Italy Hana HI991300 microcomputer measuring instrument
Hana HI991300/HI991301
Capable of measuring acidity pH, conductivity EC, total solid solubility TDS, and temperature - ° C, with a sturdy electrode casing design and a wide range of applications;
1. Built in solid-state amplifier, capable of eliminating transient electrical noise interference;
2. Built in temperature sensor, automatic temperature compensation
3. Unique Ampere Conductivity Electrode, Accurate and Reliable Measurement
4. Multi parameter electrodes are easy to clean, convenient for cleaning and maintenance after measurement
5. Unique and durable dialysis membrane can effectively extend the service life of the instrument. When the dialysis membrane ages, it can be pulled out
characteristic:
New exterior design, dual row large LCD display, fast response speed, cost-effectiveness;
Humanized operation interface, stable indicator signs, two key simple operation, convenient operation;
Simultaneously measure and display pH (EC/TDS) and ° C measurement, with quick switching between pH, EC, and TDS;
1-2 point acidity automatic recognition calibration, built-in 2 sets of acidity standard calibration points;
pH4.01、 7.01, 10.01 and pH 4.01, 6.86, 9.18
Single point automatic identification and calibration of conductivity and total solid solubility, with built-in standard points;
EC:1413 µS/cm; TDS: 1382ppm or 1500ppm
Automatic temperature compensation ensures measurement accuracy and precision in different environments;
The battery replacement is simple and fast, and the BEPS low battery error prevention system avoids erroneous measurements;
Suitable for providing laboratory level measurement results even in harsh environments.
Italy Hana HI991300 microcomputer measuring instrument
Technical Specifications:
measurement range
Acidity pH: 0.00 to 14.00 pH
Conductivity EC: 0 to 3999 µ S/cm
Total solid solubility TDS: 0 to 2000 ppm (mg/L)
Temperature: 0.0 to 60.0 ° C (32.0 to 140.0 ° F)
Resolution
Acidity pH: 0.01 pH
Conductivity EC: 1 µ S/cm
Total solid solubility TDS: 1 ppm (mg/L)
Temperature: 0.1 ° C, 0.1 ° F
Measurement accuracy (@ 20 ° C)
Acidity pH: ± 0.01 pH
Conductivity EC: ± 2% F.S
Total solid solubility TDS: ± 2% F.S
Temperature: ± 0.5 ° C, ± 1 ° F
Calibration mode:
1-2Automatic identification and calibration of acidity points, with 2 built-in acidity standard calibration points
pH4.01、 7.01, 10.01 and pH 4.01, 6.86, 9.18
Single point automatic identification and calibration of conductivity and total solid solubility, with built-in standard points
EC:1413 µS/cm; TDS:1382 ppm(mg/L) 或1500 ppm(mg/L)
Temperature compensation:
Acidity pH: Automatic temperature compensation
EC-TDS: Compensation coefficient ß=2.4%/° C adjustable, incremental value: 0.1
TDS conversion factor: adjustable from 0.45 to 1.00, incremental value: 0.1, default value: 0.5
Power mode: 3 x 1.5V AAA batteries, automatically shut down after 8 minutes of inactivity in measurement mode
Operating environment: 0 to 50 ° C (32 to 122 ° F), RH max 100%
Size and weight: Host size: 152 x 58 x 30 mm, Host weight: 205g
Standard configuration:
HI991300
Host, HI1288 built-in temperature sensor and amplifier pH EC combination electrode, PH-EC-TDS standard solution set, standard values (@ 25 ° C): pH4.01, pH7.01, 1413 µ S/cm, 1382mg/L, conventional electrode cleaning solution, specification 20mL × 5, Chinese and English user manual, HI721015 carrying case
HI991300D
Host, HI1288 host, HI1288 built-in temperature sensor and amplifier pH EC combination electrode, HI74710-31H customized PH-EC-TDS standard solution kit [Standard values (@ 25 ° C): pH4.01, pH7.01, pH10.01, 1413 µ S/cm, 1382mg/L, conventional electrode cleaning solution and conventional electrode preservation solution, specification 100mL × 7], Chinese English user manual, HI721015 carrying case
HI991301High range microcomputer pH EC TDS - ℃ measuring instrument
HI1288Built in temperature sensor with multi parameter electrode
Multi parameter electrodes can measure acidity pH, conductivity EC, total solid solubility TDS, and temperature - ° C, with a sturdy electrode shell design and a wide range of applications;
A、 Built in solid-state amplifier, capable of eliminating transient electrical noise interference;
B、 Built in temperature sensor, automatic temperature compensation
C、 Unique Ampere Conductivity Electrode, Accurate and Reliable Measurement
D、 Multi parameter electrodes are easy to clean, convenient for cleaning and maintenance after measurement
E、 Unique and durable dialysis membrane can effectively extend the service life of the instrument. When the dialysis membrane ages, it can be pulled out
HI991301High range microcomputer pH EC TDS - ℃ measuring instrumentcharacteristic:
New exterior design, dual row large LCD display, fast response speed, cost-effectiveness;
Humanized operation interface, stable indicator signs, two key simple operation, convenient operation;
Simultaneously measure and display pH (EC/TDS) and ° C measurement, with quick switching between pH, EC, and TDS;
1-2 point acidity automatic recognition calibration, built-in 2 sets of acidity standard calibration points;
pH4.01、 7.01, 10.01 and pH 4.01, 6.86, 9.18
Single point automatic identification and calibration of conductivity and total solid solubility, with built-in standard points;
EC:12880 µS/cm; TDS:6.44 ppt(g/L)
Automatic temperature compensation ensures measurement accuracy and precision in different environments;
The battery replacement is simple and fast, and the BEPS low battery error prevention system avoids erroneous measurements;
Suitable for providing laboratory level measurement results even in harsh environments.
HI991301High range microcomputer pH EC TDS - ℃ measuring instrumentTechnical Specifications:
measurement range
Acidity pH: 0.00 to 14.00 pH
Conductivity EC: 0.00 to 20.00 mS/cm
Total solid solubility TDS: 0.00 to 10.00pppt (g/L)
Temperature: 0.0 to 60.0 ° C (32.0 to 140.0 ° F)
Resolution
Acidity pH: 0.01 pH
Conductivity EC: 0.01 mS/cm
Total solid solubility TDS: 0.01 ppt (m/L)
Temperature: 0.1 ° C, 0.1 ° F
Measurement accuracy (@ 20 ° C)
Acidity pH: ± 0.01 pH
Conductivity EC: ± 2% F.S
Total solid solubility TDS: ± 2% F.S
Temperature: ± 0.5 ° C, ± 1 ° F
Calibration mode:
1-2Automatic identification and calibration of acidity points, with 2 built-in acidity standard calibration points
pH4.01、 7.01, 10.01 and pH 4.01, 6.86, 9.18
Single point automatic identification and calibration of conductivity and total solid solubility, with built-in standard points
EC:12880 µS/cm; TDS:6.44 ppt(g/L)
Temperature compensation:
Acidity pH: Automatic temperature compensation
EC-TDS: Compensation coefficient ß=2.4%/° C adjustable, incremental value: 0.1
TDS conversion factor: adjustable from 0.45 to 1.00, incremental value: 0.1, default value: 0.5
Power mode: 3 x 1.5V AAA batteries, automatically shut down after 8 minutes of inactivity in measurement mode
Operating environment: 0 to 50 ° C (32 to 122 ° F), RH max 100%
Size and weight: Host size: 152 x 58 x 30 mm, Host weight: 205g
Standard configuration:
HI991301
Host, HI1288 built-in temperature sensor and amplifier pH EC combination electrode, PH-EC-TDS standard solution set, standard values (@ 25 ° C): pH4.01, pH7.01, 12880 µ S/cm, 6.44g/L, conventional electrode cleaning solution, specification 20mL × 5, Chinese English user manual, HI721015 carrying case
HI991301D
Host, HI1288 host, HI1288 built-in temperature sensor and amplifier pH EC combination electrode, HI74710-30H customized PH-EC-TDS standard solution kit [Standard values (@ 25 ° C): pH4.01, pH7.01, pH10.01, 12880 µ S/cm, 6.44g/L, conventional electrode cleaning solution and conventional electrode preservation solution, specification 100mL × 7], Chinese English user manual, HI721015 carrying case