1HSZGF-120KV.5mA DC High Voltage Generator (Split)Overview
HSZGF seriesMedium frequency DC high voltage generator. Suitable for conducting DC high voltage tests on equipment such as zinc oxide lightning arresters, magnetic blown lightning arresters, power cables, generators, transformers, switches, etc. in the power sector and enterprise power departments.
HSZGF seriesThe intermediate frequency DC high voltage tester adopts an intermediate frequency voltage doubling circuit. Apply PWM pulse width modulation technology and high-power IGBT devices. And according to the theory of electromagnetic compatibility, special shielding, isolation, and grounding measures are adopted.HuSu Electric Power Technology Co., LtdThe DC high voltage test has achieved high quality, portability, and the ability to withstand rated voltage discharge without damage.
HSZGF-120KV.5mA DC High Voltage Generator (Split)Adopting voltage feedback. Therefore, the stability of the output voltage is greatly improved, with minimal voltage drift. The high voltage and overvoltage stability are achieved by using digital dial switches, which can intuitively display the set voltage value and have high setting accuracy; Added high precision0.75UDC-1mAThe function buttons have brought great convenience to the measurement of zinc oxide lightning arresters; The output voltage regulation adopts a single multi turn potentiometer with dial indication, which has high adjustment accuracy and simple operation The entire tester has a small volume, light weight, and is easy to operate on site.
IIMain technical performance and characteristics
|
Specifications Technical Specifications |
60/5 |
80/2 |
100/2 |
120/2 |
200/2 |
200/3 |
200/5 |
300/2 |
300/3 |
300/5 |
Rated voltage (KV) |
60 |
80 |
100 |
120 |
200 |
200 |
200 |
300 |
300 |
300 |
Rated current(mA) |
5 |
2 |
2 |
2 |
2 |
3 |
5 |
2 |
3 |
5 |
Rated power (W) |
300 |
160 |
200 |
240 |
400 |
600 |
1000 |
600 |
900 |
1500 |
Voltage measurement accuracy |
Digital Display Meter±(1.0% reading±0.2KV) |
|||||||||
Accuracy of current measurement |
Digital Display Meter±(1.0% reading±0.2KV) |
|||||||||
Ripple coefficient |
≤0.5% |
|||||||||
voltage stability |
Random fluctuations, changes in power supply voltage±At 1.0%≤1% |
|||||||||
overload capacity |
The no-load voltage can exceed the rated voltage by 10% and be used for ten minutes. The maximum charging current is 1.5 times the rated current |
|||||||||
power supply |
Single phase AC 50Hz 220V±10% |
|||||||||
working method |
intermittent use |
|||||||||
The longest continuous time is 30 minutes | ||||||||||
|
working environment |
Temperature: -10 to 40℃ |
|||||||||
Relative humidity: Room temperature is 25Not exceeding 85% at ℃ (no condensation) | ||||||||||
Altitude: below 1500 meters | ||||||||||
Capacity with capacitive load |
The capacitance of the test sample is unlimited |
|||||||||
Can be charged with 1.5 times the rated current | ||||||||||
structural characteristics |
Epoxy fiberglass electrical insulation double pressure cylinder |
|||||||||
Air insulation, no leakage concerns | ||||||||||
Characteristics of the operation box |
High precision 0.75UDC--1mAOne touch button (precision)≤1.0%)Zinc oxide lightning arrester test |
|||||||||
Overvoltage protection adopts dip code setting, which is clear at a glance | ||||||||||
Dual use standard chassis for standing and sleeping, more convenient on site | ||||||||||