Welcome Customer !

Membership

Help

Yangzhou Husu Electric Power Technology Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Yangzhou Husu Electric Power Technology Co., Ltd

  • E-mail

    HS87605838@163.com

  • Phone

  • Address

    Building 9, Global Financial City, No. 2 Wenchang East Road, Guangling District, Yangzhou City

Contact Now

HSZGF-100KV.2mA DC High Voltage Generator (Integrated Unit)

NegotiableUpdate on 03/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Brief description: The HSZGF-100KV.2mA DC high voltage generator (integrated machine) is a new generation portable DC high voltage generator designed and manufactured according to the new Chinese power grid standard DL/T848.1-2004 "General Technical Conditions for DC High Voltage Generators". It is mainly suitable for conducting DC withstand voltage tests on high-voltage electrical equipment such as zinc oxide lightning arresters, power cables, transformers, generators, etc. in power departments, industrial and mining, metallurgy, steel and other enterprises.
Product Details
brand private label delivery cycle spot

1HSZGF-100KV.2mA DC High Voltage Generator (Integrated Unit)Overview

HSThe ZGF series DC high voltage generator is based on the new Chinese electricity unemployment standardsThe new generation portable DC high voltage generator designed and manufactured according to DL/T848.1-2004 "General Technical Conditions for DC High Voltage Generators". It is mainly suitable for conducting DC withstand voltage tests on high-voltage electrical equipment such as zinc oxide lightning arresters, power cables, transformers, generators, etc. in power departments, industrial and mining, metallurgy, steel and other enterprises.

IIHSZGF-100KV.2mA DC High Voltage Generator (Integrated Unit)Main technical parameters and characteristics

1. Technical features:

Adopting high-frequency voltage doubling circuit, applying PWM pulse width modulation technology and high-power IGBT devices.

Adopting high voltage feedback, the output voltage stability is high, and the ripple coefficient is small ≤ 1%.

Full range smooth voltage regulation, fine voltage regulation accuracy ≤ 0.5%, stability ≤ 1%, voltage and current error 1% (reading ± 0.2KV), current error ± 1 word.

The boost potentiometer boosts the voltage from zero.

● 75%UDC1mAFunction button, convenient for testing zinc oxide lightning arrester, with an accuracy of 1% and a reading of ± 1%.

Overvoltage protection adopts dip code setting, which is clear at a glance with an error of ± 1%.

The double pressure adopts new materials, which are lightweight and sturdy. The exterior is coated with special insulation material, which has good electrical performance and strong moisture resistance.

Folding support feet, with a large diameter area and good stability performance.

● Integrated design, high-voltage grounding cable lead out, convenient for on-site testing.

HSZGF products comply with the technical requirements of DL/T848.1-2004 and have undergone type testing by the Electrical Equipment Quality Inspection and Testing Center of the Ministry of Electric Power, strictly following the enterprise standard before leaving the factory.

2Technical Specifications:

Specifications

Technical Specifications

40/3

60/2

60/5

60/10

80/2

100/2

120/2

120/5

Rated voltage (KV)

40

60

60

60

80

100

120

120

Rated current (mA)

3

2

5

10

2

2

2

5

Rated power (W)

120

120

300

600

160

200

240

600

Chassis weight (kg)

7

2

2

4.5

2

3

3

4.5

Double pressure weight (kg)

integrated

2.5

3

3.8

2.5

4

4

4.5

Double pressure height (mm)

integrated

400

400

500

400

500

500

500

Voltage measurement accuracy

Digital display meter ± (1.0% reading ± 2 words)

Accuracy of current measurement

Digital display meter ± (1.0% reading ± 2 words)

Ripple coefficient

≤1%

voltage stability

Random fluctuation, ≤ 1% when the power supply voltage changes by ± 10%

overload capacity

The no-load voltage can exceed the rated voltage by 10% and be used for ten minutes

The maximum charging current is 1.5 times the rated current

power supply

Single phase AC 50Hz 220V ± 10%

working method

intermittent use

The longest continuous time is 30 minutes

working environment

Temperature: -10~40 ℃

Relative humidity: not exceeding 85% at room temperature of 25 ℃ (no condensation)

Altitude: below 1500 meters

With capacitor

Load capacity

The capacitance of the test sample is unlimited

Can be charged with 1.5 times the rated current

structural characteristics

Epoxy fiberglass electrical insulation double pressure cylinder

Air insulation, no leakage concerns

Characteristics of the operation box

High precision 0.75UDC1mA single touch button (accuracy ≤ 1.0%) zinc oxide lightning arrester test

Overvoltage protection adopts a toggle setting, which is clear at a glance

Place an aluminum alloy box with double voltage on the chassis, and the entire machine can be lifted with one hand