Welcome Customer !

Membership

Help

Shanghai Minquan Pump Industry Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products
Product Categories

Shanghai Minquan Pump Industry Co., Ltd

  • E-mail

    ah38852520@qq.com,694757811@qq.com

  • Phone

    13127808058

  • Address

    64, No. 100 Fangde Road, Jiading District, Shanghai

Contact Now

IHG vertical chemical pipeline pump

NegotiableUpdate on 01/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
IHG vertical chemical pipeline pump
Product Details

1、 Product Overview
IHG type vertical single-stage single suction chemical pump has excellent performance, high reliability, long service life, reasonable structure, and beautiful appearance.

2、 Purpose:
IHG type vertical single-stage single suction chemical pump is used for conveying liquids that do not contain solid particles, are corrosive, and have a viscosity similar to water. It is suitable for departments such as petroleum, chemical, metallurgical, power, papermaking, and food and pharmaceutical industries, with a temperature range of -20 ℃ to+105 ℃.

3、 Working conditions:
1. The suction pressure is ≤ 1.6MPa, or the working pressure of the pump system is ≤ 1.6MPa, that is, the pump suction inlet pressure+pump head is ≤ 1.6MPa, and the pump static pressure test pressure is 2.5MPa. Please specify the system working pressure when ordering. When the working pressure of the pump system is greater than 1.6MPa, it should be separately stated when ordering, so that the overcurrent and connection parts of the pump can be made of cast steel materials during manufacturing.
2. Environmental temperature<40 ℃, relative humidity<95%.
3. The volume content of solid particles in the conveyed medium shall not exceed 0.1% of the unit volume, and the particle size shall be less than 0.2mm.
Note: If the medium used is with small particles, please indicate it when ordering so that the manufacturer can use wear-resistant mechanical seals.

4、 Product features:
Smooth operation: The absolute concentricity of the pump shaft and excellent dynamic and static balance of the impeller ensure smooth operation without any vibration.
Drip proof: Hard alloy seals made of different materials ensure that there is no leakage during the transportation of different media.
Low noise: The water pump supported by two low-noise bearings runs smoothly, with almost no noise except for weak motor noise.
Low failure rate: The structure is simple and reasonable, and the key parts are of world-class quality; Matching, the whole machine's fault free working time is greatly improved.
Easy maintenance: Replacing seals and bearings is simple and convenient.
More land saving: The exit can be arranged in three directions: left, right, and up, which is convenient for pipeline layout and installation, saving space.

Model meaning:

Performance parameter table

Pump model flow Head lift
(m)
efficiency
(%)
rotational speed
(r/min)
Motor Power
(kw)
Cavitation residue
(m)
(m 3 /h) (l/s)
15-80 1.5 0.42 8 34 2800 0.18 2.3
20-110 2.5 0.69 15 34 2800 0.37 2.3
20-160 2.5 0.69 32 25 2900 0.75 2.3
25-110 4 1.11 15 42 2900 0.55 2.3
25-125 4 1.11 20 36 2900 0.75 2.3
25-125A 3.6 1.0 16 35 2900 0.55 2.3
25-160 4 1.11 32 32 2900 1.5 2.3
25-160A 3.7 1.03 28 31 2900 1.1 2.3
32-125 5 1.39 20 44 2900 0.75 2.3
32-125A 4.5 1.25 16 43 2900 0.5 2.3
40-100 6.3 1.75 12.5 54 2900 0.55 2.3
40-100A 5.6 1.56 10 52 2900 0.37 2.3
40-125 6.3 1.75 20 46 2900 1.1 2.3
40-125A 5.6 1.56 16 45 2900 0.75 2.3
40-160 6.3 1.75 32 40 2900 2.2 2.3
40-160A 5.9 1.64 28 39 2900 1.5 2.3
40-160B 5.5 1.53 24 38 2900 1.1 2.3
40-200 6.3 1.75 50 33 2900 4.0 2.3
40-200A 5.9 1.64 44 31 2900 3.0 2.3
40-200B 5.3 1.47 36 29 2900 2.2 2.3
40-250 6.3 1.75 80 28 2900 7.5 2.3
40-250A 5.9 1.64 70 28 2900 5.5 2.3
40-250B 5.5 1.53 60 27 2900 4.0 2.3
40-100(I) 12.5 3.47 12.5 62 2900 1.1 2.3
40-100(I)A 11 3.05 10 60 2900 0.75 2.3
40-125(I) 12.5 3.47 20 58 2900 1.5 2.3
40-125(I)A 11 3.05 16 57 2900 1.1 2.3
40-160(I) 12.5 3.47 32 52 2900 3.0 2.3
40-160(I)A 11.7 3.25 28 51 2900 2.2 2.3
40-160(I)B 10.4 2.89 22 50 2900 1.5 2.3
40-200(I) 12.5 3.47 50 46 2800 5.5 2.3
40-200(I)A 11.7 3.25 44 45 2900 4.0 2.3
40-200(I)B 10.6 2.94 36 44 2900 3 2.3
40-250(I) 12.5 3.47 80 38 2900 11 2.3
40-250(I)A 11.6 3.22 70 38 2900 7.5 2.3
40-250(I)B 10.8 3.0 60 37 2900 7.5 2.3
40-250(I)C 10.0 2.78 52 36 2900 5.5 2.3
50-100 12.5 3.47 12.5 62 2900 1.1 2.3
50-100A 11 3.05 10 60 2900 0.75 2.3
50-125 12.5 3.47 20 58 2900 1.5 2.3
50-125A 11 3.05 16 57 2900 1.1 2.3
50-160 12.5 3.47 32 52 2900 3.0 2.3
50-160A 11.7 3.25 28 51 2900 2.2 2.3
50-160B 10.4 2.89 22 50 2900 1.5 2.3
50-200 12.5 3.47 50 46 2900 5.5 2.3
50-200A 11.7 3.25 44 45 2900 4.0 2.3
50-200B 10.6 2.94 36 44 2900 3 2.3
50-250 12.5 3.47 80 38 2900 11 2.3
50-250A 11.6 3.22 70 38 2900 7.5 2.3
50-250B 10.8 3.0 60 37 2900 7.5 2.3
50-250C 10.0 2.78 52 36 2900 5.5 2.3
50-100(I) 25 6.94 12.5 69 2900 1.5 2.5
50-100(I)A 22.3 6.19 10 67 2900 1.1 2.5
50-125(I) 25 6.94 20 68 2900 3.0 2.5
50-125(I)A 22.3 6.19 16 66 2900 2.2 2.5
50-160(I) 25 6.94 32 63 2900 4.0 2.5
50-160(I)A 23.4 6.5 28 62 2900 4.0 2.5
50-160(I)B 21.6 6.0 24 58 2900 3.0 2.5
50-200(I) 25 6.94 50 58 2900 7.5 2.5
50-200(I)A 23.5 6.53 44 57 2900 7.5 2.5
50-200(I)B 21.8 6.06 38 55 2900 5.5 2.5
50-250(I) 25 6.94 80 50 2900 15 2.5
50-250(I)A 23.4 6.5 70 50 2900 11 2.5
50-250(I)B 21.6 6.0 60 49 2900 11 2.5
50-315(I) 25 6.94 125 40 2900 30 2.5
50-315(I)A 23.7 6.58 113 40 2900 22 2.5
50-315(I)B 22.5 6.25 101 39 2900 18.5 2.5
50-315(I)C 20.6 5.72 85 38 2900 15 2.5

Structural diagram

Serial Number Component Name Serial Number Component Name
1 pump body 5 coupling
2 impeller 6 Motor support
3 mechanical seal 7 pump cover
4 electrical machinery

Fault phenomenon
Reason for malfunction Troubleshooting
1. The water pump is not producing water aThe inlet and outlet valves are not open, the inlet and outlet pipelines are blocked, and the impeller of the flow channel is blocked; a、 Check and remove blockages;
b、 The motor is running in the wrong direction and has a slow speed due to phase loss; b、 Adjust the direction of the motor and tighten the motor wiring.
c、 Leakage of suction pipe; c、 Tighten all sealing surfaces to eliminate air leaks;
d、 The pump is not filled with liquid and there is air inside the pump chamber; d、 Fill with liquid and open the exhaust valve to exhaust all air;
e、 Insufficient imported water supply, high suction capacity, and leaking bottom valve; e、 Shutdown, inspection, and adjustment (this phenomenon is prone to occur when using grid connected water pipes or with suction ports);
f、 Excessive pipeline resistance and improper pump selection. f、 Reduce pipeline bends and reselect pumps.
2. Insufficient water pump flow a、 First, check the cause according to 1; a、 First, press 1 to exclude.
b、 The pipeline and pump flow passage impeller are partially blocked, scale accumulates, and the valve opening is insufficient; b、 Remove the blockage and readjust the valve opening;
c、 Low voltage; c、 Voltage stabilization;
d、 Impeller wear. d、 Replace the impeller;
3. Excessive power a、 Exceeding the rated flow usage; a、 Adjust the flow rate and turn down the outlet valve;
b、 Excessive suction; b、 Reduce;
c、 Wear of pump bearings; c、 Replace bearings;
4. Noise vibration a、 Unstable pipeline support; a、 Stabilize the pipeline;
b、 Liquid mixed with gas; b、 Increase suction pressure and exhaust;
c、 Generating cavitation; c、 Reduce the vacuum degree;
d、 Bearing damage; d、 Replace bearings;
e、 The motor is running under overload and overheating. e、 Adjust according to 5;
5. Motor overheating a、 Excessive traffic and overloaded operation; a、 Close the outlet valve;
b、 Rubbing; b、 Check and eliminate;
c、 Motor bearings are damaged; c、 Replace bearings;
d、 Insufficient voltage; d、 Voltage stabilization;
6. Water pump leakage a、 Mechanical seal wear; a、 Replace;
b、 The pump body has sand holes or fractures; b、 Welding repair or replacement;
c、 The sealing surface is uneven; c、 Repair;
d、 Loosening of installation bolts; d、 Fastening;
Similar Product Recommend