Overview
HANNA acidity meter HI99192, pH range: -2.00 to 16.00pH; PH mV conversion: ± 825 mV; Temperature: -5.0 to 105.0 ° C; 23.0 to 221.0 ° F Hana HANNA acidity meter HI99192, compliant with the FDA Food Safety Modernization Act [FSMA], specifically designed for acidity pH measurement and analysis of samples in the drinking water, food industry, and other industries. The Hana HANNA acidity meter H199192 features a large LCD screen display, allowing you to easily view pH, pH mV, temperature measurement readings, and instrument performance status from multiple angles; Equipped with Sensor Check ™ Function, allowing users to check the electrode status at any time; The built-in amplifier and temperature sensor can be filled with a spherical glass acidity pH electrode. The new design is sturdy and durable, meeting the IP67 waterproof standard (to prevent dust and water immersion). The portable two button design allows you to quickly set and calibrate modes, making the operation of the measuring instrument easier and providing # accurate # measurement results for professional research and production
Product Details
HANNA acidity meter HI99192,pHRange:-2.00 to 16.00pHPH mV conversion:±825 mV;temperature:-5.0 to 105.0°C; 23.0 to 221.0°F
Hana HANNA acidity meter HI99192, compliantFDAFood Safety Modernization ActFSMA】Specially designed forDrinking water and food industryDesign for acidity pH measurement and analysis of waiting samples

HANNA acidity meter H199192, LCDLarge screen display allows you to easily view from multiple anglespH、pH-mV、Temperature measurement readings and instrument performance status;

haveSensor Check ™Function, allowing users to check the electrode status at any time;

Built in amplifier and temperature sensor can be filled in a spherical shapeglassaciditypHElectrode, new design, sturdy and durable, compliant withIP67Standard waterproof standards (to prevent dust and water immersion),

Portable two button design allows you to quickly set and calibrate modes, making the operation of the measuring instrument easier and providing accurate measurement results for professional research and production

HANNA Waterproof Portable pH Temperature Tester HI99192 【 Drinking Water Industry 】

aciditypHTechnical indicators

range-pH

-2.0 to 16.0 pH、-2.00 to 16.00 pH

other

Resolution:0.1 pH、0.01 pH;Accuracy:±0.02

Calibration pH

1-2 point automatic recognition calibration, built-in two sets of acidity standard points:4.01, 7.01, 10.01pH and 4.01, 6.86, 9.18pH

pH-MV conversionIndicator

range

±825 mV (pH-mV)

other

Resolution:1 mV;Accuracy:±1 mV

Temperature technical indicators

range

-5.0 to 105.0°C; 23.0 to 221.0°F

resolution

0.1°C; 0.1°F

accuracy

±0.5°C (up to 60°C), ±1.0°C (other)± 1.0 ° F (up to 140 ° F), ± 2.0 ° F(other)

HANNA acidity meter HI99192 Other technical indicators

Configure electrodes

FC2153Built in amplifier and temperature sensor can be filled in a spherical shapeglassaciditypHelectrode, DIN waterproof quick interface, 1 meter long

temperature compensation

automatic temperature compensation-5.0 to 105.0°C; 23.0 to 221.0°F

standard specification

conform toIP67International standard for waterproofing

Power source

1.5V×3 AAAHigh performance battery, automatically shuts down after 8 minutes without any operation

application environment

0 to 50°C(32 to 122°F); MAX100%RH

Dimension

Size: 154 x 63 x 30 mm (6.1 x 2.5 x 1.2 ");weight:196 g (6.91 oz.)

HANNA Waterproof Portable pH Temperature Tester HI99192

HI99192

Host, FC2153 built-in amplifier and temperature sensor can be filled with spherical glass acidity pH electrode, acidity standard buffer set, standard value @ 25 ° C: 4.01pH, 7.01 pH, HI700601 electrode cleaning solution specification: 20mL × 3, Chinese and English user manual, HI7209913 customized special carrying case

HI99192

Host, FC2153 built-in amplifier and temperature sensor can be filled with spherical glass acidity pH electrode, acidity standard buffer solution set, standard value @ 25 ° C: 4.01pH, 7.01 pH, HI700601 electrode cleaning solution specification: 20mL × 3, shockproof and anti slip customized instrument special protective cover (HI710028 orange or HI710029 blue to be specified when ordering), Chinese and English user manual, HI7209913 customized special carrying case

Electrode/probe



FC2153

Built in amplifier and temperature sensor can be filled with spherical glass acidity pH electrode

Measurement range: 0 to 12 pH, sample temperature range: 0 to 70 ° C (32 to 158 ° F), sample pressure 0.1 bar; DIN waterproof quick interface exclusive: HI99192 acidity tester, built-in signal amplifier and temperature sensor, suitable for acidity pH measurement of drinking water, food and other samples. When using a new electrode, the top protective cover should be removed first and the entire electrode should be checked. If salt crystals are formed in the electrode tip and protective cover due to the evaporation of electrolyte inside the electrode through the dialysis membrane, it does not affect the normal use of the electrode, indicating that the electrode dialysis membrane is normal. Rinse it off with clean water. During transportation, bubbles may form inside the glass ball of the electrode head. In this case, gently shake the electrode like a common mercury thermometer to remove the bubbles. If the electrode glass induction membrane or dialysis membrane head is relatively dry, the electrode can be soaked in HI70300 electrode preservation solution for at least 1 hour to keep the dry glass induction membrane and dialysis membrane moist; Frequent soaking is beneficial for electrodes. Reminder: Do not use distilled water or deionized water to store or soak electrodes, as this will cause electrode sensor failure