3ch voltage standard [CH1: 0~+6V/200mA, CH2:0~+6V/30mA, CH3:0~+6V/30mA (universal)] has remote sensing function to compensate for the voltage drop at the output terminal. It is most suitable for VCO, other types of sensors, etc. The action test voltage resolution is 100 µ V (independently set for each channel) and the current readback resolution is 0.1 µ A. ※ (in standard mode) ※ The resolution within 200mA is 1 µ A, and the pulsation is below 100 µ Vrms. It supports high sensitivity equipment measurement and high visibility of current. 6-digit high-resolution instrument (no external ammeter required). Standard installation RS-232C, GPIB high-speed action current value refresh interval is 60ms (high-speed mode). The output connector comes with a D-SUB 25PIN lineup model specification KDS6-0.2TR 3ch that fully considers noise tolerance characteristics, with a set/read speed of 5ms (representative value in GPIB) Voltage standard [CH1: 0~+6V/200mA, CH2:0~+6V/30mA, CH3: 0~+6V/30mA (universal)], voltage resolution of 100 µ V (independently set for each channel), current readback resolution of 0.1 µ A ※ (in standard mode) ※ Resolution within 200mA is 1 µ A, pulsation is below 100 µ Vrms, supports high-sensitivity device measurement
Product Features
- 3ch voltage standard
[CH1: 0~+6V/200mA, CH2:0~+6V/30mA, CH3: 0~+6V/30mA (universal)]
- Equipped with remote sensing function to compensate for the voltage drop at the output terminal
- The most suitable action test for VCO, other types of sensors, etc
- Voltage resolution of 100 µ V (independently set for each channel)
- Current readback resolution 0.1 µ A ※ (in standard mode) ※ Resolution within 200mA is 1 µ A
- Pulsation below 100 μ Vrms, supporting measurement with high-sensitivity devices
- High visibility current 6-digit high-resolution instrument (no need for external ammeter)
- Standard installation RS-232C, GPIB
- High speed action
Current value refresh interval of 60ms (in high-speed mode)
Set/read speed of 5ms (representative value in GPIB)
- The output connector comes with a D-SUB 25PIN that fully considers noise tolerance characteristics
lineup
| model |
specifications |
|
KDS6-0.2TR
|
3ch voltage standard [CH1: 0~+6V/200mA, CH2:0~+6V/30mA, CH3: 0~+6V/30mA (universal)], voltage resolution of 100 µ V (independently set for each channel), current readback resolution of 0.1 µ A ※ (in standard mode) ※ Resolution within 200mA is 1 µ A, pulsation is below 100 µ Vrms, supports high-sensitivity device measurement |
PRODUCT FUNCTION
KDS6-0.2TR is designed for the production and testing lines of high-frequency components, ICs, LSIs, and sensors that have been operating at low voltage and low current consumption in recent years. This device is a DC stabilized power supply with low noise and high stability characteristics, with three channel outputs.