Place of Origin
Overview
Product description: How to determine the photosynthetic rate/photosynthesis analyzer of corn? The SY-1020 photosynthesis analyzer can conveniently and accurately measure the photosynthetic rate of corn at various growth stages. The SY-1020 photosynthesis analyzer adopts two measurement modes: open circuit measurement and closed circuit measurement. A micro electronic flowmeter is used to collect the system flow rate, and the flow rate directly participates in the calculation of the final result.
Product Details

SY-1020Technical indicators of photosynthesis analyzer

CO2Analysis: Non diffusive infraredCO2analyze

Measurement range:0-2000ppm/0-1500ppmoptional

Resolution:0.1ppm

Accuracy: ±3ppm

Air temperature: Swiss imported high-precision digital temperature sensor

Measurement range:-20-60

Resolution:0.1

Error:±0.2

Blade temperature: German Heraeus high-precision platinum resistor

Measurement range:0-60

Resolution:0.1

Error:±0.2

Air humidity: Swiss imported high-precision digital humidity sensor

Measurement range:0-100%

Resolution:0.1%

Error: ≤±3%

Leaf chamber humidity: Swiss imported high-precision digital humidity sensor

Measurement range:0-100%

Resolution:0.1%

Error: ≤±3%

Photosynthetically active radiation(PAR)Silicon photovoltaic cell with correction filter

Measurement range:0-3000µmolm/second

Accuracy: ±5%

Response wavelength range:400700nm

Flowmeter:Micro electronic flowmeter

Measurement range:01.0L/min

Resolution:0.01L/min

mistake Poor:3%

Leaf chamber size:The standard blade chamber size is 55 × 20mm, and other sizes can be customized according to customer needs. The leaf chamber undergoes sandblasting and oxidation treatment, resulting in a smooth and aesthetically pleasing surface.

Working environment: Temperature:0—50

Relative humidity:0-100%(No condensation of water vapor)

electricity Source:DC7.4VLithium battery, capable of continuous operation12hours

Data storage:2GB SDcard

apparent Show:320×240Dot matrix, Chinese interface

body Accumulate:260×260×130mm

heavy Quantity: Host3.5kg;

SY-1020Optional accessories for photosynthesis analyzer

leaf Room: type i(20×20mmWindow area4cm²)Type II(55×10mmwindow area5.5cm²) Type III(φ11.3mmwindow area1cm²)

light Source: External plug and playLEDRed and blue light sources, light intensity range:0-3000µmolm/In seconds,Can manually or automatically set any light intensity value

GPSPositioning: Real time display and saving of latitude and longitude of the measurement location

Group assimilation box: Volume:2Raise. Other sizes can be customized

Soil respirator: volume1.4Raise. Other sizes can be customized

Leaf'sPnAffected by internal physiological factors such as growth period, leaf age, and different parts of leaves, as well as environmental factors such as light, temperature, and waterCO2The impact of wind speed, etc. Therefore, it is very important to master the testing method in order to correctly compare the photosynthetic differences between treatments.