
After the dual column is used to supplement air, it can be used as a capillary tube
4.ECD: Mt≤3×10-14g/ml(γ-666)
Rn≤20uv
Rd≤150uv/30min
Linear range: ≥104
radioactive sourceNi63
5.FPD: Mp≤1*10-12g/s (1605)
Ms≤1*10-12g/s (Saiphenol)
Rn≤40uv
Rd≤150uv/30min
Linear range: ≥103
6.other:
External dimensions:520×480×500mm(Long)×wide×High)
Instrument weight:50Kg
Maximum power:2000W
Voltage:220±10% 50Hz