E-mail
xy@xy-ltd.com
-
Phone
13913335988
-
Address
No. 36 Maoshan Road, Gaochun Development Zone, Nanjing City, Jiangsu Province
Nanjing Xinyao Analytical Instrument Manufacturing Co., Ltd
xy@xy-ltd.com
13913335988
No. 36 Maoshan Road, Gaochun Development Zone, Nanjing City, Jiangsu Province
High frequency infrared carbon sulfur analyzerIntroduction:
The infrared carbon and sulfur analyzer is used in conjunction with a high-frequency induction combustion furnace to quickly and accurately determine the carbon and sulfur elements in metal materials and other materials. It is currently the most accurate and fast carbon and sulfur analysis equipment in China, especially used for the determination of products and aviation supplies.
This device has introduced advanced technology and is a technological product that integrates optics, mechanics, electronics, computers, and analysis technology. It has the characteristics of wide measurement range, strong anti-interference ability, complete functions, easy operation, and accurate and reliable analysis results. Most of the components of the machine are imported, and the overall performance is comparable to imported products.
High frequency infrared carbon sulfur analyzerbaseThis parameter:
Determination of Elements |
: |
Carbon sulfur joint measurement |
Analysis principle |
: |
Electric arc furnace combustion - infrared absorption method detection |
analysis scope |
: |
Carbon: 0.001% -6.0000% Sulfur: 0.001% -0.3500% |
Sample size (solid steel standard) |
: |
Standard 0.5g |
accuracy of analysis |
: |
Carbon is superior to GB/T223.69—1997standard |
Sensitivity (minimum reading) |
: |
C/S:0.1ppm |
analysis time |
: |
25~60Adjustable in seconds, usually35second |
work cycle |
: |
24-hour continuous operation |
electric arc furnace |
: |
1. Arc output power: 1000W; 2.Continuous high-frequency spark ignition and automatic tracking of combustion samples; 3. Gas path: High precision flow controller ensures stable airflow and inlet gas path system |
Dust filter |
: |
0.4-micron ultra microporous metal filter ensures the separation of dust and gas |
detection system |
: |
1. Circuit design: The whole machine adopts a dual CPU upper and lower computer modular design, and the lower computer uses Atmega162 as the control microcontroller. The electronic circuit is highly integrated, stable and reliable; 2. Sampling: High speed 24 bit ADS1224 sampling chip is used, with high sampling accuracy; 3. Communication: The upper and lower computers use USB2.0 interface communication, greatly improving communication speed; 4. Connection: The infrared detection part is connected to the high-frequency furnaceAgilent 1521/2521 high-speed optical fiberConnection (domestic *), combined with multi-level concealed isolation circuit, * eliminates high-frequency interference; 5. Power supply: Industrial grade integrated linear module power supply, stable output, *; 6. Light source: A specially designed new platinum infrared light source with continuous heating and high spectral efficiency; 7. Analysis cell: gold-plated carbon sulfur analysis cell and high-precision pyroelectric infrared detector; 8. Motor: Stepper motor, good thermal stability, continuous service life of 100000 hours. |
High frequency infrared carbon sulfur analyzerSoftware interface:


High frequency infrared carbon sulfur analyzeranalysis software
operating software |
: |
Compiled using Deliph software and operated entirely in Chinese for Windows XP. |
analysis channel |
: |
Provide channel management function, carbon and sulfur channels can be added, deleted, and edited independently without any quantity limit. |
Analysis function |
: |
analysis processDynamic data integration and 20 samples per second have improved the sensitivity and accuracy of analysis; Provide sample management function, which allows editing of sample names and labels, as well as adding and deleting sample names; The software provides a multi-user management system, which allows administrators to set different user permissions. |
display function |
: |
One curve box for carbon and sulfur,Dynamically display real-time data and carbon and sulfur release curves during the analysis process. |
Data processing function |
: |
The analysis results are stored in the ACCESS database, which can store all the data and curves of carbon and sulfur analysis for each time; The analysis results can be freely queried based on various factors such as time, operator, sample name, and identification; Provide multiple functions such as curve/data storage, blank deduction, parameter setting, channel selection, mathematical statistics, result correction, curve comparison, etc; The generation and curve fitting of carbon sulfur working curves can be achieved in software. |
Print function |
: |
The printing modes are diversified, providing two printing modes for laboratory and testing stations, and the printing format can be designed by oneself. |
Self-diagnostic function |
: |
The system diagnostic function can be implemented by software to detect the sealing of the furnace head and gas chamber. |