Overview
HP3351The series capacitive transmitter has a variable capacitance sensing element that can oscillate, modulate, amplify, and convert the capacitance difference between the measuring diaphragm and the capacitor plate into a standard signal through an oscillator, modulation and demodulation, amplifier amplification, and voltage and current conversion. Can be used for measuring gases, liquids, and vapors.
Main technical parameters
◆ lose Out:4-20mA
◆ electricity Source:24VDCNo load, the transmitter can work in12VDCThe maximum is45VDC
◆ essence Degree: ± of calibration range0.2%,±0.25%,±0.5%,The comprehensive error includes linearity, variability, and repeatability.
◆ Temperature range: The amplifier operates within-29℃-+93℃; Sensitive components work in-40℃-+104℃;
◆ Storage temperature:-50℃-+120℃;
◆ Relative humidity:0-85%;
◆ Positive and negative transfer: Regardless of the output, after positive and negative transfer, the upper and lower limits of the range must not exceed the limit of the range. The maximum negative transfer is the minimum calibration range600%The maximum positive migration is the minimum calibration range500%.
Model selection:
|
content |
code |
Instructions |
||||||||
|
HP3351 |
Product series code |
|||||||||
|
Forms of pressure |
DR |
Micro differential pressure transmitter |
||||||||
|
DP |
|
Differential pressure transmitter |
||||||||
|
△PSquare flow transmitter |
||||||||||
|
HP |
High static pressure differential pressure transmitter |
|||||||||
|
△PSquare flow transmitter |
||||||||||
|
AP |
Absolute pressure transmitter |
|||||||||
|
GP |
Gauge pressure transmitter |
|||||||||
|
LT |
Flange type liquid level transmitter |
|||||||||
|
DP/GP |
Remote differential pressure and pressure transmitter |
|||||||||
|
measurement range |
2 |
0-0.125-1.5KPa |
||||||||
|
3 |
0-1.3-7.5KPa |
|||||||||
|
4 |
0-6.2-37.4 KPa |
|||||||||
|
5 |
0-31.1-186.8 KPa |
|||||||||
|
6 |
0-117-690 KPa |
|||||||||
|
7 |
0-345-2068 KPa |
|||||||||
|
8 |
0-1170-6890 KPa |
|||||||||
|
9 |
0-3450-20680 KPa |
|||||||||
|
0 |
0-6890-41370 KPa |
|||||||||
|
output |
E |
4-20mADC |
||||||||
|
F |
4-20mADC(DRdedicated) |
|||||||||
|
J |
4-20mADCTo input the square root of pressure |
|||||||||
|
Material of liquid receiving parts |
Flange joint |
exhaust/exhaust valve |
Isolation membrane |
Fill with liquid |
||||||
|
22 |
316stainless steel |
316stainless steel |
316stainless steel |
silicone oil |
||||||
|
23 |
316stainless steel |
316stainless steel |
HastelloyC |
silicone oil |
||||||
|
24 |
316stainless steel |
316stainless steel |
Monel |
silicone oil |
||||||
|
25 |
316stainless steel |
316stainless steel |
Tantalum |
silicone oil |
||||||
|
33 |
HastelloyC |
HastelloyC |
HastelloyC |
silicone oil |
||||||
|
35 |
HastelloyC |
HastelloyC |
Tantalum |
silicone oil |
||||||
|
44 |
Monel |
Monel |
Monel |
silicone oil |
||||||
|
Additional features |
M1 |
0-100%Linear indicator table |
||||||||
|
M2 |
0-100%平方根指示表 |
|||||||||
|
M3 |
3LCD digital display |
|||||||||
|
not write |
Without header |
|||||||||
|
B1 |
Pipe bending installation plate |
|||||||||
|
B2 |
Plate bending installation plate |
|||||||||
|
B3 |
Pipe installation safety installation board |
|||||||||
|
not write |
Without installation board |
|||||||||
|
D1 |
The discharge valve is located at the upper part of the pressure chamber |
|||||||||
|
D2 |
The drain valve is located at the lower part of the pressure chamber |
|||||||||
|
C1 |
½-14NPTWeld the rear part of the pressure joint with a diameter of Ø14Pressure pipe | ,|||||||||
|
C2 |
M20×1.5T-shaped male threaded connector |
|||||||||
|
C3 |
M20×1.5T-shaped male threaded connection block with additional T-shaped joint |
|||||||||
|
not write |
½-14NPTConical pipe female thread connector |
|||||||||
|
d |
flameproof typeExdⅡBT4 |
|||||||||