Product Introduction:
TND and TNS series high-precision fully automatic AC voltage regulators are one of the innovative products of SVC series AC voltage regulators. This voltage regulator adheres to the excellent properties of SVC, and has the characteristics of exquisite appearance, luxurious feeling, and perfect economy.
TND and TNS series single and three-phase high-precision fully automatic AC voltage regulators are composed of contact type autotransformer regulators, servo motors, automatic control circuits, etc. When the grid voltage is unstable or the load changes, the automatic sampling control circuit sends a signal to drive the servo motor, adjust the position of the autotransformer carbon brush, and adjust the output voltage to the rated value and reach a stable state.
This series of voltage regulators has a mains power through function. It has the advantages of multiple varieties, complete specifications, and beautiful appearance. It has the advantages of waveform distortion free, high efficiency, reliable performance, and long-term operation. It is equipped with protection functions such as short delay and overvoltage,
Long delay and undervoltage protection functions can be added according to user needs. The product can be widely used in any electric field and is an ideal voltage regulator to ensure the normal operation of your electrical equipment
Main usage scenarios:
Electronic computers, precision machine tools, computed tomography (CT), precision instruments, testing equipment, elevator lighting, imported equipment, and production lines in industrial and mining enterprises, oil fields, railways, construction sites, schools, hospitals, postal and telecommunications, hotels, scientific research and other departments that require stable power supply voltage. It is also suitable for users at the end of low-voltage distribution networks with low or high power supply voltage and large fluctuation amplitude, as well as electrical equipment with large load changes. It is particularly suitable for all voltage stabilizing electric fields with high requirements for grid waveform.TND
|
Technical parameters of communication voltage regulator: |
input voltagesingle-phase220V±20%or220V±30% |
||||
|
(Wide voltage special customization) |
output voltageSingle-phase voltage220V± |
||||
|
5% |
frequency |
||||
|
50HZ/60HZ |
stabilization timeStep change of input voltage relative to rated value10%Its stability time is ≤ |
||||
|
1S |
work efficiency≥95%(Power level)50KVA |
||||
|
Above) |
voltage regulation accuracy1%-5% |
||||
|
Adjustable |
ambient temperature10﹣℃40-﹢ |
||||
|
℃ |
insulation resistance≥ |
||||
|
2MΩ |
electric strengthPower frequency sine voltage2000V1duration |
||||
|
No breakdown or flashover phenomenon in minutes |
overload capacity |
||||
|
Twice the rated current, maintain for one minute |
Waveform distortion |
||||
|
No additional waveform distortion |
protection function |
||||
|
Equipped with overvoltage, overcurrent, phase loss, phase sequence protection (single-phase without phase loss and phase sequence protection) and mechanical fault protection |
(Single phase) |
) output current(A |
) |
(Single phase) |
) output current(A |
|
) |
TND-0.5KVA |
0.5KVA |
2.3A |
TND-15KVA |
15KVA |
|
68A |
TND-1KVA |
1KVA |
4.5A |
TND-20KVA |
20KVA |
|
91A |
TND-1.5KVA |
1.5KVA |
6.8A |
TND-30KVA |
30KVA |
|
136A |
TND-2KVA |
2KVA |
9.1A |
TND-40KVA |
40KVA |
|
182A |
TND-3KVA |
3KVA |
13.6A |
TND-50KVA |
50KVA |
|
227A |
TND-5KVA |
5KVA |
22.7A |
TND-60KVA |
60KVA |
|
273A |
TND-10KVA |
10KVA |
45.4A |
TND-100KVA |
100KVA |
455ATNS
|
Exchange voltage regulation technical parameters: |
input voltagethree-phase380V±20%or380V±30% |
||||
|
(Wide voltage special customization) |
output voltagethree-phase voltage380V± |
||||
|
5% |
frequency |
||||
|
50HZ/60HZ |
stabilization timeStep change of input voltage relative to rated value10%Its stability time is ≤ |
||||
|
1S |
work efficiency≥95%(Power level)50KVA |
||||
|
Above) |
voltage regulation accuracy1%-5% |
||||
|
Adjustable |
ambient temperature10﹣℃40-﹢ |
||||
|
℃ |
insulation resistance≥ |
||||
|
2MΩ |
electric strengthPower frequency sine voltage2000V1duration |
||||
|
No breakdown or flashover phenomenon in minutes |
overload capacity |
||||
|
Twice the rated current, maintain for one minute |
Waveform distortion |
||||
|
No additional waveform distortion |
protection function |
||||
|
Equipped with overvoltage, overcurrent, phase loss, phase sequence protection (single-phase without phase loss and phase sequence protection) and mechanical fault protection |
(Three phase) |
) output current(A |
) |
(Three phase) |
) output current(A |
|
) |
TNS-1.5KVA |
1.5KVA |
2.3A |
TNS-30KVA |
30KVA |
|
45.4A |
TNS-3KVA |
3KVA |
4.5A |
TNS-40KVA |
40KVA |
|
60.6A |
TNS-4.5KVA |
4.5KVA |
6.8A |
TNS-50KVA |
50KVA |
|
75.7A |
TNS-6KVA |
6KVA |
9.1A |
TNS-60KVA |
60KVA |
|
90.9A |
TNS-9KVA |
9KVA |
13.6A |
TNS-75KVA |
75KVA |
|
113.6A |
TNS-15KVA |
15KVA |
22.7A |
TNS-100KVA |
100KVA |
|
151.5A |
TNS-20KVA |
20KVA |
30.3A |
TNS-150KVA |
150KVA |