Gas chromatograph | Technical parameters of ester alcohol analyzer in Baijiu $r $n ●& #160; Pressure protection method: The carrier gas has pressure protection function. When the gas pressure drops to 0.1mpa, the instrument automatically cuts off the power supply to effectively protect the safety of the chromatographic column. FID has automatic ignition function and does not require manual ignition. $r $n ●& #160; Display mode: 7-inch touch screen display $r $n ●& #160; Temperature control area: 10 channels temperature control $r $n ●& #160; Temperature control accuracy:& #177; 0.1℃-& #177; 0.2 ℃ $r $n ●& #160; Temperature control range: room temperature& #177; 8 ℃ -450 ℃, with increments of 1 ℃
Gas chromatograph | ester alcohol analyzer in BaijiuThe main performance characteristics are:
Can replace traditional high-pressure air cylinders and make laboratories instrument
The purifier uses PC polycarbonate tubing Voltage resistance Resistant to reagents Impact resistant Not easily broken High intensity
Easy to operate, just turn on the power switch to produce gas Smooth operation
Overpressure and overcurrent Overheating level three automatic protection
Three stage purification of gas system and two-stage voltage stabilization High voltage stabilization accuracy
Automatic drainage Effectively extend the service life of the instrument
Temperature control range: room temperature ± 8 ℃ -450 ℃, with increments of 1 ℃
● Program heating: 16 stage program heating, heating rate 0.1-40 ℃/min, with increments of 0.1 ℃,
Initial and termination time range: 0-6000min, with increments of 1min.
● Extreme temperature: 450 ℃
External events: 8-channel external events can be installed with solenoid valves, etc
Power supply: 220V 50HZ 2000W
Pressure protection method: The carrier gas has a pressure protection function, and the instrument automatically switches when the gas pressure drops to 0.1mpa
Cutting off the power effectively protects the safety of chromatographic column use. FID has automatic ignition function and does not require manual ignition.
● Display mode: 7-inch touch screen display
● Temperature control area: 10 temperature control channels
Temperature control accuracy: ± 0.1 ℃ - ± 0.2 ℃
Temperature control range: room temperature ± 8 ℃ -450 ℃, with increments of 1 ℃
● Program heating: 16 stage program heating, heating rate 0.1-40 ℃/min, with increments of 0.1 ℃,
Initial and termination time range: 0-6000min, with increments of 1min.
● Extreme temperature: 450 ℃
External events: 8-channel external events can be installed with solenoid valves, etc
Power supply: 220V 50HZ 2000W
Gas chromatograph | ester alcohol analyzer in BaijiuTechnical parameters
Pressure protection method: The carrier gas has a pressure protection function, and the instrument automatically switches when the gas pressure drops to 0.1mpa
Cutting off the power effectively protects the safety of chromatographic column use. FID has automatic ignition function and does not require manual ignition.
● Display mode: 7-inch touch screen display
● Temperature control area: 10 temperature control channels
Temperature control accuracy: ± 0.1 ℃ - ± 0.2 ℃
Temperature control range: room temperature ± 8 ℃ -450 ℃, with increments of 1 ℃
● Program heating: 16 stage program heating, heating rate 0.1-40 ℃/min, with increments of 0.1 ℃,
Initial and termination time range: 0-6000min, with increments of 1min.
● Extreme temperature: 450 ℃
External events: 8-channel external events can be installed with solenoid valves, etc
Power supply: 220V 50HZ 2000W