Welcome Customer !

Membership

Help

Weifang Huaguang High tech Electronics Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Weifang Huaguang High tech Electronics Co., Ltd

  • E-mail

    wfhuaguang@126.com

  • Phone

    13806491159

  • Address

    Jinyu Huangting Business Building, Kuiwen District, Weifang City, Shandong Province (Headquarters of Huaguang High tech Group)

Contact Now

HG30A-2 multifunctional calibrator

NegotiableUpdate on 09/27
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

HG30A-2 multifunctional calibrator, multimeter calibrator, multimeter calibrator, multimeter calibrator, multimeter calibrator, multimeter calibration device 1. Purpose and characteristics: HG30A-2 multifunctional calibrator is an intelligent AC and DC standard voltage and current calibrator (with AC output displaying true RMS)

Product Details

HG30A-2 typeMulti functional calibratorMulti purpose meter calibratorMulti purpose meter calibratorMultimeter calibratorMulti meter calibratorMulti meter calibration device
1、 Purpose and characteristics:
HG30A-2 typeMulti functional calibratorIt is an intelligent AC and DC standard voltage and current calibrator (with AC output displaying true RMS). The instrument is equipped with three display windows, which can simultaneously display the output actual value, percentage, and the full-scale value of the tested meter. The output of the instrument can be set based on the full-scale value of the inspected tablerangeAnd the corresponding step amount can be selected according to the scale of the tested meter. Output adjustment selectablekeyboard(Key) control or potentiometer control. Equipped with digital display, error direct readingrangeFeatures such as width, fine grading, high precision, good stability, and easy use. Suitable for calibration, inspection, and maintenance of four and a half digit multimeters, as well as various pointer type AC and DC voltage and current meters at or below level 0.2 and 0.5; It can also be used as a high stability testing power supply, in conjunction with high-level standard meters, to calibrate 0.1 level current and voltage meters.
2、 Main functions:
1. 51/2The LED displays the output quantity in two ways: actual value and percentage.
2. AdoptingkeyboardControl the increase or decrease of output quantity.keyboardThe control quantity is divided into 100%/N, 10%/N, 1%/N, and 0.1%/N (N is 4, 5, 6, 10, 15).
3External control regulatorIt can control the increase or decrease of output quantity off the machine, and there is a regulator on itkeyboardThere are two configurations of potentiometer, which can be freely converted.
4. The output range of AC and DC voltage is 0-1050V.
5. The output range of AC and DC currents is 0-22A.
6. Communication provides four output frequencies: 50Hz, 60Hz (59.7Hz), 400Hz, 800Hz, 1200Hz, usingcrystal oscillatorEnsure the accuracy and stability of frequency.
7. Output overload can be automatically protected and manually reset.
8. AC 50Hz output can also choose mains synchronization to reduce the impact of the frequency of the tested meter.
9. Clamp meter measurement function: equipped with our standard coil, it can measure current from 0 to 1000A with an error of ± 0.3%.
3、 Technical performance:
1. Stability: AC<fullrange0.02%/5 minutes
DC<Fullrange0.01%/5 minutes
When making precise measurements, the instrument needs to be preheated for two hours.
2. Communication distortion:<0.5%
3. DC ripple factor:<0.05% (at rated output)
4. Output frequency accuracy: 50Hz, 60Hz (59.7Hz), 400Hz, 1KHz < 0.1% (or mains synchronous)
5. Output voltage, current, and median valueresistanceThe range and accuracy are shown in Appendix 1 (23 ℃± 2 ℃, output value greater than 10%)range

Output project output range rated output maximum output
Accuracy
AC/DC voltage 0~300mV 20mA 100mA

Basic error:
DC: ± (0.02% reading+0.03%)range
AC: ± (0.02% reading+0.03%)range
Accuracy is not assessed for AC voltage below 100mV and current below 2mA
1KHz additional error ± 0.05% reading
Voltage additional error:
±0.02mV

0~1V~3V 50mA 100mA
0~5V~10V~30V 100mA 200mA
0~50V~100V~300V 50mA 100mA
0~250V~500V~1000V DC:20mA
AC:40mA
DC:20mA
AC:60mA
AC/DC current 0~100mA DC:3V
AC:36V
0~1A DC:3V
AC:12V
0~20A 1.5V
standardresistance 10. 24, 50, 100, 240, 500 (Ω), 1, 2.4, 5, 10, 24 (k Ω) plus x 1K, x 1 magnification range (10k Ω~24M Ω) 0.25W ±(0.2%+20mΩ)

Note: (1) When the working environment temperature exceeds 23 ℃± 2 ℃, for every 10 ℃ change, the additional error is less than thisrangeBasic error
(2) 50A 1KHz error is ± (0.15% of read value+full)range0.05%)
Appendix (1)
6. Power supply specifications: AC power supply voltage 220V ± 10%, frequency 50Hz ± 1Hz;
7. Working environment: The temperature of the working environment is between 5 ℃ and 35 ℃, and the relative humidity is less than 80%
8. Working hours: continuous
9. Dimensions: 180 × 480 × 480mm3
10. Weight: Approximately 24kg

[Keywords: HG30A-2, HG30A-2 multifunctional calibrator, multifunctional calibrator original text/source link]