The HD9008T/9009T series temperature and humidity sensor is a high-precision outdoor meteorological temperature and humidity transmitter, with a compact appearance that is conducive to outdoor installation. The working range of HD9008T/9009T series temperature and humidity sensors is -40-80 ℃.
HD9008T/9009T series temperature and humidity sensors
|
model
|
HD9008TR
|
HD9008TR1/TR2
|
HD9009TR1/TR2
|
|
Transmitter power supply
|
7..30Vdc(4..20mA)
|
7…30Vdc(4…20mA)
|
7…30Vdc(2mA)
|
|
Wen
degree
lose
enter
|
sensor
|
Pt100
|
Pt100
|
Pt100
|
|
measurement range
|
-40…+80℃
|
-40…+80℃
|
-40…+80℃
|
|
precision
|
± 0.1 ℃, ± 0.1% of the reading
|
|
wet
degree
lose
enter
|
sensor
|
Capacitive: 300 pF nom
|
Capacitive: 300 pF nom
|
Capacitive: 300 pF nom
|
|
%RH measurement range
|
5…98%RH
|
5…98%RH
|
5…98%RH
|
|
temperature range
|
-40…+80℃
|
-40…+80℃
|
-40…+80℃
|
|
precision
|
± 2% RH (5... 90%), ± 2.5% RH (other ranges)
|
|
Output
|
output signal
|
Temperature: -40 ℃=4.0mA
+80℃=20.0mA
|
Temperature: Pt100 sensor
2-wire system (HD9008TR1)
4-wire system (HD9008TR2)
|
Temperature: Pt100 sensor
2-wire system (HD9009TR1)
4-wire system (HD9009TR2)
|
|
output signal
|
Humidity: 0% RH=4.0mA
100%RH=20.0mA
|
Humidity: 0% RH=4.0mA
100%RH=20.0mA
|
Humidity: 0% RH=0.0VDC
100%RH=1.0Vdc
|
|
impedance
|
RLmax= (Vdc-7Vdc)/0.022mA
|
RLmax= (Vdc-7Vdc)/0.022mA
|
RINmin=10kΩ
|
|
long-term stability
|
0.2 ℃/year
|
0.2 ℃/year
|
0.2 ℃/year
|
|
Circuit operating temperature
|
-40…. +80℃
|
-40…. +80℃
|
-40…. +80℃
|
|
Sensor operating temperature
|
-40…. +80℃
|
-40…. +80℃
|
-40…. +80℃
|
|
Protection level
|
IP 64
|
IP 64
|
IP 64
|
|
size
|
Ø26×225mm
|
Ø26×225mm
|
Ø26×225mm
|
|
*Long data cable
|
200m
|
200m
|
10m
|
The available models are as follows:
|
HD 9007 A-1
|
12 ring meteorological shielding for transmitters HD 9008TR and HD9009TR.
|
|
HD 9007 A-2
|
16 ring meteorological shielding for transmitters HD 9008TR and HD9009TR, suitable for hot weather.
|
|
HD 9008 TRR
|
configurableDual meteorological temperature and relative humidity transmitter.Measurement range: Temperature -40 ° C...+80 ° C, relative humidity 5 98% RH, 4mA corresponds to -40 ° C and 0% RH, 20mA corresponds to+80 ° C and 100% RH probe Ø 26mm, L=185 millimeters.Power supply 10 .. 40Vdc。
|
|
HD 9008 TR.1
|
Dual meteorological temperature and relative humidity transmitter.It uses a 2wire Pt100 sensor to measure temperature.Measurement range: Relative humidity 5 98% RH, 4mA corresponds to 0% RH, 20mA corresponds to 100% RHpower supply10 . .. 40Vdc.Probe Ø 26mmL = 185 mm。
|
|
HD 9008 TR.2
|
Dual meteorological temperature and relative humidity transmitter.It uses a 4wire Pt100 sensor to measure temperature.Measurement range: Relative humidity 5 98% RH, 4mA corresponds to 0% RH, 20mA corresponds to 100% RHpower supply10 . .. 40Vdc.Probe Ø 26mmL = 185 mm。
|
|
HD 9009 TRR
|
configurableDual meteorological temperature and relative humidity transmitter.Measurement range: Temperature -40 ° C...+80 ° C, relative humidity 5 98% RH, 0VDC corresponds to -40 ° C and 0% RH, 1VDC corresponds to+80 ° C and 100% RH probe Ø 26mm, L=185 millimeters.Power supply 5 .. 35Vdc,2mA。
|
|
HD 9009 TR.1
|
Dual meteorological temperature and relative humidity transmitter.It uses a 4-wire Pt100 sensor to measure temperature.Measurement range: Relative humidity 5 98% RH, 0VDC corresponds to 0% RH, 1VDC corresponds to 100% RHPower supply 5 .. 35Vdc,2mA。Probe Ø 26mmL = 185 mm。
|
|
HD 9009 TR.2
|
Dual meteorological temperature and relative humidity transmitter.It uses a 4-wire Pt100 sensor to measure temperature.Scope of work: Relative humidity 5 98% RH, 0VDC corresponds to 0% RH, 1VDC corresponds to 100% RHPower supply 5 .. 35Vdc,2mA。Probe Ø 26mmL = 185 mm。
|