Intelligent temperature and humidity sensor

NegotiableUpdate on 01/05
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The MX-WD-07G series of temperature and humidity intelligent sensors are widely used in communication, building construction, automation and other fields that require temperature and humidity monitoring. Connect current to the sensor, separate the temperature measurement component from the signal output. Performance is safe, reliable, aesthetically pleasing, and easy to install. The outer shell is waterproof, and the internal circuit board also has a special waterproof function. Low power, wide range environmental temperature measurement, stable and reliable operation. Due to its silicone rubber sealing structure and excellent waterproof performance, it can also be applied in harsh environments.
Product Details

1 Intelligent temperature and humidity sensorMX-WD-07GseriesWidely used in fields such as communication, building construction, automation, etc. that require temperature and humidity monitoring. Connect current to the sensor, separate the temperature measurement component from the signal output. Performance is safe, reliable, aesthetically pleasing, and easy to install.Intelligent temperature and humidity sensorThe outer shell is waterproof, and the internal circuit board also has a special waterproof function. Low power, wide range environmental temperature measurement, stable and reliable operation. Due to its silicone rubber sealing structure and excellent waterproof performance, it can also be applied in harsh environments.

2.Application field

1In the fields of plastics, chemical fibers, and mechanical engineering:

2Various water and air pressure measurements;

3Medical and healthcare applications, pharmaceuticals;

4Chemical environmental protection and wastewater evaporation;

5In the fields of desulfurization, denitrification, and industrial control.

3. Product features

1. On site LCD display;

2. Good seismic resistance and high-precision measurement;

3. Wide range temperature measurement (-40 ℃~120 ℃);

4. Fast thermal response and long usage time;

5. 10-30V wide voltage supply, easy to install.


4.Overall outline drawing


温湿度智能传感器


5.Detailed specifications

model

MX-WD-07G

measurement range

temperature-40℃~100℃(customizable)humidity range0~100% RH

output signal

4-20mATwo line system code 2);RS485Two line system code 4

precision range

temperature accuracy±0.5℃(default)Humidity accuracy±3%RH(default)

power supply

24(12~36)VDC (amplify the signal)

storage environment

-40℃~80℃

display

LCDLCD digital display

install:

Wall installation;plug-in

housing material

Cast aluminum explosion-proof shell

6.Selection reference

model

range

output

power supply

MX-WD-07G

0-80°/0-80%

RS485

24VDC

for example

MX-WD-07-(0-80)/80%-4

7.agreement content

1.1 Power supply and485signal:

Wide voltage input12-24VWhen connected485Please pay attention when using the signal lineA\\BTwo wires cannot be connected, and all devices inside the motor cannot be connected incorrectly.

1.2 Wiring Xiangshen:


terminal

Instructions

power supply

5P-1

V+24V DC

5P-2

V-

communication

5P-4

485-A

5P-5

485-B

temperature conversion

2P-T

temperature4-20mA output

Humidity conversion

2P-H

humidity4-20mA output

1.3 485 On site wiring instructions:

When multiple devices are connected to the motor simultaneously485Model equipment, multiple requirements to be noted for on-site wiring:

2.communication protocol:

2.1 Basic communication parameters:

encoding

8Bit binary

data bit

8-bit

parity bit

none

stop bit

1bit

Error verification

CRC

Baud rate

2400bit/s4800bit/s9600 bit/s Can be set, default:9600bit/s

2.2Network Communication Protocol-RTU The communication protocol and format are as follows:

Initial structuree ≥4byte

address code= 1byte

function code= 1byte

data area= Nbyte

Error checking= 16bitCRCencoding

Construct deadline≥4byte

address code:As the transmitter address, it functions in the communication network (factory default)0×01

function code: USES, Function Code:0x03 (register data)

data area:For special communication data

CRCcode:Two byte checksum

address code

function code

Register starting address

Register length

Low bit of verification code

High bit of verification code

1byte

1byte

2byte

2byte

1byte

1byte

address code

function code

Effective byte count

Data Zone 1

Second data area

Ndata area

verification code

1byte

1byte

1byte

2byte

2byte

2byte

2byte

2.3register address:

register address

PLC Or configure the address

Content

operation

0000 H

40001

humidity

read-only

0001 H

40002

temperature

read-only

Information Framework

address code

function code

starting address

data length

Low bit of verification code

High bit of verification code

0x01

0x03

0x00 0x00

0x00 0x02

0xC4

0x0B

Response frame

address code

function code

Return the number of valid bytes

humidity value

temperature value

Low bit of verification code

High bit of verification code

0x01

0x03

0x04

0x02 0x92

0xFF 0x9B

0x5A

0x3D

Temperature calculation:

When the temperature is below 0 The temperature data is uploaded in the form of a complement code.

temperatureFF9BH(hexadecimal)= -101 =>temperature = -10.1

Humidity calculation:

humidity292 H (hexadecimal)= 658 =>humidity= 65.8%RH

3. Common problems and solutions:

3.1The device cannot connect toPLCOr computerPossible reasons for the end

1)There is more than one computerCOMport,The selected port is incorrect

2)Equipment address error or duplicate address (default for factory)1

3)Baud rate, checksum, data bit or stop bit error

4) 485Motor not connected orABTwo wires connected backwards

5)The equipment cable is too long or requires close range power supply

6) USB to 485Driver not installed or damaged

7)Equipment damage



Similar Product Recommend