-
E-mail
sh@tiantian117.com
-
Phone
18916040785
-
Address
Room 606, Futong Dingqia Building, No. 2300 Yangshupu Road, Shanghai
Running Industrial (Shanghai) Co., Ltd
sh@tiantian117.com
18916040785
Room 606, Futong Dingqia Building, No. 2300 Yangshupu Road, Shanghai
HANNA Waterproof Portable pH Temperature Tester 【 Soil/Agriculture 】 HI99121
pHRange:-2.00 to 16.00pHPH mV conversion:±825 mV;temperature:-5.0 to 105.0°C; 23.0 to 221.0°F
Hana HANNA Waterproof Portable pH Temperature Tester HI99121 is specially designed for acidity pH measurement and analysis of samples in agriculture/landscaping/soil industries|
HANNA Waterproof Portable pH Temperature Tester 【 Soil/Agriculture 】 HI99121 aciditypHTechnical indicators |
|
| range-pH |
-2.0 to 16.0 pH、-2.00 to 16.00 pH |
| other |
Resolution:0.1 pH、0.01 pH;Accuracy:±0.02 |
|
Calibration pH |
1-2 point automatic recognition calibration, built-in two sets of acidity standard points:4.01, 7.01, 10.01pH and 4.01, 6.86, 9.18pH |
|
pH-MV conversionIndicator |
|
| range |
±825 mV (pH-mV) |
| other |
Resolution:1 mV;Accuracy:±1 mV |
|
Temperature technical indicators |
|
| range |
-5.0 to 105.0°C; 23.0 to 221.0°F |
| resolution |
0.1°C; 0.1°F |
| accuracy |
±0.5°C (up to 60°C), ±1.0°C (other)± 1.0 ° F (up to 140 ° F), ± 2.0 ° F(other) |
|
Other technical indicators |
|
| Configure electrodes |
HI12923Built in amplifier and temperature sensor can be filled with glass acidity pH electrode, DIN waterproof quick interface, 1 meter long |
| temperature compensation |
automatic temperature compensation-5.0 to 105.0°C; 23.0 to 221.0°F |
|
standard specification |
conform toIP67International standard for waterproofing |
|
Power source |
1.5V×3 AAAHigh performance battery, automatically shuts down after 8 minutes without any operation |
| application environment |
0 to 50°C(32 to 122°F); MAX100%RH |
| Dimension |
Size: 154 x 63 x 30 mm (6.1 x 2.5 x 1.2 ");weight:196 g (6.91 oz.) |
HI12923
Measurement range: 0 to 12 pH, sample temperature range: -5 to 70 ° C (23 to 158 ° F), sample pressure 0.1 bar; DIN waterproof quick interface exclusive: HI99121, HI98168 acidity tester, built-in signal amplifier and temperature sensor, suitable for acidity pH measurement of samples in agriculture, garden, soil industry, etc. When using a new electrode, the top protective cover should be removed first and the entire electrode should be checked. If salt crystals are formed in the electrode tip and protective cover due to the evaporation of electrolyte inside the electrode through the dialysis membrane, it does not affect the normal use of the electrode, indicating that the electrode dialysis membrane is normal. Rinse it off with clean water. During transportation, bubbles may form inside the glass ball of the electrode head. In this case, gently shake the electrode like a common mercury thermometer to remove the bubbles. If the electrode glass induction membrane or dialysis membrane head is relatively dry, the electrode can be soaked in HI70300 electrode preservation solution for at least 1 hour to keep the dry glass induction membrane and dialysis membrane moist; Frequent soaking is beneficial for electrodes. Reminder: Do not use distilled water or deionized water to store or soak electrodes, as this will cause electrode sensor failure
Preservation/cleaning/filling solution
HI70663
HI70661L [specification: 500mL] and HI700663P [specification: 20mL × 25] are customized specialized soil electrode cleaning solutions. Specially formulated for pH electrodes used in agricultural applications, it can be used for cleaning, treatment, and maintenance of other electrodes in various applications, effectively extending electrode life and ensuring accurate readings. The HI700663P sealed small bag contains an appropriate amount of soil electrode cleaning solution, making it fresh and absolutely pollution-free every time it is used. It is packaged in a unique and lightweight special material bag. The electrode becomes dirty with use, which can result in inaccurate results. Electrode cleaning is a quick and effective step that must be taken, and it should be cleaned after each measurement to ensure that the electrode is not contaminated or blocked. Hanna brand regular electrode cleaning solution is formulated with a special formula, using high-purity chemical reagents and high-quality deionized water. It has been rigorously certified with various measuring tools and containers, and is carefully prepared in a constant temperature and humidity environment that meets the requirements. It adopts a unique tamper proof sealing setting to ensure the quality and freshness of the electrode cleaning solution. It is unopened in a storage environment that meets the requirements and has a shelf life of up to 5 years;
HI70664