Gas steam vortex flowmeter

NegotiableUpdate on 08/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

High quality gas steam vortex flowmeter manufacturers provide you with comprehensive product information, which belongs to high-quality vortex flowmeter products. We have rich experience in flow measurement and metering scheme design. For more information about gas steam vortex flowmeter manufacturers, quotation and model selection services, please feel free to contact us at any time.

Product Details

Gas steam vortex flowmeterThe manufacturer of the production quotation for this flowmeter product model belongs tovortex flow meterFor more direct price quotations of gas, steam, vortex street, and flow control instruments, please feel free to inquire by phone. Below is the product information and details of gas steam vortex street flowmeter.

Gas steam vortex flowmeter is a type of gas flowmeter. In fact, there is another popular flowmeter model in the selection of steam flowmeter, which is the rotor type steam flowmeter. For more information, please click to go. This article only introduces the use of gas steam vortex flowmeter. Vortex flow meters are also suitable for measuring steam flow meters and are widely used for measuring instantaneous or cumulative flow rates of various gases. They can integrate temperature and pressure sensors to achieve the effect of a temperature pressure integrated gas steam vortex flow meter.

气体蒸汽涡街流量计

Steam vortex flowmeter is mainly used for flow measurement of steam medium fluid in industrial pipelines. The characteristics of steam vortex flowmeter are small pressure loss, large measurement range, and high accuracy. It is almost unaffected by fluid density, pressure, temperature, viscosity, and other parameters.

Introduction to Gas Steam Vortex Flow Meter

Steam vortex flowmeter is mainly used for flow measurement of steam medium fluid in industrial pipelines. The characteristics of steam vortex flowmeter are small pressure loss, large range, high accuracy, and it can be used under measurement conditions. The volumetric flow rate is almost unaffected by fluid density, pressure, temperature, viscosity, and other parameters. Due to the absence of active mechanical parts, it has high reliability and low maintenance costs. The instrument parameters can be stable for a long time. The steam vortex flowmeter adopts a piezoelectric stress sensor, which has high reliability and can operate within a working temperature range of -20 ℃ to+250 ℃. It has analog standard signal and digital pulse signal output. It is easy to use with digital systems such as computers. It is a relatively advanced and ideal flowmeter.

Steam flow meters are widely used in various industries for measuring steam, gas, and liquid flow rates.

If a triangular cylindrical vortex generator is installed in the steam fluid, regular vortices are alternately generated on both sides of the vortex generator. This type of vortex is called a Karman vortex. The vortex array is asymmetric downstream of the vortex generator. Align the ground. The patented technology of steam flowmeter solves the direct contact between the probe body of similar products and the measured medium. The temperature of the measuring medium is not high, making maintenance inconvenient. The steam flow sensor also has all the patented technologies, processes, and characteristics of a wide range (K) sensor. It is particularly suitable for high-temperature fluid media and room temperature fluid conditions, under which it is impossible to stop working or production and cut off maintenance. Greatly expanding the application range of steam flow meters.

The vortex flowmeter strictly follows the national industry standards (JB/T9279-1999) and metrological verification regulations (JJG198-94), providing a method to meet the requirements of industrial metrology, energy management, and engineering design in China. Professional latest standard eddy current steam flowmeter.

Technical parameter accuracy of gas steam vortex flowmeter

Liquid level 1.0, gas level 1.5 (within the standard flow range); Repeatability: 0.2%, 0.3%; Nominal diameter: DN50mm to DN500mm; Flow range: A) Extended flow range: Liquid 20:1, Gas 15:1; b) Standard flow range: Liquid 10:1, Gas 8:1; Nominal pressure: 2.5MPa; Temperature of the tested medium: -200 to+400 ℃; Pressure loss: drag coefficient Cd ≤ 2.4; Power supply: 12-24V DC;

Output signal: Voltage pulse: Low level ≤ 1V, High level ≥ 6V;

Standard power supply: 4-20mA DC;

10. Explosion proof mark: ia Ⅱ T6.

Characteristics of Gas Steam Vortex Flow Meter

  1. Wide temperature range of the tested medium;
  2. The steam flow sensor can remain online under normal temperature fluid conditions.
  3. Simple and sturdy structure, no moving or vulnerable parts, long service life;
  4. The vortex steam flowmeter has high measurement accuracy and low resistance loss;
  5. Easy installation and minimal maintenance;
  6. Steam flow meters can remotely transmit flow signals, thereby achieving centralized management.

The steam vortex flowmeter is a new type of flowmeter based on the Karman vortex principle for measuring fluid flow in closed pipelines. Due to its excellent medium adaptability, it can directly measure the volumetric flow rates of steam, air, gas, water, and liquid without temperature and pressure compensation. Equipped with temperature and pressure sensors, it can measure volumetric and mass flow rates under standard throttling conditions. The ideal alternative product for flow meters.

To improve the high temperature resistance and vibration resistance of steam vortex flowmeter, an improved vortex sensor has been developed. Due to its unique structure and material selection, this sensor can be used at high temperatures (350 ℃) and strong vibrations. (≤ 1g) Used for harsh working conditions.

In practical applications, the maximum flow rate is usually much lower than the upper limit of the instrument. As the load changes, the minimum flow rate is usually below the lower limit of the instrument. The best way to solve this problem is to reduce the diameter of the measuring point to increase the flow rate of the measuring point, and choose a smaller diameter instrument for convenient measurement. However, this restoration method must be carried out in the restoration tube. There is a straight pipe section between the instrument and the instrument used for calibration, with a length of 15D or longer, which brings inconvenience to processing and installation. The variable diameter rectifier with a longitudinal cross-section of a circular arc has multiple functions such as rectification, increasing flow rate, and changing flow distribution. Its structural dimensions are very small, only one-third of the inner diameter of the processing tube, and it is integrated with the vortex flowmeter. Adding straight pipe sections can also reduce the requirements for process pipe straight pipe sections, and installation is very convenient.

For convenience of use, the battery powered on-site display type steam vortex flowmeter adopts low-power high-tech. It can run continuously for more than a year using lithium battery power supply, thus saving the purchase and installation costs of cables and display instruments. It can display instantaneous traffic, cumulative traffic, etc. on the spot. The temperature compensated integrated vortex flowmeter also has a temperature sensor, which can directly measure the temperature of saturated steam and calculate the pressure, thereby displaying the mass flow rate of saturated steam. The temperature and pressure compensation integrated model is equipped with temperature and pressure sensors, which can be used for gas flow measurement to directly measure the temperature and pressure of the gas medium, thereby displaying the standard volumetric flow rate of the gas.

Steam vortex flowmeter is mainly used to measure the flow rate of steam medium fluid in industrial pipelines. The characteristics of steam vortex flowmeter are small pressure loss, large range, high accuracy, and almost no liquid when measuring volumetric flow rate under working conditions. The influence of parameters such as density, pressure, temperature, and viscosity. The medium used for measurement: gas, liquid, steam, it is a relatively advanced and ideal flowmeter. What issues should be noted when using a steam vortex flowmeter?

Precautions for the application of gas steam vortex flowmeter

Do not violently collide with the vortex flowmeter during transportation, and do not let rainwater wet it. Use our company's packaging as much as possible to transport the steam flowmeter directly to the installation site. Please confirm if there are any bumps or scratches during transportation when purchasing a steam flowmeter. Based on the product brand label, please confirm if it matches the model you are purchasing? When storing, please try using the company's original packaging for storage.

The venue should meet the following conditions:

① Places without rainwater

② Places with minimal vibration or collision

③ Temperature: -40 ℃~+55 ℃

④ Humidity: In the 5% to 90% eddy current flow meter used for storage, residual liquids and attachments inside should be thoroughly cleaned, and the power interface should be sealed to prevent moisture. It must be used under the conditions specified by the flowmeter. It is not feasible to use beyond this specification. If the flowmeter is damaged due to this reason, the maintenance cost will be borne by you.

atGas steam vortex flowmeterIf there is a problem, please contact us or maintenance personnel as much as possible, and do not blindly repair it yourself.

The above is the complete content of gas flowmeter, steam flowmeter, and vortex flowmeter products. Welcome to inquire about the selection and quotation of gas flowmeter, steam flowmeter, and vortex flowmeter.

This article address: Please do not delete when reposting! [Gas Steam Vortex Flow Meter]