Intelligent dual flange liquid level transmitter

NegotiableUpdate on 12/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
WRS3351DP intelligent dual flange liquid level transmitter: used to prevent the medium in the pipeline from directly entering the transmitter. The pressure sensing diaphragm is connected to the transmitter through a capillary tube filled with fluid.
Product Details

1WRS3351DPIntelligent dual flange liquid level transmitterIntroduction
Used to prevent the medium in the pipeline from directly entering the transmitter, the pressure sensing diaphragm is connected to the transmitter by a capillary tube filled with fluid. It is used to measure the liquid level, flow rate, and pressure of liquids, gases, or vapors, and then convert them into 4-20mA DC signal output. After the WRS3351DP remote transmission flange differential pressure transmitter is equipped with a remote transmission sealing device, it becomes the WRS3351DP double flange differential pressure transmitter, which can be used for measuring pressure, differential pressure, and liquid level. It can communicate with the HART handheld device for setting and monitoring.

IIWRS3351DPIntelligent dual flange liquid level transmitterSuitable occasions
Can eliminate the occurrence of pressure pipe leakage and pollution of the surrounding environment; It can avoid the tedious work of frequently replenishing isolation fluid due to the instability of measurement signals when using isolation fluid. Applicable to the following measurement and control situations:
1. Viscous media at high temperatures;
2. Medium that is prone to crystallization;
3. Settling media with solid particles or suspended solids;
4. Highly corrosive or toxic media.

3、 Product Features
1. Simulate "online operation" assessment for each transmitter to ensure stable and reliable operation under extreme environmental temperature, medium temperature, and working pressure (including positive pressure or vacuum);
2. Adopting a "dynamic profile" remote transmission membrane structure, the membrane will not be damaged after overload; The accuracy will not change after long-term work;
3. The occurrence of oil leakage was investigated by using a filling system with full fusion welding and rigid sealing structure;
4. A novel capillary coupling component is designed to provide reliable protection for the capillary, making it less prone to breakage during on-site use;
5. A variety of remote transmission devices in terms of variety, form, and size, as well as a rich variety of filling fluids, can meet the measurement needs of various occasions;
6. We can provide various special needs products, including high temperature, high vacuum, fast response, and unequal long capillary (difference ≤ 4.5 meters) remote differential pressure transmitters.

4、 Technical parameters
Applicable medium: acid, alkali, salt or any medium that is non corrosive to polytetrafluoroethylene
Output signal: 4-20mA two-wire system with digital signal based on HART protocol superimposed, user can choose linear or square root output
Power supply: 12-45VDC
Measurement range: 0-0.2-20m
Measurement accuracy: ± 0.2% and ± 0.5% of the calibration range
Pressure bearing range: negative pressure, normal pressure, high pressure (below 32MPa)
Start time:<2 seconds, no preheating required
Working temperature: -50~240 ℃
Environmental temperature -20~75 ℃
Protection level: IP65
Explosion proof type: explosion-proof ExdII BT4-6, intrinsic safety ExiaII CT5
Static pressure influence: HP class zero position error: ± 0.5% maximum range limit, corrected by zero adjustment for 32MPa under pipeline pressure;
DP class zero position error: For 14MPa, ± 0.1% maximum range limit or ± 0.25% maximum range limit (range code 3), correction is given by zeroing under pipeline pressure
Electromagnetic radiation impact: 0.05% maximum range value, receiving radiation frequency of 27-500MHz, test field strength of 3V/m
On site display: analog display 0-, digital display, on-site depth
Vibration effect: ± 0.05%/g when vibrating at 200Hz in any direction
Installation position: The diaphragm is not installed vertically, which may result in a zero point error of less than 0.24KPa, but it can be corrected by adjusting the zero point
Fixed method: thread installation M20 × 1.5, M27 × 2 flange installation DN15, DN25, DN50, DN80, DN100, etc

5、 Remote transmission device form
1. Flat remote transmission device; 2. Threaded installation remote transmission device;
3. Flange mounted remote transmission device; 4. Insert the cylindrical remote transmission device.