1.Product description:
Shanghai Meixu Measurement and Control MX-WD-03 SeriesIndustrial temperature sensorThe product is developed specifically for the hydraulic field and engineering machinery with limited installation space. It uses imported temperature measuring components, packaging technology, and sophisticated assembly processes to ensure the quality and performance of the product. the seriesIndustrial temperature sensorIt has many advantages such as fast thermal response time, strong heat resistance, high pressure resistance, earthquake resistance, multiple temperature models to choose from, and diversified installation methods. It transmits the sensed temperature levels to display instruments, recording instruments, electronic regulators, and other instruments through connecting wires to read temperature values. It can also be directly converted into amplified signals and connected to PLC.
2. Product features:
☛Diversified structural forms, simple assembly, and easy replacement
☛Strong anti-interference ability, high long-term stability, and high mechanical strength
☛Good seismic performance and high measurement accuracy
☛Large measurement range (-200 ℃~1800 ℃)
☛Fast thermal response time, long service life, and good pressure resistance performance
☛Small installation space required
3. Application Fields:
☛Temperature monitoring in the field of industrial automation
☛Food and beverage processing industry
☛Temperature Monitoring in Petrochemical Industry、water treatment
☛environmental protection industry、Monitoring of wastewater and exhaust gas temperature
☛Hydraulic field、construction machinery
4.Main technical specifications of commonly used thermocouples:
thermocouple/Obstacle category |
graduation mark |
Measuring range |
allowable deviationt |
K |
800-1200 |
±2.5 or±0.75%t |
|
Ni/Ch-Cu |
E |
600-800 |
±2.5 or±0.75%t |
Cu |
T |
350-400 |
±2.5 or±0.75%t |
Fe-Cu |
J |
600-700 |
±2.5 or±0.75%t |
Pt |
PT100 |
0-600 |
±1 or±0.75%t |
Cu |
CU50 |
-50~100 |
±2.5 or±0.75%t |
5.Common specification drawings:

6.Technical Specifications:
Model Description: |
MX-WD-03 |
Temperature measuring element: |
N,R,K,E,J,T,PT100,CU50 |
Accuracy level: |
Level I:+/- (0.15+0.2%t); IILevel:+/-(0.3+0.5%t) |
temperature range |
-20°~0~1300℃ |
Supply voltage: |
24(12~36)VDC (Default transmitter),10(6~12)VDC (mVDefault signal thermocouple) |
Output signal: |
4-20mA(Two wire system)A2); Thermocouple direct writing |
Material of protective tube: |
304Stainless steel(F1);316Stainless steel(F2); Titanium material(F3) |
Connection type: |
No fixed device, threaded connection, movable flange, fixed flange, card sleeve thread (Customer selection) |
Wiring form: |
Hesman leads out |
7.Selection Guide:
model |
range |
output |
Installation fixed form |
Insertion depth and diameter |
other |
MX-WD-03 |
(-20-150) |
4-20MA |
M20*1.5 |
100/6 |
none |
Example of ordering: |
MX-WD-03-(-20-150)-A2-F1-M20-100/6 |
||||