Overview
The 26G universal flange radar level gauge outputs 4-20mA/RS485 signals and can measure a maximum distance of up to 70 meters. The horn antenna has been further optimized to add a blowing function. The new microprocessor can perform high-speed signal analysis and processing, and the instrument can measure various solid particles and powders with stability and reliability. The universal flange can be configured to adjust the angle of the material pile to obtain better echo signals.
Product Details
Place of Origin domestic Processing & Customization No

In the field of industrial automation and process control, precise measurement of material storage capacity is a critical step that directly affects the continuity and efficiency of production. The universal flange radar level gauge is widely used as a high-performance measuring tool due to its excellent flexibility and highly reliable measurement results.

The core capability of the universal flange radar level gauge lies in its ability to measure distance through radar waves (usually microwaves). The radar waves emitted by this level gauge can penetrate the air and reflect back to the sensor when encountering the surface of the material. By calculating the time difference between radar wave transmission and reception, the accurate position of the material level can be determined. This non-contact measurement method is very suitable for measuring different forms of materials such as liquids, slurries, particles, and powders.

The design of universal flanges has brought great convenience to the installation and use of radar level gauges. This design allows the radar level gauge to be freely adjusted within a certain angle range, meaning it can be installed in multiple different positions and angles to adapt to various container shapes and installation limitations. This flexibility greatly reduces measurement errors caused by improper installation and improves measurement reliability.

The antenna system emits and receives very short, low-energy microwave pulses. Radar waves propagate at the speed of light. The running time can be converted into a level signal through electronic components. A special time extension method can ensure stable and accurate measurements in a very short amount of time. Even if there are false echoes in complex working conditions, the micro processing technology and debugging software can be used to accurately analyze the echoes of material positions.

1684218408737519.jpg

input

The antenna receives reflected microwave pulses and sends them to the electronic circuit. The microprocessor processes signals and identifies echoes generated by micro pulses on the surface of the material.

Accurate recognition of echo signals can be achieved with millimeter level precision through intelligent software. The distance D from the material surface is proportional to the time interval of the pulse:

D=C*T/2

Among them, C is the speed of light, because the distance E of the empty can,

So, the material/liquid level position L is:

L=E-D

output

By inputting the empty tank height E (=zero), full tank height F (=full range), and some application parameter settings, the instrument is automatically adapted to the measurement environment.

Corresponding to 4-20mA output.

Protection level

How to ensure installation meets IP68 requirements as shown in the picture: Please ensure that the sealing head is not damaged. Please ensure this

1684226742974186.jpg

The instrument cable is not damaged. Please ensure that the cables used comply with the electrical connection specifications. Entering

Please ensure the waterproof performance of the cable sealing head according to the requirement of IP68 protection level. power input

Before connecting the air interface, bend the cable downwards to ensure that water does not flow into the housing. Please tighten the electrical cable as shown in ①

Cable sealing head, see ②. Please use blind plugs to seal unused electrical interfaces, see ③