E-mail
1211737395@qq.com
- Phone
-
Address
16th Floor, Building 1A, No. 18 Huashiyuan North Road, Donghu New Technology Development Zone, Wuhan
Hubei Daolijie Technology Co., Ltd
1211737395@qq.com
16th Floor, Building 1A, No. 18 Huashiyuan North Road, Donghu New Technology Development Zone, Wuhan
Aquaplore3 is a system designed specifically for users with small usage but strict production and quality requirements. Automatically monitor and trace your water production process and maintenance work to ensure consistent and compliant quality of your ultrapure water. Featuring a variety of clever and intelligent designs, we assist you in quickly completing complex calibration and correction tasks, saving unnecessary manpower and time, allowing you to focus on more important research work. Now you no longer have to compromise your management work due to resource limitations, and can easily have laboratory ultrapure water with compliant quality.
| Dimensions and Weight | |||
| size | H x W x D; 625 x 410 x 470 mm | ||
| packing weight | 40kg | ||
| Water inlet requirements | |||
| water source | Tap water inflow | ||
| traffic | ≥ 50 L/h | ||
| Conductivity (25 ° C) | < 2000 μS/cm | ||
| pressure | 1-5 Kg | ||
| temperature | 5-35 °C | ||
| free chlorine | < 1 ppm | ||
| PH value | 6.5-8.5 | ||
| Total hardness (as CaCO)3Calculation) | <450ppm | ||
| Electricity requirements | |||
| Electricity input | 100-240 VAC,50-60 Hz | ||
| system voltage | 24V DC | ||
| System power | 221W(max) | ||
| Noise level | < 50 dB | ||
| Product Series | A3-05-05/10-BE | A3-10-05/10-BE | A3-20-05/10-BE |
| water quality parameters | |||
| Ultra pure water resistivity (25 ° C) | 18.2MΩ•cm | 18.2MΩ•cm | 18.2MΩ•cm |
| Pure water conductivity * (25 ° C) | 1-5 μS/cm | 1-5 μS/cm | 1-5 μS/cm |
| Total Organic Carbon (TOC) * * (treated with DP-RO) | < 1-3 ppb | < 1-3 ppb | < 1-3 ppb |
| bacteria | < 0.1 CFU/ml | < 0.1 CFU/ml | < 0.1 CFU/ml |
| bacterial endotoxin | < 0.001 EU/ml | < 0.001 EU/ml | < 0.001 EU/ml |
| Particulate matter (>0.2um) | <1/ml | <1/ml | <1/ml |
| Inorganic ion removal rate | ≥99.5% | ≥99.5% | ≥99.5% |
| heavy metal ions | ≤ 0.1 ppb | ≤ 0.1 ppb | ≤ 0.1 ppb |
| Silicon removal rate | > 99% | > 99% | > 99% |
| Water quantity parameters | |||
| Secondary reverse osmosis water production (25 ° C) | 5L | 10L | 20L |
| Water intake for pure water/ultrapure water respectively | 10ml-99L, The value can be set arbitrarily, with an accuracy of ± 2ml within 500ml and ± 1% above 500ml | ||
| Water intake flow rate | 1-2L/min | ||
| Ultra pure aquatic water quantity*** | 5/10T | 5/10T | 5/10T |
| Water utilization rate | 60-80% | 60-80% | 60-80% |
| Purification technology | |||
| Tap Water Pre treatment | yes | yes | yes |
| Reverse osmosis (DP-RO) | yes | yes | yes |
| Ultra purification column | yes | yes | yes |
| Photo oxidation | 185/254nm UV | 185/254nm UV | 185/254nm UV |
| Ultrafiltration column | 6KD | 6KD | 6KD |
| 0.2um Terminal Filter (UF) | yes | yes | yes |
| *Under the condition of general municipal water supply and conductivity<1000 μ S/cm | |||
| **Under the condition of general municipal water supply and raw water TOC<1000ppb | |||
| ***Different depending on the inflow situation | |||