GL SPECTIS 4.0 UV Visible Near Infrared Spectrometer

NegotiableUpdate on 12/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The available spectral working range of GL Spectis 4.0 starts from 200nm up to 1050nm. The dedicated thermal adjustment function can stably read at different application temperatures up to 35C. Due to proper calibration, the absolute UV spectral values are not affected by stray light.
Product Details

The available spectral working range of GL Spectis 4.0 starts from 200nm, straight * * 1050nm. The dedicated thermal adjustment function can stably read at different application temperatures up to 35 ° C. Due to proper calibration, the UV spectral values are not affected by stray light. The wavelength and linearity correction are verified using an optical bench. **The reading is completely consistent with the blackbody radiation standard, and a deuterium lamp is used to check if the ultraviolet range is short. The UV and IR measurements of GL Specis 4.0 can fill the gaps in various new LED applications.

The GL Spectis 4.0 optical luxmeter features Hamamatsu's large laboratory grade back thin CCD sensor, which provides excellent stability over longer exposure times. Use reference standards to calibrate equipment, which can be traced back to national laboratories and confirmed through globally recognized factory calibration. The electronic dark current level is automatically monitored through intelligent compensation to compensate for any drift caused by temperature fluctuations.

The GL Spectis 4.0 USB spectrometer features a new photonics solution that enables precise optical quality control in various applications. For demanding measurement applications in laboratories or production, this fully calibrated spectrometer is the ideal solution. Simply connect it to a PC and it can be used in laboratories, production sites, or other industrial settings where measuring light or any other radiation is necessary.

With the universal design of Spectis 4.0, you can easily build specialized measurement systems. By adding any of our optical probes, this instrument can measure irradiance using standard diffusers or fiber optic probes. When connected to the integrating sphere, the total luminous flux and radiated power can be measured. When used in conjunction with a brightness/emissivity telescopic probe, specialized assessments of the hazards and quality of light radiation can be obtained.

This spectral radiometer is highly suitable for LED measurement and can be paired with any of our integrating sphere and angle measuring systems for pre measurement according to CIE 127:2007 and CIE 025/E: 2015. The high precision and resolution make it an ideal measuring instrument for confirming (IES) LM-79-08 and other international standards.

The GL Spectis 4.0 spectrometer has been optimized for rigorous testing and measurement, consistently providing accuracy comparable to many expensive and complex measuring instruments. The stray light suppression system and automatic temperature compensation help achieve accurate results.

GL SPECTIS 4.0紫外可见近红外光谱仪(图1)

system function

  • Expand spectral range

The Spectis 4.0 spectral radiometer has a wide wavelength range of 200 * * * 1050nm and can be measured according to many standards, including photobiological safety (EN 62471) or SSL product measurement (IESNA LM-79-08).

  • Photometric and radiometric calibration

Before delivery, * * spectral calibration has been integrated into each spectrometer. According to the installed measurement accessories, it can accurately measure different * * values (such as lux, candela, or lumens) as well as radiation values.

  • Dark current compensation

Although it is not a cooled detector, the GL Spectis 4.0 spectrometer can still provide very accurate measurements under different conditions. The temperature sensor installed on the electronic board monitors temperature changes and automatically compensates for any changes in dark current levels, providing excellent measurement stability.

  • Provide multiple integrating spheres and probes

With the universal concept and design of Spectis 5.0 Touch, you can easily expand your measurement system by adding any of our integrating spheres or other accessories.

GL SPECTIS 4.0紫外可见近红外光谱仪(图2)

System indicators

  • Lux/Lux - irradiance

  • Lumen/Lumen - Luminous flux

  • CRI - Color rendering index (compliant with CIE standards)

  • CCT - Color Temperature (in accordance with the standard CIE)

  • Color - Chromatic Coordinates (CIE 1931 and CIE 1964)

  • Fidelity and Color Gamut - Method for Evaluating Light Source Color Restoration According to TM-30 IES Standard

  • PAR/PPFD - photosynthetically active radiation measurement (horticulture)

  • EML - Equivalent Black Luminous Lux/Equivalent Black Luminous Illumination

  • MWatt - Radiant Energy

System specification parameters

application

application

Application of high-precision laboratory and industrial measurement

LED measurement

Illuminance (lux)*

5 lx – 150000 lx(GL Spectis 4.0 UV-VIS-NIR)

Brightness [cd/m ²]

Provided together with the optional GL Opti probe

Luminous flux [lm]

Provided together with the optional GL Opti probe

Luminous intensity [cd]

Calculate with SPECTRSOFT

Illumination level

B-class - DIN 5032-7;

On demand Class A

AA level - JIS C 1609-1:2006

Tolerance - cosine response (f2 ')

<3%(1.9%)

Spectral Range**

200 – 1050 nm(GL Spectis 4.0 UV-VIS-NIR)

200 – 430 nm(GL Spectis 4.0 UV)

Luminosity/radiance

sensor

Back illuminated CCD

Pixels

2048

Physical resolution/data point interval

〜0.5 nm

Wavelength reproducibility

±0.5nm

integration time

10ms~10s

A/D conversion

16bits

Signal to Noise Ratio

1000:1(GL Spectis 4.0 UV-VIS-NIR)

500:1(GL Spectis 4.0 UV)

stray

2*10E-4

Optical resolution/FWHM

2.5 nm(GL Spectis 4.0 UV-VIS-NIR)

0.3nm(GL Spectis 4.0 UV)

Radiation accuracy * */* */****

6% (within the range of 200-220 nm)

5% (within the range of 220-500 nm)

4% (within the range of 500-1050 nm)

Flicker compensation

Temperature sensor and dark current compensation

Measurement uncertainty of color coordinates (x.y)**

±0.0015

Automatic attachment detection

N / A

operation temperature

5-35°C

Dimensions [H x W x D]

70 mm x 170 mm x 200 mm

weight

1660 g

tripod adapter

Interface and Memory

USB

USB 2.0

trigger

4-pin pluggable terminal block

data format

XML

Fiber Connector

SMA with fixed position system

Display and operation

software

GL SPECTROSOFT Basic / Pro / Lab /

Development kit

DLL driver program

ordering information

toolbox

usb cable

*The dynamic range is related to the spectrum and should be calculated separately for any light source. The estimated dynamic range of a typical 4000 K white LED.
The estimated range of the optical system has been set to the default specifications. It can usually be modified. If you are looking for specific parameters, please consult technical support.

**The spectral range of the sensor. Due to limitations in the use of optical accessories, the actual spectral range of the system may be reduced.

***Immediately after calibration, measurement uncertainty appears. The expanded uncertainty corresponds to a coverage probability of 95%, with a coverage factor of k=2.
This parameter is effective under laboratory conditions of 25 ° C and relative humidity of 45%

****Only applicable within the spectral range of the given model.

Attention: Instrument, firmware, and software specifications are subject to change without prior notice. All information contained in the GL OPTIC data sheet, as well as any form of product information, has been carefully prepared and includes truthful information. Please note that differences may occur due to text and/or other errors or changes in available technology. It is recommended to contact us before using the product to obtain Z's new product specifications.

Applicable to:

  • Lamp manufacturers, installers, and lighting auditors

  • Lighting Design Engineering Company

  • Lighting testing agency

  • Environment or personnel related to lighting inspection and testing

  • Suitable for various optical measurement applications from laboratory to on-site testing


Similar Product Recommend