H07RN-F cable manufacturer
H07RN-F-1 * 185 Wind Energy Cable H07RN-F Industrial Cable
H07RN-F cable usage:
Suitable for heavy equipment such as engines, large tools, motors, agricultural machinery, wind power generation, or construction equipment. Capable of withstanding significant stress. Used for dry or humid indoor environments, as well as outdoor or humid industrial environments, or as anti twist cables for fans. This cable can also be installed on plaster, temporary buildings, and residential campsites. It is also suitable for direct installation in machines, such as elevators and cranes, wind turbine towers, etc. They can be used for protection and fixed installation in pipelines and equipment, as well as for connecting cables such as motors.
H07RN-F cable technical parameters:
Rated voltage: 600/1000V
Insulation resistance:>1GWohm x cm
Test voltage: 2500V
Working temperature: -45 ° C to+90 ° C
Bending radius: 5 times the outer diameter of the cable
H07RN-F cable structure:
Compliant with CE0295/IEC228 Class 6, multi strand precision twisted flexible oxygen free fine copper wire conductor
EI4 type rubber composite core wire insulation, compliant with DIN CE0282 (color can be customized according to customer requirements)
EM2 rubber compound outer sheath (color can be customized according to customer requirements)
Characteristics of H07RN-F cable:
Flame retardant, UV resistant, ozone resistant
Small outer diameter, saving space required for cable installation
No harmful substances, in compliance with CE0295 standard
This product complies with the provisions of EEC Regulation 73/23 (Low Voltage Regulation) CE
Compliant with CE/TUV/VDE and other standards
H07RN-F single core type cable
| Number of cores/cross-sectional area MM2 | Number of shares/diameter per share | Sheath thickness MM | Maximum outer diameter MM | Nominal weight KG/KM |
| 1x1.5 | 30x0.25 | 0.8 | 6.0 | 49 |
| 1x 2.5 | 50x0.25 | 0.9 | 6.6 | 63 |
| 1x4 | 56x0.30 | 1.0 | 7.6 | 92 |
| 1x6 | 84x0.30 | 1.0 | 8.3 | 115 |
| 1x10 | 80x0.40 | 1.2 | 10.7 | 189 |
| 1x16 | 126x0.40 | 1.2 | 12.0 | 260 |
| 1x25 | 196x0.40 | 1.4 | 14.1 | 369 |
| 1x35 | 276x0.40 | 1.4 | 15.8 | 500 |
| 1x50 | 396x0.40 | 1.6 | 18.3 | 689 |
| 1x70 | 360x0.50 | 1.6 | 20.7 | 918 |
| 1x95 | 475x0.50 | 1.8 | 23.4 | 1202 |
| 1x120 | 608x0.50 | 1.8 | 25.6 | 1489 |
| 1x150 | 756x0.50 | 2.0 | 28.3 | 1824 |
| 1x185 | 925x0.50 | 2.2 | 31.0 | 2202 |
| 1x240 | 1221x0.50 | 2.4 | 34.5 | 2847 |
| 1x300 | 1525x0.50 | 2.6 | 37.7 | 3495 |
| 1x400 | 2013x0.50 | 2.8 | 37.7 | 3495 |
| 1x500 | 1769x0.60 | 3.0 | 37.7 | 3495 |
| 1x630 | 2257x0.60 | 3.0 | 37.7 | 3495 |
H07RN-F 2-core cable 450/750V
| Number of cores/cross-sectional area MM2 | Number of shares/diameter per share | Sheath thickness MM | Maximum outer diameter MM | Nominal weight KG/KM |
| 2 X 1.0 | 32/0.20 | 0.8 | 8.4 | 98 |
| 2 X 1.5 | 30/0.50 | 0.8 | 9.4 | 116 |
| 2 X 2.5 | 50/0.25 | 0.9 | 11 | 164 |
| 2 X 4.0 | 56/0.30 | 1.0 | 12.8 | 232 |
| 2 X 6.0 | 84/0.30 | 1.0 | 14.2 | 297 |
| 2 X 10.0 | 80/0.40 | 1.2 | 20.4 | 573 |
| 2 X 16.0 | 126/0.40 | 1.2 | 23 | 774 |
| 2 X 25.0 | 196/0.40 | 1.4 | 27.4 | 1110 |
| 2 X 35.0 | 276/0.40 | 1.4 | 30.8 | 1474 |
H07RN-F 3-core cable 450/750V
| Number of cores/cross-sectional area MM2 | Number of shares/diameter per share | Sheath thickness MM | Maximum outer diameter MM | Nominal weight KG/KM |
| 3 X 1.0 | 32/0.20 | 0.8 | 9.0 | 108 |
| 3 X 1.5 | 30/0.50 | 0.8 | 10.3 | 141 |
| 3 X 2.5 | 50/0.25 | 0.9 | 11.8 | 200 |
| 3 X 4.0 | 56/0.30 | 1.0 | 13.7 | 285 |
| 3 X 6.0 | 84/0.30 | 1.0 | 15.2 | 371 |
| 3 X 10.0 | 80/0.40 | 1.2 | 21.9 | 712 |
| 3 X 16.0 | 126/0.40 | 1.2 | 24.7 | 971 |
| 3 X 25.0 | 196/0.40 | 1.4 | 29.4 | 1394 |
H07RN-F 4-core cable 450/750V
| Number of cores/cross-sectional area MM2 | Number of shares/diameter per share | Sheath thickness MM | Maximum outer diameter MM | Nominal weight KG/KM |
| 4 X 1.0 | 32/0.20 | 0.8 | 10.0 | 134 |
| 4 X 1.5 | 30/0.25 | 0.8 | 11.2 | 174 |
| 4 X 2.5 | 50/0.25 | 0.9 | 12.6 | 249 |
| 4 X 4.0 | 56/0.30 | 1.0 | 15.1 | 361 |
| 4 X 6.0 | 84/0.30 | 1.0 | 16.9 | 480 |
| 4 X 10.0 | 80/0.40 | 1.2 | 24 | 890 |
| 4 X 16.0 | 126/0.40 | 1.2 | 27 | 1225 |
| 4 X 25.0 | 196/0.40 | 1.4 | 32.6 | 1792 |
| 4 X 35.0 | 276/0.4 | 1.4 | 36.5 | 2380 |
| 4 X 50.0 | 396/0.4 | 1.6 | 42 | 3635 |
| 4 X 70.0 | 360/0.5 | 1.6 | 49 | 4830 |
| 4 X 95.0 | 475/0.5 | 1.8 | 55 | 6320 |
H07RN-F 5-core cable 450/750V
| Number of cores/cross-sectional area MM2 | Number of shares/diameter per share | Sheath thickness MM | Maximum outer diameter MM | Nominal weight KG/KM |
| 5 X 1.0 | 32/0.20 | 0.8 | 11.0 | 170 |
| 5 X 1.5 | 30/0.50 | 0.8 | 12.3 | 218 |
| 5 X 2.5 | 50/0.25 | 0.9 | 14.5 | 309 |
| 5 X 4.0 | 56/0.30 | 1.0 | 16.9 | 450 |
| 5 X 6.0 | 84/0.30 | 1.0 | 18.8 | 595 |
| 5 X 10.0 | 80/0.40 | 1.2 | 26.5 | 1100 |
| 5 X 16.0 | 126/0.40 | 1.2 | 30 | 1528 |
| 5 X 25.0 | 196/0.40 | 1.4 | 36 | 2200 |
| 5 X 35.0 | 276/0.40 | 1.4 | 40 | 2925 |
H07RN-F multi-core cable 450/750V
| Number of cores/cross-sectional area MM2 | Number of shares/diameter per share | Sheath thickness MM | Maximum outer diameter MM | Nominal weight KG/KM |
| 7 X 1.5 | 30/0.50 | 0.8 | 14.6 | 295 |
| 7 X 2.5 | 50/0.25 | 0.9 | 16.6 | 410 |
| 12 X 1.5 | 30/0.50 | 0.8 | 18.9 | 500 |
| 12 X 2.5 | 50/0.25 | 0.9 | 22 | 720 |
| 19 X 1.5 | 30/0.50 | 0.8 | 22.5 | 715 |
| 19 X 2.5 | 50/0.25 | 0.9 | 26 | 1030 |
| 24 X 1.5 | 30/0.50 | 0.8 | 25 | 900 |
| 24 X 2.5 | 50/0.25 | 0.9 | 29 | 1350 |
| 27 X 1.5 | 30/0.50 | 0.8 | 29 | 1100 |
| 27 X 2.5 | 50/0.25 | 0.9 | 33 | 1521 |
| 37 X 1.5 | 30/0.50 | 0.8 | 29.8 | 1300 |
| 37 X 2.5 | 50/0.25 | 0.9 | 36 | 1900 |