HANNA portable pH mV - º C/º F analyzer HI98168Soil/Agriculture
pHRange:-2.000 to 20.000pHMV conversion:±2000.0 mV;temperature-20.0 to 120.0 ° C, -4.0 to 248.0 ° F
Hana HANNA portable pH mV - º C/º F analyzer HI98168 is specially designed for acidity pH measurement and analysis of samples in agriculture/landscaping/soil industries
LCDLarge screen display allows you to easily view from multiple anglespH、pH-mV、Temperature measurement readings and instrument performance status; Having unique characteristicsSensor Check ™Function, allowing users to check the electrode status at any time;
Automatic endpoint locking function, which can lock the # th stable reading on the LCD for easy reading and recording of measurement results;USBData interface,200A data record【100individualpHReading record100Record of mV readings;
GLPFunction, query the latest acidity pH calibration data, up to five automatic recognition calibrations and five custom calibrations, built-in seven standard calibration points, graphicsLCDThe above message can be easily and accurately calibrated
Hana HANNA portable pH mV - º C/º F analyzer H198168New design, sturdy and durable,Built in amplifier and temperature sensor for conical glass aciditypHThe electrode provides convenient and fast settings and calibration modes, making the operation of the measuring instrument easier and providing accurate measurement results for professional research and production.

HI12923
Built in amplifier and temperature sensor can be filled with glass acidity pH electrode
Measurement range: 0 to 12 pH, sample temperature range: -5 to 70 ° C (23 to 158 ° F), sample pressure 0.1 bar; DIN waterproof quick interface exclusive: HI99121, HI98168 acidity tester, built-in signal amplifier and temperature sensor, suitable for acidity pH measurement of samples in agriculture, garden, soil industry, etc. When using a new electrode, the top protective cover should be removed first and the entire electrode should be checked. If salt crystals are formed in the electrode tip and protective cover due to the evaporation of electrolyte inside the electrode through the dialysis membrane, it does not affect the normal use of the electrode, indicating that the electrode dialysis membrane is normal. Rinse it off with clean water. During transportation, bubbles may form inside the glass ball of the electrode head. In this case, gently shake the electrode like a common mercury thermometer to remove the bubbles. If the electrode glass induction membrane or dialysis membrane head is relatively dry, the electrode can be soaked in HI70300 electrode preservation solution for at least 1 hour to keep the dry glass induction membrane and dialysis membrane moist; Frequent soaking is beneficial for electrodes. Reminder: Do not use distilled water or deionized water to store or soak electrodes, as this will cause electrode sensor failure
Preservation/cleaning/filling solution
HI70663
Customized specialized soil electrode cleaning solution
HI70661L [specification: 500mL] and HI700663P [specification: 20mL × 25] are customized specialized soil electrode cleaning solutions. Specially formulated for pH electrodes used in agricultural applications, it can be used for cleaning, treatment, and maintenance of other electrodes in various applications, effectively extending electrode life and ensuring accurate readings. The HI700663P sealed small bag contains an appropriate amount of soil electrode cleaning solution, making it fresh and absolutely pollution-free every time it is used. It is packaged in a unique and lightweight special material bag. The electrode becomes dirty with use, which can result in inaccurate results. Electrode cleaning is a quick and effective step that must be taken, and it should be cleaned after each measurement to ensure that the electrode is not contaminated or blocked. Hanna brand regular electrode cleaning solution is formulated with a special formula, using high-purity chemical reagents and high-quality deionized water. It has been rigorously certified with various measuring tools and containers, and is carefully prepared in a constant temperature and humidity environment that meets the requirements. It adopts a unique tamper proof sealing setting to ensure the quality and freshness of the electrode cleaning solution. It is unopened in a storage environment that meets the requirements and has a shelf life of up to 5 years;

HI70664
Customized specialized cleaning solution for humic sediment electrodes
HI70661L [specification: 500mL] and HI700663P [specification: 20mL × 25] are customized special cleaning solutions for humic sediment electrodes. Specially formulated for the use of pH electrodes in clean humus organic soil materials for agricultural applications, it can be used for cleaning, treatment, and maintenance of other electrodes in various applications, effectively extending electrode life and ensuring accurate readings. The HI700664P sealed small bag contains an appropriate amount of soil electrode cleaning solution, making it fresh and absolutely pollution-free every time it is used. It is packaged in a unique and lightweight special material bag. The electrode becomes dirty with use, which can result in inaccurate results. Electrode cleaning is a quick and effective step that must be taken, and it should be cleaned after each measurement to ensure that the electrode is not contaminated or blocked. Hanna brand regular electrode cleaning solution is formulated with a special formula, using high-purity chemical reagents and high-quality deionized water. It has been rigorously certified with various measuring tools and containers, and is carefully prepared in a constant temperature and humidity environment that meets the requirements. It adopts a unique tamper proof sealing setting to ensure the quality and freshness of the electrode cleaning solution. It is unopened in a storage environment that meets the requirements and has a shelf life of up to 5 years;
Sample processing

HI7051
Customized specialized soil sample preparation solution
Hana's unique soil preparation solution is an electrolyte solution used to measure soil pH. The acidity pH or conductivity of soil is usually measured as a slurry or electrolyte slurry, where a fixed ratio of soil: solvent (solvent is water or electrolyte solution) is selected. The commonly used ratios for acidity pH or conductivity are 1:1, 1:2, or 1:5, where more solvents are used when the soil to be analyzed contains a large amount of organic matter or clay. It is usually preferred to use electrolyte solutions because they are less affected by soil electrolyte concentration and provide more consistent measurements for soils where salt content may fluctuate due to seasonal conditions or crop residues. Using HI7051 solution before measurement can more accurately read the acidity pH or conductivity values of soil samples. Made with high-purity chemical reagents and high-quality deionized water, carefully prepared using rigorously certified measuring tools and containers in a constant temperature and humidity environment that meets requirements, and traceable to NIST standard reference materials (SRM); The soil preparation solution is formulated with a special formula and sealed with a unique tamper proof setting to ensure the quality and freshness of the acidic soil preparation solution.
HI721319
Customized specialized soil pre-treatment loose drill rod
HI721319 customized soil pre-treatment loosening drill rod makes soil testing simple. When starting the measurement, first use a customized soil pre-treatment loose drill rod to drill the soil to a depth of about 20 centimeters or deeper to expose the pure soil and obtain a more accurate sample. Characteristics: Ideal partner for soil measurement; The conical tip is easy to penetrate the topsoil; High quality plastic material is easy to use and clean. Suitable for soil measuring instruments such as HI99121 and HI98168