Italy Hana HI98292G Multi Parameter Water Quality Analysis and Measurement Instrument

NegotiableUpdate on 01/30
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Italian Hana HI98292G Multi parameter Water Quality Analysis Tester Model: HI98292G/HI98292GT After sales Service: 1. Our company promises that all products sold are original and genuine from the factory. 2. This product comes with a nationwide warranty, with a warranty period of 1 year (excluding consumables); 3. If there are any product quality issues during the warranty period, free repairs will be provided; Provide long-term technical support outside the warranty period, no maintenance fees will be charged, only basic accessory fees and related fees will be charged at discretion; 4. For all product after-sales issues, please contact our company directly. Our after-sales service team will respond and handle them within 24 hours.
Product Details

Italy Hana HI98292G Multi Parameter Water Quality Analysis and Measurement Instrument

HI98292GThe dual data storage built-in GPS multi parameter (15 items) water quality analysis analyzer is suitable for rapid measurement of 15 indicators including acidity, oxidation-reduction, pH mV conversion, conductivity, total solid solubility, resistivity, dissolved oxygen, saturated dissolved oxygen, salinity, seawater specific gravity, atmospheric pressure, ammonia nitrogen, chloride, nitrate, temperature, etc. The old models are HI98295 and HI98297
Unique GPS positioning system and T.I.S. electronic tag system, intelligent memory electrode and dual capacity data storage function of the host, chart curve display, USB data interface, automatic endpoint locking.

Features:

New ergonomic design, IP67 waterproof and anti slip design, oversized background light, chart display function, cost-effectiveness;
GPS positioning system, accurate positioning and measurement coordinates, innovative map preview function, effectively improving data management;
Multi parameter integrated electrode design enables rapid simultaneous measurement of 16 important water quality indicators, full screen display, and clear visibility;
• Unique fast calibration function, automatic error diagnosis function, automatic recognition of range and electrode type, easy replacement of measurements;
Ion selective electrode method for measuring ammonia nitrogen, chloride and nitrate, with built-in DO compensation pressure device;
Intelligent memory electrode and dual capacity data storage function of the host, USB data interface, professional data analysis and management software;
• Unique Fast Tracker ™ T. I.S. electronic tag system, with no omissions in data information and the function of displaying data curves in screen charts;
The electrode is designed with a stainless steel protective shell that meets IP68 waterproof standards, suitable for measuring harsh environments such as pipelines or deep wells;
Anti electromagnetic signal interference, automatic endpoint locking, ensuring measurement reliability, accuracy, and adaptability to a wide range of fields;
Equipped with a built-in rechargeable battery, power adapter, or car charger, it is an ideal choice for mobile monitoring and accurate laboratory analysis.

Italy Hana HI98292G Multi Parameter Water Quality Analysis and Measurement Instrument

Technical Specifications:

Acidity pH and pH/mV conversion technical indicators
Measurement range: 0.00 to 14.00pH/± 600.0 mV
Resolution: 0.01 pH/0.1 mV; Measurement accuracy: ± 0.02 pH/± 0.5 mV
Calibration mode: up to three automatic recognition calibrations and one custom calibration, with five built-in standard calibration points
(4.01、6.86、7.01、9.18、10.01pH)
Oxidation reduction ORP/mV technical indicators
Measurement range: ± 2000.0 mV
Resolution: 0.1 mV; Measurement accuracy: ± 1.0 mV
Calibration mode: Single point custom calibration
ISEIonic concentration technical indicators
Ammonia nitrogen measurement range: 0.02 to 200 mg/L (ppm) as N
Chloride measurement range: 0.6 to 200 mg/L (ppm)
Nitrate (nitrogen) measurement range: 0.62 to 200 mg/L (ppm) as N
解析度: 0.01 mg/L(≤1 mg/L)、0.1 mg/L(>1 mg/L)
Measurement accuracy: Reading ± 5% or 2 mg/L, whichever is greater
Calibration mode: 1. 2-point automatic recognition calibration, built-in standard calibration points: 10 mg/L (ppm), 100 mg/L (ppm)
Electrical conductivity EC technical indicators
0.0 to 200.0 mS/cm (without temperature compensation, actual conductivity: 0.0 to 400.0 mS/cm)
0 to 9999 µS/cm、10.00 to 99.99 mS/cm、100.0 to 400.0 mS/cm
Resolution: 1 µ S/cm, 0.01mS/cm, 0.1mS/cm
Measurement accuracy: Reading ± 1% or 1 µ S/cm, whichever is greater
Calibration mode: automatic recognition of single point calibration, user-defined calibration, built-in six conductivity standard calibration points
84µS/cm、1413µS/cm、5.00mS/cm、12.88mS/cm、80.0mS/cm、111.8mS/cm
Electrical resistivity technical indicators
0 to 999999 Ω•cm、0 to 1000.0 kΩ•cm、0 to 1.000.0 MΩ•cm
Total Solid Solubility TDS Technical Index
0 to 400000 mg/L (ppm) (the maximum value depends on the TDS conversion coefficient)
0 to 9999 mg/L(ppm)、10.00 to 99.99 g/L(ppt)、100.0 to 400.0 g/L(ppt)
解析 度: 1 mg/L(ppm)、0.01 g/L(ppt)、0.1 g/L(ppt)
Measurement accuracy: Reading ± 1% or 1 mg/L (ppm), whichever is greater
Actual salinity technical indicators
Measurement range: 0.00 to 70.00 PUS; Resolution: 0.01 PUS
Measurement accuracy: Reading ± 2% or 0.01 PUS, whichever is greater
Calibration mode: Single point custom calibration
Technical indicators for seawater specific gravity
Measurement range: 0.0 to 50.0 σ t, σ 0, σ 15;
Resolution: 0.1 σ t, σ 0, σ 15; Measurement accuracy: ± 1 σ t, σ 0, σ 15
Calibration mode: Based on conductivity or salinity calibration
Dissolved oxygen and saturated dissolved oxygen technical indicators
Measurement range: 0.00 to 50.00 mg/L (ppm), 0.0 to 500.0%
Resolution: 0.01 mg/L (ppm), 0.1%
Measurement accuracy:
≤ 30.00 mg/L: reading ± 1.5% or 0.10 mg/L (ppm), whichever is greater,>30.00 mg/L: reading ± 3%
≤ 300.0%: reading ± 1.5% or 1.0%, whichever is greater,>300.0%: reading ± 3%
Calibration mode: single point or double point calibration automatic calibration, zero point or air automatic 100% calibration
Atmospheric pressure technical indicators
450 to 850 mm Hg、17.72 to 33.46 in Hg、600.0 to 1133.2 mbar
8.702 to 16.436 psi、0.5921 to 1.1184 atm、60.00 to 113.32 kPa
Resolution: 0.1 mm Hg, 0.01 in Hg, 0.1 mbar, 0.001 psi, 0.0001 atm, 0.01 kPa
Measurement accuracy: ± 3 mm Hg @ ± 15 ° C
Calibration mode: Single point custom calibration
Temperature technical indicators
-5.00 to 55.00°C、23.00 to 131.00°F、268.15 to 328.15K
Resolution: 0.01 ° C, 0.01 ° F, 0.01K, measurement accuracy: ± 0.15 ° C, ± 0.27 ° F, ± 0.15K
Calibration mode: Single point custom calibration
Other technical indicators
GPS positioning function: 12 satellites search and locate within a 30 meter positioning range
Temperature compensation: Automatic temperature compensation, -5.00 to 55.00 ° C, 23.00 to 131.00 ° F
data storage
Host: 44000 measurement data storage, recording interval setting: 1 second to 3 hours, USB data interface
Electrode: 140000 individual measurement data or 35000 all measurement data storage, USB data interface
Waterproof standard: Host: IP67, multi parameter electrode: IP68
Other features: FastTracker ™ TAG ID
Power mode: 1.5V × 4AAA battery or 1.2V × 4 rechargeable battery, AC230V/12DC power adapter
Operating environment: 0 to 50 ° C (32 to 122 ° F), RH max 100%
Size and weight: Host size: 221 x 115 x 55 mm, Host weight: 750g

HI98292GTDual data storage built-in GPS multi parameter water quality analysis and measurement instrument

HI98292GTThe dual data storage built-in GPS multi parameter (16 items) water quality analysis analyzer is suitable for rapid measurement of 16 indicators including acidity, oxidation-reduction, pH mV conversion, conductivity, total solid solubility, resistivity, turbidity, dissolved oxygen, saturated dissolved oxygen, salinity, seawater specific gravity, atmospheric pressure, ammonia nitrogen, chloride, nitrate, temperature, etc. The old models are HI98296 and HI98298
Unique GPS positioning system and T.I.S. electronic tag system, intelligent memory electrode and dual capacity data storage function of the host, chart curve display, USB data interface, automatic endpoint locking

HI98292GTDual data storage built-in GPS multi parameter water quality analysis and measurement instrumentFeatures:

New ergonomic design, IP67 waterproof and anti slip design, oversized background light, chart display function, cost-effectiveness;
GPS positioning system, accurate positioning and measurement coordinates, innovative map preview function, effectively improving data management;
Multi parameter integrated electrode design enables rapid simultaneous measurement of 16 important water quality indicators, full screen display, and clear visibility;
• Unique fast calibration function, automatic error diagnosis function, automatic recognition of range and electrode type, easy replacement of measurements;
Ion selective electrode method for measuring ammonia nitrogen, chloride and nitrate, in compliance with ISO 7027 standard for turbidity determination, with built-in DO compensation pressure device;
Intelligent memory electrode and dual capacity data storage function of the host, USB data interface, professional data analysis and management software;
• Unique Fast Tracker ™ T. I.S. electronic tag system, with no omissions in data information and the function of displaying data curves in screen charts;
The electrode is designed with a stainless steel protective shell that meets IP68 waterproof standards, suitable for measuring harsh environments such as pipelines or deep wells;
Anti electromagnetic signal interference, automatic endpoint locking, ensuring measurement reliability, accuracy, and adaptability to a wide range of fields;
Equipped with a built-in rechargeable battery, power adapter, or car charger, it is an ideal choice for mobile monitoring and accurate laboratory analysis.


HI98292GTDual data storage built-in GPS multi parameter water quality analysis and measurement instrumentTechnical Specifications:

Acidity pH and pH/mV conversion technical indicators
Measurement range: 0.00 to 14.00pH/± 600.0 mV
Resolution: 0.01 pH/0.1 mV; Measurement accuracy: ± 0.02 pH/± 0.5 mV
Calibration mode: up to three automatic recognition calibrations and one custom calibration, with five built-in standard calibration points
(4.01、6.86、7.01、9.18、10.01pH)
Oxidation reduction ORP/mV technical indicators
Measurement range: ± 2000.0 mV
Resolution: 0.1 mV; Measurement accuracy: ± 1.0 mV
Calibration mode: Single point custom calibration
ISEIonic concentration technical indicators
Ammonia nitrogen measurement range: 0.02 to 200 mg/L (ppm) as N
Chloride measurement range: 0.6 to 200 mg/L (ppm)
Nitrate (nitrogen) measurement range: 0.62 to 200 mg/L (ppm) as N
解析度: 0.01 mg/L(≤1 mg/L)、0.1 mg/L(>1 mg/L)
Measurement accuracy: Reading ± 5% or 2 mg/L, whichever is greater
Calibration mode: 1. 2-point automatic recognition calibration, built-in standard calibration points: 10 mg/L (ppm), 100 mg/L (ppm)
Electrical conductivity EC technical indicators
0.0 to 200.0 mS/cm (without temperature compensation, actual conductivity: 0.0 to 400.0 mS/cm)
0 to 9999 µS/cm、10.00 to 99.99 mS/cm、100.0 to 400.0 mS/cm
Resolution: 1 µ S/cm, 0.01mS/cm, 0.1mS/cm
Measurement accuracy: Reading ± 1% or 1 µ S/cm, whichever is greater
Calibration mode: automatic recognition of single point calibration, user-defined calibration, built-in six conductivity standard calibration points
84µS/cm、1413µS/cm、5.00mS/cm、12.88mS/cm、80.0mS/cm、111.8mS/cm
Electrical resistivity technical indicators
0 to 999999 Ω•cm、0 to 1000.0 kΩ•cm、0 to 1.000.0 MΩ•cm
Total Solid Solubility TDS Technical Index
0 to 400000 mg/L (ppm) (the maximum value depends on the TDS conversion coefficient)
0 to 9999 mg/L(ppm)、10.00 to 99.99 g/L(ppt)、100.0 to 400.0 g/L(ppt)
解析 度: 1 mg/L(ppm)、0.01 g/L(ppt)、0.1 g/L(ppt)
Measurement accuracy: Reading ± 1% or 1 mg/L (ppm), whichever is greater
Actual salinity technical indicators
Measurement range: 0.00 to 70.00 PUS; Resolution: 0.01 PUS
Measurement accuracy: Reading ± 2% or 0.01 PUS, whichever is greater
Calibration mode: Single point custom calibration
Technical indicators for seawater specific gravity
Measurement range: 0.0 to 50.0 σ t, σ 0, σ 15;
Resolution: 0.1 σ t, σ 0, σ 15; Measurement accuracy: ± 1 σ t, σ 0, σ 15
Calibration mode: Based on conductivity or salinity calibration
Turbidity (compliant with ISO7027 standard) technical indicators
Measurement range: 0.0 to 99.9 FNU, 100 to 1000 FNU
解析度: 0.1 FNU、1 FNU
Measurement accuracy: Reading ± 2% or 0.3 FNU, whichever is greater
Calibration mode: automatic recognition and custom calibration, built-in standard calibration points: 0, 20, 200 FNU
Dissolved oxygen and saturated dissolved oxygen technical indicators
Measurement range: 0.00 to 50.00 mg/L (ppm), 0.0 to 500.0%
Resolution: 0.01 mg/L (ppm), 0.1%
Measurement accuracy:
≤ 30.00 mg/L: reading ± 1.5% or 0.10 mg/L (ppm), whichever is greater,>30.00 mg/L: reading ± 3%
≤ 300.0%: reading ± 1.5% or 1.0%, whichever is greater,>300.0%: reading ± 3%
Calibration mode: single point or double point calibration automatic calibration, zero point or air automatic 100% calibration
Atmospheric pressure technical indicators
450 to 850 mm Hg、17.72 to 33.46 in Hg、600.0 to 1133.2 mbar
8.702 to 16.436 psi、0.5921 to 1.1184 atm、60.00 to 113.32 kPa
Resolution: 0.1 mm Hg, 0.01 in Hg, 0.1 mbar, 0.001 psi, 0.0001 atm, 0.01 kPa
Measurement accuracy: ± 3 mm Hg @ ± 15 ° C
Calibration mode: Single point custom calibration
Temperature technical indicators
-5.00 to 55.00°C、23.00 to 131.00°F、268.15 to 328.15K
Resolution: 0.01 ° C, 0.01 ° F, 0.01K, measurement accuracy: ± 0.15 ° C, ± 0.27 ° F, ± 0.15K
Calibration mode: Single point custom calibration
Other technical indicators
GPS positioning function: 12 satellites search and locate within a 30 meter positioning range
Temperature compensation: Automatic temperature compensation, -5.00 to 55.00 ° C, 23.00 to 131.00 ° F
Data storage:
Host: 44000 measurement data storage, recording interval setting: 1 second to 3 hours, USB data interface
Electrode: 140000 individual measurement data or 35000 all measurement data storage, USB data interface
Waterproof standard: Host: IP67, multi parameter electrode: IP68
Other features: FastTracker ™ TAG ID
Power mode: 1.5V × 4AAA battery or 1.2V × 4 rechargeable battery, AC230V/12DC power adapter
Operating environment: 0 to 50 ° C (32 to 122 ° F), RH max 100%
Size and weight: Host size: 221 x 115 x 55 mm, Host weight: 750g