To meet the growing new business needs of customers and meet the requirements of rapid deployment and flexible expansion, Kostar has launched the ITCube series data center solutions. The ITCube solution is designed with the concept of integrated integration, green energy saving, and modularity, helping customers achieve rapid deployment, flexible expansion, efficient operation, and convenient management of next-generation data centers.
Divided into three product solutions based on usage scenarios: IDU (Integrated Data Center Unit) micro unit data center solution, IDM (Integrated Data Center Module) micro module data center solution, and IDR (Integrated Data Center Room) medium to large data center solution.
IDM (Integrated Data Center Module) adopts an integrated solution, and its product modules integrate cabinet systems, power supply and distribution systems, refrigeration systems, monitoring systems, and comprehensive cabling systems. Featuring high-density modularity, high reliability and security, fast and flexible deployment, simple and low consumption, and comprehensive monitoring, it is a new generation integrated medium-sized data center solution.
Quick Deployment
• Integrated small modular data center with IT mainframe cabinet (integrated UPS, power distribution, monitoring), precision air conditioning, and battery cabinet
The solution is productized and modularized, with each component following domestic and international standards. It is plug and play, easy to install, and efficiently configured, greatly shortening the business launch cycle
No need for a professional computer room, can be directly installed on the cement floor of the building, reducing external supporting projects
safe and reliable
Key equipment supports N+1/2N design, with continuous power supply from the battery after power failure, maximizing the stable operation of IT equipment;
A comprehensive monitoring system with multi-level automatic alarm function, providing three alarm disposal methods: local voice alarm, local disposal, telephone voice alarm and network video monitoring, remote disposal, and emergency automatic protection disposal. It can remotely understand the situation inside the cabinet at any time and enhance the protection capability of the cabinet;
The electric sunroof can be opened in conjunction with the fire protection system.
intelligent management
The centralized monitoring platform enables monitoring of the operational status, mains power status, environmental temperature, and other factors of each node's computer room;
Powerful reporting function for precise management of the data center;
365 days a day, 7 x 24 hours a day, unmanned, remote monitoring, and intelligent humanized management. Minimize IT deployment and operation costs to the greatest extent possible.
High Efficiency and Energy Saving
Sealed cold channel (hot channel) design significantly reduces energy consumption for temperature regulation compared to open design;
Adopting row level air conditioning for cooling, configured close to the heat source, to more accurately direct the cold air flow to the desired location;
Adopting efficient modular UPS enables flexible configuration;
High density deployment, with typical rated power of 5kW, 8kW, 10kW, and 15kW per cabinet, to meet different business needs of customers.