KX-HF4BRP Temperature Measurement Compensation Cable for Metallurgical Field

NegotiableUpdate on 11/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

KX-HF4BRP Metallurgical Temperature Measurement Compensation Cable - Manufacturing Compensation Cable Series Products: Glass Fiber Braided High Temperature Resistant Compensation Cable With its performance, it is widely used in high-temperature industrial equipment, high-temperature protection and corrosion resistance scenarios, power generation and energy systems, high-temperature control systems, metallurgy and steel industries, petrochemical industry, power and energy industry, mechanical manufacturing .....

Product Details

‌KX-HF4BRP‌冶金领域温度测量补偿电缆


Glass fiber braided high-temperature compensation cables are mainly used in the following fields due to their performance:


KX-HF4BRP Temperature Measurement Compensation Cable for Metallurgical Field Core purpose

  1. High temperature environment power transmission

    • Stable power transmission in high-temperature equipment, suitable for furnaces, electric heating equipment and other occasions, supporting long-term high-temperature operation

    • ‌KX-HF4BRP‌冶金领域温度测量补偿电缆

  2. Signal compensation and control

    • Cooperate with thermocouples, sensors and other instruments to compensate for temperature errors in signal transmission and ensure industrial automation control accuracy.

  3. High temperature protection and corrosion resistance scenarios

    • By using glass fiber weaving layer and silicone rubber insulation material, it can resist high temperature radiation, acid and alkali corrosion, and mechanical wear.


KX-HF4BRP Temperature Measurement Compensation Cable for Metallurgical Field

Typical usage scenarios

  1. High temperature industrial equipment

    • Areas such as glass plant furnaces, steel plant heating furnaces, and petrochemical plant reaction equipment that require continuous exposure to high temperatures of 300-600 ℃.

  2. Power generation and energy system

    • Power connection lines or signal transmission lines in high-temperature areas of thermal power generation units and nuclear power equipment.

  3. High temperature control system

    • Temperature monitoring of kilns, electrical connections for high-temperature baking equipment (such as paint baking rooms), and heat-resistant control circuits for automated production lines.

  4. Mobile devices and complex environments

    • Power lines for mobile equipment in high-temperature workshops, cables for high-temperature rolling mills in the metallurgical industry, and other applications that require frequent bending or mechanical stress.


IIIMain application industries

  1. Glass manufacturing industry

    • A power supply and temperature monitoring system for glass melting furnaces to meet the production needs of high-temperature molten glass.

  2. Metallurgy and Steel Industry

    • Power transmission and signal compensation for equipment such as steelmaking furnaces, continuous casting machines, and high-temperature rolling mills.

  3. Petrochemical industry

    • Power and control connections for corrosive and high-temperature environments such as refining units, reaction vessels, and high-temperature pipelines.

  4. Electricity and Energy Industry

    • High temperature cable laying in boiler areas of thermal power plants, cooling systems of nuclear power plants, and new energy equipment.

  5. Mechanical Manufacturing and Automotive Industry

    • Electrical support for automotive painting production lines, high-temperature testing equipment, and industrial kilns.


4Special scenario extension

  • Short term extreme high temperatureSpecial models (such as sintering process cables) can withstand a temperature of 1000 ℃ for a short period of time and are suitable for emergency equipment or sudden high temperature conditions
    .

  • Composite environmental protectionArmor models (such as steel strip/steel wire armor) can be used for complex industrial scenarios such as buried, high mechanical stress, or explosion-proof.

Note: Specific selection should be based on temperature level, shielding requirements, and industry standards. For example, fire-resistant models (ZR prefix) are suitable for places with high fire protection requirements

‌KX-HF4BRP‌冶金领域温度测量补偿电缆


temperature parameter

  1. Working temperature range

    • Long term applicable temperature: -40 ℃~+300 ℃ (conventional model)
      Some models can reach 500 ℃ or higher (requiring special sintering processes)
      .

    • Short term temperature resistance limit: Some models can withstand 600 ℃ to 1000 ℃ (for 90 minutes) in special situations
      .

  2. Laying temperature

    • Fixed installation environment not lower than -60 ℃ (fluoroplastic sheath model) or -25 ℃ (conventional model)
      .

Conductors and insulation materials

  1. Conductor material

    • We often use alloy wire or soft structure multi strand alloy wire (nickel plated copper is optional).

  2. Insulation layer structure

    • Inorganic mica tape wrapped insulation+glass fiber woven layer, or PTFE/fluoroplastic insulation.

    • Some models have added fire-resistant mica tape wrapping to improve temperature resistance performance2.

Sheath and shielding

  1. Sheath material

    • Glass fiber woven sheath (density up to 100%), partially coated with high-temperature resistant adhesive layer or sintered treatment on the outer layer.

  2. Shielding type

    • Optional tin plated copper wire, galvanized steel wire braided shielding, or composite aluminum/copper tape wrapped shielding.

Electrical and Mechanical Performance

  1. rated voltage

    • The standard model is 450/750V
      Some high specification models support 600/1000V
      .

  2. Bending radius requirement

    • Unshielded structure: not less than 10 times the outer diameter of the cable; Shielded structure: not less than 16 times the outer diameter

Application Features

  1. Match thermocouple type

    • Support compensation wires with equal scale numbers such as KX, KC, JX, SC, EX, NC, TX, etc
      .

  2. Special function models

    • Flame retardant type (ZR prefix), armored type (-22 steel strip armor/-32 steel wire armor).

Typical Model Example

  • KX-HF4BRP2-6 cores, alloy conductor, glass fiber sheath, suitable for environments ranging from -40 ℃ to+300 ℃

  • ABHBRPLong term temperature resistance at 200 ℃, short-term fire resistance at 1000 ℃, including 100% glass fiber woven layer
    .

  • HF4 seriesMica tape+glass fiber insulation, temperature resistance of 1000 ℃, suitable for high heat applications such as electric heating and petrochemicals
    .

Note: Specific parameters need to be confirmed according to the model and specifications provided by the manufacturer. Different application scenarios may have special requirements for temperature, shielding, etc.