DM1632Intelligent multi-channel voltage and current meter
1Intelligent voltage and current collectorFeatures
Wide temperature LCD display in Chinese/English
18 channel DC voltage and current isolation input, isolation voltage 400V.
Differential input can measure positive and negative voltage and current.
Multiple AD acquisition, refresh all channels in 1 second.
Equipped with a relay for public alarm output.
Two independent RS485 serial ports can be used simultaneously without interfering with each other.
Isolation and lightning protection RS485 interface, standard MODUBS-RTU communication protocol.
2、 Main technical indicators for multi-channel acquisition of DC voltage and current

IIIIntelligent voltage and current collectorTerminal wiring
Note: Multiple customized inputs, subject to the wiring diagram on the product.

4、 Product selection
Multi channel acquisition of DC voltage and currentDM1632- □□□-□□-□()
①②③ ④⑤ ⑥⑦

Note: 1. The selection must be complete, and any functions not selected must also be filled in with code.
Selection example: DM1632-T3518-R1S-D
DM1632-T35(9)36(9)18-R1S-D, 9-channel voltage and 9-channel current.
5、 Operating instructions
(1) The key functions of the instrument panel are touch sensitive keys, please do not press them hard when using.

(2) Parameter setting
In working mode, the instrument displays multiple channel measurement values simultaneously. Press and hold the SET key for about 1 second to enter the password input screen. In the set state, display parameter prompt information and set values. If there is no button operation within about 60 seconds during the setting process, it will automatically exit the setting state and enter the running state. After setting a parameter, press the SET key to confirm and enter the next parameter setting state. During the setting process, long press the ◄ key for about 2 seconds to return to the previous parameter setting state.


6、 Communication instructions
(1) This product is equipped with RS232 and RS485 interfaces for direct communication with computers. The RS485 standard communication distance is 1.5km, and multiple instruments can be mounted. The RS232 standard communication distance is 15m, and only one instrument can be attached. The TXD, RXD, and GND of the RS232 interface are respectively connected to the second, third, and fifth pins of the computer serial port. The data format consists of 1 start bit, 8 data bits, no checksum, and 1 stop bit. To avoid communication conflicts, the instruments are all in listening mode. The computer sends a command to a certain instrument at a specified address, and then waits for a period of time for the instrument to respond. After the instrument receives the correct command, it sends out the data. After sending, the instrument is in listening mode again. In the same system, instrument addresses cannot be the same, and baud rates must be consistent.
(2) Adopting the standard Modbus RTU communication protocol, using the 03, 04, and 06 function numbers. When using the configuration software touch screen, select a PLC with standard Modbus or Modicon (* * Kang) device, Modbus RTU address type, function number 3X or 4X can be used, register address starts from the first, data is a signed 16 bit integer, and when using Configuration King registers (i.e. 4x001, 4x000), other configuration software may start from 3x001 or 3x000. Users need to handle the decimal places according to their actual situation. It is recommended for user programming to define signed integer data, or by calculation. When the data is greater than 0X7FFF (decimal 32767), subtract the data from 65536 and then take a negative value. For example, if the communication transmission data is 0XFF9C (decimal 65436), 65536-65436=100, then take a negative value of -100. Professional algorithms can also use reverse addition 1. For long integer data such as cumulants, the data value is equal to high-order x 65536+low order, or the data type can be selected as long integer (Long), and the system will automatically calculate the cumulant. Register 4x1024 is a single precision floating-point number type for measurement values, following standard IEEE754, such as 0x42CAFBCF corresponding to 101.4918.


(4) Example: Read the first data value with address 1: Send data as 01 03 00 00 01 84 0A, where 01 is the lower level machine address, 03 is the function number, 00 and 00 are the register start addresses, 00 and 01 represent reading a number, and 84 and 0A are CRC check codes; The returned data is 01 03 02 E8 B8 FA. In the returned data, 01 is the instrument address, 03 is the function number, 02 is the number of data, and the measured values of 03 and E8 correspond to integers of 1000. The user determines the decimal point position according to the situation; B8 and FA are verification codes. If you want to read two data, you can send 01 03 00 00 02 C4 0B.
Products with communication indicator lights (COM) will flash when the lower computer receives the correct command.
The product comes with a universal address of 248, which can be used to read when the address is unclear.
7、 Warranty
If it is a manufacturing quality problem caused by the factory, the instrument will be repaired free of charge from the date of leaving the factory. If the damage is caused by improper storage and use, the repair cost will be charged. The warranty period is eighteen months.
8、 Alarm instructions
This instrument can be equipped with one relay, and each channel can be set with alarms or multiple channels can share a set of alarm parameters for common alarms. Using two parameters of alarm value hysteresis to avoid frequent relay actions.
Upper limit alarm: If the measured value is higher than the alarm value, it will be in an alarm state. If the measured value is lower than the alarm value minus the difference value, the alarm state will be released;
Lower limit alarm: If the measured value is lower than the alarm value, it will be in an alarm state. If the measured value is higher than the alarm value plus the hysteresis value, the alarm state will be released;
Turn off alarm value: Prohibit alarm. The alarm status values of each channel can be read through communication.
Bomint Chengdu Technology Co., Ltd. is committed to the field of industrial automation control, integrating research and development, production, sales, and service. It is a professional manufacturer of intelligent measurement and control instruments and meters. Based on the accumulation and continuous innovation of more than 20 years of R&D experience in the company, we have formed our own intellectual property brand bomite ® The series of products includes recorders, single channel measuring and controlling instruments, multi-channel inspection instruments, flow integrators, PID controllers, weighing instruments, isolation barriers, voltage and current meters, frequency tachometers, timer counters, signal sources, and dozens of other series. The products are widely used in various industries and scientific research sites such as chemical, power, and petroleum.
Bomint always adheres to the concept of "striving for excellence and craftsmanship spirit", constantly exploring and innovating, with quality as the core and Industry 4.0 as the guide. We operate with integrity, provide attentive service, and wholeheartedly provide users with high-quality automation instruments and meters.