Welcome Customer !

Membership

Help

Tianjin Cable Factory Rubber Cable Factory
Custom manufacturer

Main Products:

ybzhan>Products

JHS underwater rubber sheathed cable 3 * 16 JHS waterproof cable 3 * 25

NegotiableUpdate on 12/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
JHS underwater rubber sheathed cable 3 * 16 JHS waterproof cable 3 * 25 $r $n $r $nJHS 300/500V and below waterproof rubber sheathed cable 4, 6, 10 $r $n16, 25, 35 $r $n50, 70, 95 1, 3 $r $n4 TL/Q 13-91 for connecting AC power
Product Details

'JHS underwater rubber sheathed cable 3 * 16 JHS waterproof cable 3 * 25

Waterproof rubber sheathed cables 4, 6, 10 for JHS 300/500V and below submersible motors
16. 25, 35
50, 70, 95 1, 3
4 TL/Q 13-91 is used for connecting AC voltage 300/500V and below to the front water motor. One end of the waterproof rubber sleeve cable is in water, and the long-term allowable working temperature does not exceed 65 ℃
Flat waterproof rubber sheathed cables 16, 25 for JHSB submersible motors
35, 50 3 TL/J 13-91 is suitable for transmitting electricity through water and electricity pumps before drainage, with a long-term allowable working temperature not exceeding 85 ℃
Structural characteristics of mining rubber sheathed cables:
1: Conductive wire core. The flexibility requirements are highest for electric drill cables and mining machine cables; The following measures are taken for the wire structure:
1. Use softer small-diameter copper single wires, bundled and twisted at small intervals. The bending and twisting properties of the entire cable are also affected by the insulation and sheath structure, so it cannot be assumed that the finer the single wire, the smaller the pitch, the better.
2. Adopting co directional bundle twisting and compound twisting can improve flexibility.
3. In order to facilitate the relative sliding of wires in the insulation layer and facilitate installation and maintenance. The single wire of drill cables and small section mining machine cables should be tinned, and the large section mining machine cables should be insulated with paper tape outside the wire.

JHS underwater rubber sheathed cable 3 * 16 JHS waterproof cable 3 * 25

2: The insulation layer requires sufficient electrical insulation performance
1. Use rubber with a rubber content of not less than 35%
2. The insulation thickness is thicker than that of general rubber sheathed cables
3. Use rubber with good electrical properties and adopt good extrusion technology (such as extrusion vulcanization continuous production line)
3: Shielding layer
The use of non-conductive rubber as the shielding layer should ensure that its transition resistance meets the standard requirements to ensure reliable operation of the relay protection system in case of accidents.

4: Pad core
1. The pad core should fully serve as a buffer when the cable is subjected to impact or compression, while not being too large in outer diameter. Require a reasonable design to fill the gaps between insulated core wires.
2. The mechanical performance should not be lower than the requirements of insulating rubber.
3. It should not adhere to the insulated wire core.
5: Cable structure
1. Use smaller pitch multiples to improve the flexibility of the cable.
To ensure the mechanical strength of the ground wire core, the cross-section of the ground wire core is larger than that of general cables. For small cross-section products, the same cross-section as the main conduit is used.

Our main products include mining cables, power cables, control cables, welding machine cables, silicone rubber cables, marine cables, computer cables, instrument cables, high-voltage cables, etc. Our factory also undertakes the research and development of special models and specifications of wire and cable products. In order to promote standardized management, the company implements9000Series standards, toGB/T19001-2000The standard is the core requirement to establish a quality management system and strengthen quality management. Our cable products have a mining safety mark certificate.

Copper wire shielding structure for mining control cablesCopper wire shielding structure for mining control cables


1Implementation standards for mining control cables:MT818-1999
2
Mining flame-retardant control cables are suitable for AC rated voltageu0/ufor450/750V The connecting wires of control monitoring circuits, protection circuits, and electrical instruments in the distribution equipment below.

3Mining control cable product model specifications and scope:

MKVV,MKVVP,MKVVP2 0.5-10mm2,2-61core

MKVV22,MKVV20 0.5-10mm2,4-61core

MKVV32,MKVV30 0.5-10mm2,7-61core

MKVVR 0.5-6mm2,2-61core

MKVVRP 0.5-4mm2,2-61core

MKVVP22,MKVVP2-22 1.5-10mm2,4-61core

MKVVP2-22-1 1.5-10mm2,4-61core

MKVV-1,MKVV22-1 0.5-10mm2,2-61core

4Usage: The long-term allowable working temperature of the control cable conductor used in coal mines is70The temperature for cable laying should not be lower than0The allowable bending radius for control cables used in coal mines: For cables with armor or copper tape shielding structures, it should not be less than the outer diameter of the cable12Twice. For flexible cables with a shielding layer structure, it should not be less than the outer diameter of the cable6Twice. For unarmored cables, the diameter should not be less than the outer diameter of the cable6times

Main products of the company

  The main products of Tianjin Cable Factory Rubber Cable Factory include mining rubber sheathed flexible cables, mining shielded cables, waterproof rubber sheathed flat cables, welding machine cables, mining drill cables, coal mining machine cables, high-voltage rubber sheathed cables, power cables, flame-retardant and fire-resistant power cables, control cables, and wiring. Its leading products have won the titles of provincial and ministerial excellence multiple times, and the "Yinshun" brand and trademark have won awards in Hebei Provincetitle. The mining series cables have been awarded the 'Safety Production Mark Certificate' by the enterprise.


National standard flame retardant ZR-DJYPRP shielded cable price

Product Details

Computer cable usage:This product is suitable for connecting electronic computers, testing instruments, and meters with high anti-interference performance requirements for rated voltages of 300/500V and below.

ZR-DJYPPP flame retardant shielded cable priceUsage conditions: The long-term working temperature of cable conductors is 70 ℃ and 105 ℃ for polyvinyl chloride; Polyethylene insulation at 70 ℃; Cross linked polyvinyl chloride insulation is 90 ℃. The cable is allowed to be fixedly laid and used under the condition of ambient temperature of -40 ℃ to 50 ℃, and the laying environment should not be lower than 0 ℃. 3. For cables with copper tape shielding structure, the bending radius during laying should not be less than 12 times the outer diameter of the cable, and for other cables, the bending radius during laying should not be less than 6 times the outer diameter of the cable.

DJYPV

Polyethylene insulated twisted copper wire braided shielded polyvinyl chloride sheathed computer cable

Laying indoors, cable trenches, pipelines, etc. requires electrostatic shielding

occasion

DJYVP

Polyethylene insulated twisted copper wire braided total shielding PVC sheathed computer cable

Laying indoors, cable trenches, pipelines, etc. requires electrostatic shielding

occasion

DJYPVP

Polyethylene insulated twisted copper wire braided shielded and total shielded PVC sheathed computer cable

Laying indoors, cable trenches, pipelines, etc. requires electrostatic shielding

occasion

DJYP2V

Polyethylene insulated twisted pair copper tape shielded polyvinyl chloride sheathed computer cable

Laying indoors, cable trenches, pipelines, etc. requires electrostatic shielding

occasion

DJYVP2

Polyethylene insulated twisted pair copper tape total shielding polyvinyl chloride sheathed computer cable

Laying indoors, cable trenches, pipelines, etc. requires electrostatic shielding

occasion

DJYP2VP2

Polyethylene insulated twisted pair copper tape shielded and total shielded polyvinyl chloride sheathed computer cable

Laying indoors, cable trenches, pipelines, etc. requires electrostatic shielding

occasion

Working temperature: generally not exceeding 70 ℃.
Zui low ambient temperature: fixed installation -40 ℃. Non fixed installation -15 ℃.
The general flame retardant performance meets the requirements of GB12666.2-90; The bundled flame retardant performance meets the requirements of GB-12666.5-90
Rated voltage: U0/U:300/500V.
The minimum bending radius for unarmored cables should not be less than 10 times the outer diameter of the cable; Armored cables should not be less than 12 times the outer diameter of the cable
ZR-DJYPVP cable priceMain technical indicators:

performance

unit

technical indicators



Polyethylene insulation

Polyvinyl chloride insulation




Insulation resistance at 20 ℃

Between any pair of conductors

MΩ.km

≥5000

-

Line to shield room

≥1

-



Working capacitor (1KHz)

Type 3

Pf/m

75

-

Type 1 and Type 2

90

-



Unbalanced capacitance (1KHz)

Pf/m

1

-


Inductance resistance ratio

0.75mm2
1.0mm2
1.5mm2

μH/Ω

≤20
≤25
≤35

≤20
≤25
≤30

Shielding inhibition coefficient

-

≤0.01

≤0.01


Test voltage

V/1min

1000

1000


flame retardancy

-

Meets the requirements of GB12666-90



National standard flame retardant ZR-DJYPRP shielded cable priceOur company solemnly declares that:
1. Sign a product quality assurance certificate and promise that unqualified products will never leave the factory.
2. Provide product quality tracking services within two years and keep customer service records in archives for 20 years.
3. Due to product quality issues, our company will provide warranty, return, replacement, and meet customer requirements.
Product specifications: Customized according to customer requirements
Product quantity: The minimum order quantity is 100 meters, and the price for 100-200 meters will increase
Packaging instructions: Packaged in trays with a length of meters, packaged in cable shafts with a length of meters
Price Description: The price is updated at any time based on the fluctuation of copper prices


ZR-KVV flame retardant 450/750V-30 * 6mm2 cable price including tax and shipping

Control cables [1] are suitable for PVC insulated and PVC sheathed control cables used in industrial and mining enterprises, power and transportation departments, and places where AC additional voltage below 450/750 volts is supplied, as well as nearby and protected lines.
● Model and name
KVV - Copper core PVC insulated and PVC sheathed control cable.
Execution scale of this product: GB/t9330.1-2008 and GB9330.2-88
KVVPL - Copper core PVC insulated, PVC sheathed aluminum foil control cable.
KVV 22- Copper core PVC insulated, PVC sheathed, steel tape armored control cable.
KVVRP - Copper core PVC insulated, PVC sheathed braided control flexible cable.
KVVP 2- Copper core PVC insulated, PVC sheathed copper tape control cable.
KVVP - Copper core PVC insulated, PVC textile control cable.
KVVR - Copper core PVC insulated and PVC sheathed control flexible cable.
●利用
Extra voltage: U0/U is 450/750V or 0.6/1KV
The long-term working temperature of the conductor core is 70 ℃ and 105 ℃, and the cable laying temperature is not lower than 0 ℃.
The allowable bending radius for cable lifting is as follows:
Unarmored cables should not be less than 6 times the outer diameter of the cable;
Armored or copper tape shielded cables should not be less than 12 times the outer diameter of the cable; Soft cables should not be less than 6 times the outer diameter of the cable.
Control cables generally refer to equipment instrument power supply/signal control
Representative model: KVV/KYJV/Other instrument lines, etc
ZR-KVV flame retardant 450/750V-30 * 6mm2 cable price including tax and shipping

How to prevent wires and cables from catching fire
1. Ensure construction quality, especially the production quality of cable heads, which must strictly comply with regulatory requirements.
2. Strengthen cable operation monitoring to avoid cable overload operation.
3. Conduct cable testing on schedule and promptly address any abnormalities found.
4. Cable trenches should be kept dry to prevent cables from getting damp, which can cause insulation degradation and short circuits.
5. Regularly clean the accumulated dust on the cable to prevent the dust from self igniting and causing the cable to catch fire.
6. Strengthen the regular calibration and maintenance of cable circuit switches and protections to ensure their reliable operation.
7. When laying cables, it is necessary to maintain sufficient distance from the heat pipe and control the cable to be no less than 0.5 meters; The power cable shall not be less than 1 meter. Control cables and power cables should be routed, layered, and arranged separately, without overlapping between layers. For parts that do not comply with regulations, flame-retardant and thermal insulation measures should be taken for cables.
8. Install fire alarm devices to promptly detect fires and prevent cable fires.
9. Take fire and flame retardant measures

Similar Product Recommend