This machine is mainly used for measuring the thermal deformation temperature and Vicat softening point temperature of non-metallic materials such as plastics, rubber, nylon, electrical insulation materials, etc. The product complies with the requirements of IS075 (E), IS0306 (E), GB/T8802, GB/T1633, GB/T1634 and other standards. The XRW-300MB model has a sample holder lifting function, which can lift or lower the sample holder at the beginning or end of the test.

Product Details

热变形、维卡软化点测定仪XRW-300B

The XRW-300B hot deformation and Vicat softening point tester uses a PLC programmable controller for temperature adjustment and operates on a Chinese character LCD display. This product is easy to operate, convenient to use, stable in performance, and has high precision. It can also monitor the test temperature and deformation in real-time during the testing process; At the end of the experiment, the system automatically stops heating, and the machine can set a target temperature with temperature protection function. This machine is an essential instrument for self inspection by various quality inspection units, colleges and universities, and enterprises.
This machine is mainly used for measuring the thermal deformation temperature and Vicat softening point temperature of non-metallic materials such as plastics, rubber, nylon, electrical insulation materials, etc. The product complies with the requirements of IS075 (E), IS0306 (E), GB/T8802, GB/T1633, GB/T1634 and other standards.
The XRW-300MB model has a sample holder lifting function, which can lift or lower the sample holder at the beginning or end of the test.
Main technical parameters:
Temperature control range: ambient temperature -300 ℃
Heating rate: (120 ± 10) ℃/h (12 ± 1) ℃/6min
(50±5)℃/h (5±0.5)℃/6min
Temperature indication error: 0.1 ℃
Temperature control accuracy: ± 0.5 ℃
Deformation indication error: ± 0.01mm,
Deformation measurement range: 0-1.5mm
Number of sample racks: 3
Weight of load rod and pallet: 88g
Heating medium: Methyl silicone oil or transformer oil
Cooling method: Natural cooling above 150, water cooling or natural cooling below 150.
Heating power: 4kw

(The above parameters are for reference only, and detailed parameters are based on real devices)