E-mail
442365872@qq.com
-
Phone
15000321529
-
Address
No. 488 Guanghua Road, National Economic Development Zone, Xiaokunshan Town, Songjiang District, Shanghai
Shanghai Meixu Measurement and Control Technology Co., Ltd
442365872@qq.com
15000321529
No. 488 Guanghua Road, National Economic Development Zone, Xiaokunshan Town, Songjiang District, Shanghai
1 Intelligent temperature and humidity sensorMX-WD-07GseriesWidely used in fields such as communication, building construction, automation, etc. that require temperature and humidity monitoring. Connect current to the sensor, separate the temperature measurement component from the signal output. Performance is safe, reliable, aesthetically pleasing, and easy to install.Intelligent temperature and humidity sensorThe outer shell is waterproof, and the internal circuit board also has a special waterproof function. Low power, wide range environmental temperature measurement, stable and reliable operation. Due to its silicone rubber sealing structure and excellent waterproof performance, it can also be applied in harsh environments.
2.Application field
1In the fields of plastics, chemical fibers, and mechanical engineering:
2Various water and air pressure measurements;
3Medical and healthcare applications, pharmaceuticals;
4Chemical environmental protection and wastewater evaporation;
5In the fields of desulfurization, denitrification, and industrial control.
3. Product features
1. On site LCD display;
2. Good seismic resistance and high-precision measurement;
3. Wide range temperature measurement (-40 ℃~120 ℃);
4. Fast thermal response and long usage time;
5. 10-30V wide voltage supply, easy to install.
4.Overall outline drawing

5.Detailed specifications
model: |
MX-WD-07G |
measurement range: |
temperature:-40℃~100℃(customizable);humidity range:0~100% RH |
output signal: |
4-20mA(Two line system code 2);RS485(Two line system code 4) |
precision range: |
temperature accuracy:±0.5℃(default);Humidity accuracy:±3%RH(default) |
power supply: |
24(12~36)VDC (amplify the signal) |
storage environment: |
-40℃~80℃ |
display: |
LCDLCD digital display |
install: |
Wall installation;plug-in |
housing material: |
Cast aluminum explosion-proof shell |
6.Selection reference
model |
range |
output |
power supply |
MX-WD-07G |
0-80°/0-80% |
RS485 |
24VDC |
for example: |
MX-WD-07-(0-80)/80%-4 |
||
7.agreement content
1.1 Power supply and485signal:
Wide voltage input12-24VWhen connected485Please pay attention when using the signal lineA\\BTwo wires cannot be connected, and all devices inside the motor cannot be connected incorrectly.
1.2 Wiring Xiangshen:
terminal |
Instructions |
|
power supply |
5P-1 |
V+(24V DC) |
5P-2 |
V- |
|
communication |
5P-4 |
485-A |
5P-5 |
485-B |
|
temperature conversion |
2P-T |
temperature4-20mA output |
Humidity conversion |
2P-H |
humidity4-20mA output |
1.3 485 On site wiring instructions:
When multiple devices are connected to the motor simultaneously485Model equipment, multiple requirements to be noted for on-site wiring:
2.communication protocol:
2.1 Basic communication parameters:
encoding |
8Bit binary |
data bit |
8-bit |
parity bit |
none |
stop bit |
1bit |
Error verification |
CRC |
Baud rate |
2400bit/s、4800bit/s、9600 bit/s Can be set, default:9600bit/s |
2.2Network Communication Protocol-RTU The communication protocol and format are as follows:
Initial structuree ≥4byte
address code= 1byte
function code= 1byte
data area= Nbyte
Error checking= 16bitCRCencoding
Construct deadline≥4byte
address code:As the transmitter address, it functions in the communication network (factory default)0×01)
function code: USES, Function Code:0x03 (register data)
data area:For special communication data
CRCcode:Two byte checksum
address code |
function code |
Register starting address |
Register length |
Low bit of verification code |
High bit of verification code |
1byte |
1byte |
2byte |
2byte |
1byte |
1byte |
address code |
function code |
Effective byte count |
Data Zone 1 |
Second data area |
第Ndata area |
verification code |
1byte |
1byte |
1byte |
2byte |
2byte |
2byte |
2byte |
2.3register address:
register address |
PLC Or configure the address |
Content |
operation |
0000 H |
40001 |
humidity |
read-only |
0001 H |
40002 |
temperature |
read-only |
Information Framework:
address code |
function code |
starting address |
data length |
Low bit of verification code |
High bit of verification code |
0x01 |
0x03 |
0x00 0x00 |
0x00 0x02 |
0xC4 |
0x0B |
Response frame:
address code |
function code |
Return the number of valid bytes |
humidity value |
temperature value |
Low bit of verification code |
High bit of verification code |
0x01 |
0x03 |
0x04 |
0x02 0x92 |
0xFF 0x9B |
0x5A |
0x3D |
Temperature calculation:
When the temperature is below 0 ℃ The temperature data is uploaded in the form of a complement code.
temperatureFF9BH(hexadecimal)= -101 =>temperature = -10.1℃
Humidity calculation:
humidity292 H (hexadecimal)= 658 =>humidity= 65.8%RH
3. Common problems and solutions:
3.1The device cannot connect toPLCOr computerPossible reasons for the end
1)There is more than one computerCOMport,The selected port is incorrect
2)Equipment address error or duplicate address (default for factory)1)
3)Baud rate, checksum, data bit or stop bit error
4) 485Motor not connected orABTwo wires connected backwards
5)The equipment cable is too long or requires close range power supply
6) USB to 485Driver not installed or damaged
7)Equipment damage